9.3 PT113PN - Profinet
The PT113PN instruments are state-of-the-art strain gage load cell signal digitisers with a Profinet
interface. This instrument is used for any type of weighing processes and force measurement including
tank and silo weighing, dynamic weighing, check weighing, filling, tension /compression force
measurement etc.
A sample GSDML file is available supplied together with the instrument to aid in setup.
For connections refer to 4.2.1 and the table below. For front panel annunciator explanation refer to
5.1.2.4 and 5.1.2.1.
Profibus-DP interface
This interface uses Profibus-DPV1
Usage
Interfacing with a PC or PLC
Data formats
Profinet
Baud rate
The Ethernet interface operates at 100Mbit, full
duplex, as required by Profinet.
Warning:
Connect the shield to the reference ground or shield pin of the power connector.
Warning:
Disconnect AzComT PC software after configuration for Profinet interfacing to function
correctly.
9.3.1.1 Programming and Calibration
PT113PB instruments are programmed and calibrated with AzComT. Analogue digitiser parameter
values are very important for better weighing performance. Please refer to 6.3.1.
9.3.1.2 Profinet Setup
Profinet set up is performed with AzComT software as described in section 6.3.4.3.
Select Gateway tab after connecting AzComT to the instrument.
Refer to the previous page (9.2.1.3) under Profibus for PLC configuration.
Profinet Data Structure
PT113PN Output to PLC Input
Communication consists of a message 3 Dwords in length.
Bitwise order of a Dword:
Dword
(R/W)
D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
D15 D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
1
st
Dword
Not in use
Not in use
2
nd
Dword
Default, 32 bits indicated weight, 32 bits other weight or status determined by the 3
rd
Dword
Calibration errors
Calibration process status
3
rd
Dword
Not in use
PT113PB error codes
Not in use
Op.
Mode
In
Zero
Gross
Net
MD
Read command response
Cmd
Flg