  Safety Instructions

  

 

Caution! 

Keep this device away from rain and moisture! 

 

Caution! 

Be careful with your operations. With a dangerous 
voltage you can suffer a dangerous electric shock 
when touching the wires! 

 

Health hazard! 

By operating an amplifying system, you can produce 
excessive sound pressure levels that may lead to 
permanent hearing loss.

 

 

This  device  has  left  our  premises  in  absolutely 
perfect  condition.  In  order  to  maintain  this 
condition  and  to  ensure  a  safe  operation,  it  is 
absolutely  necessary  for  the  user  to  follow  the 
safety instructions and warning notes written in this 
user manual. 
 
Damages  caused  by  the  disregard  of  this  user 
manual  are  not  subject  to  warranty.  The  dealer will 
not  accept  liability  for  any  resulting  defects  or 
problems. 
 
Unpacking 

• 

Please make sure that there are no obvious transport 
damages.  Should  you  notice  any  damages  on  the 
connection  panel  or  on  the  casing,  do  not  take  the 
speaker  system  into  operation  and  immediately 
consult your local dealer. 

• 

Keep  the  packaging.  To  fully  protect  the  device 
against 

vibration, 

dust 

and 

moisture 

during 

transportation or storage use the original packaging. 

Protection Class 

• 

This  device  falls  under  protection  class  I.  The  power 
plug  must  only  be  plugged  into  a  protection  class  I 
outlet. The voltage and frequency must exactly be the 
same  as  stated  on  the  device.  Wrong  voltages  or 
power outlets can lead to the destruction of the device 
and to mortal electrical shock.  

Power Cord 

• 

Always  plug  in  the  power  plug  least.  The  power  plug 
must always be inserted without force. Make sure that 
the plug is tightly connected with the outlet.  

• 

Never let the power cord come into contact with other 
cables!  Handle  the  power  cord  and  all  connections 
with  the  mains  with  particular  caution!  Never  touch 
them  with  wet  hands,  as  this  could  lead  to  mortal 
electrical shock.  

• 

Never modify, bend, strain mechanically, put pressure 
on, pull or heat up the power cord. Never operate next 
to  sources  of  heat  or  cold.  Disregard  can  lead  to 
power cord damages, fire or mortal electrical shock. 

• 

The cable insert or the female part in the device must 
never  be  strained.  There  must  always  be  sufficient 
cable  to  the  device.  Otherwise,  the  cable  may  be 
damaged which may lead to mortal damage.  

• 

Make  sure  that  the  power  cord  is  never  crimped  or 
damaged  by  sharp  edges.  Check  the  device  and  the 
power cord from time to time.  

 

• 

If  extension  cords  are  used,  make  sure  that  the  core 
diameter  is  sufficient  for  the  required  power 
consumption  of  the  device.  All  warnings  concerning 
the  power  cords  are  also  valid  for  possible  extension 
cords. 

• 

Always disconnect from the mains, when the device is 
not in use or before cleaning it. Only handle the power 
cord  by  the  plug.  Never  pull  out  the  plug  by  tugging 
the  power  cord.  Otherwise,  the  cable  or  plug  can  be 
damaged  leading  to  mortal  electrical  shock.  If  the 
power plug or the power switch is not accessible, the 
device must be disconnected via the mains. 

• 

If  the  power  plug  or  the  device  is  dusty,  the  device 
must  be  taken  out  of  operation,  disconnected  and 
then be cleaned with a dry cloth. Dust can reduce the 
insulation  which  may  lead  to  mortal  electrical  shock. 
More  severe  dirt  in  and  at  the  device  should  only  be 
removed by a specialist. 

Liquids 

• 

There  must never  enter  any  liquid  into  power  outlets, 
extension  cords  or  any  holes  in  the  housing  of  the 
device. If you suppose that also a minimal amount of 
liquid  may  have  entered  the  device,  it  must 
immediately be disconnected. This is also valid, if the 
device  was  exposed  to  high  humidity.  Also  if  the 
device is still running, the device must be checked by 
a  specialist  if  the  liquid  has  reduced  any  insulation. 
Reduced insulation can cause mortal electrical shock. 

Foreign Objects 

• 

There  must  never  be  any  objects  entering  into  the 
device.  This  is  especially  valid  for  metal  parts.  If  any 
metal  parts  like  staples  or  coarse  metal  chips  enter 
into  the  device,  the  device  must  be  taken  out  of 
operation  and  disconnected  immediately.  Malfunction 
or  short-circuits  caused  by  metal  parts  may  cause 
mortal injuries. 

Avoiding Hum 

• 

Never  install  the  amplifier  next  to  highly  sensitive 
devices  like  pre-amplifiers  or  tape-decks,  as  the 
strong  magnetic  field  of  the  amplifier  can  produce 
hum in these devices. The magnetic field is strongest 
directly above or below the amplifier. If a rack is used, 
the amplifier should be installed at the bottom and the 
highly sensitive devices at the top. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

18 

Содержание DDA-1700

Страница 1: ...G S A N L E I T U N G B E D I E N U N G S A N L E I T U N G B E D I E N U N G S A N L E I T U N G B E D I E N U N G S A N L E I T U N G U S E R M A N U A L U S E R M A N U A L U S E R M A N U A L U S...

Страница 2: ......

Страница 3: ...3 die PA Endstufen...

Страница 4: ...greiche Schutzschaltungen gesch tzt Die Merkmale im berblick Stereo PA Verst rker in Class D Technologie Geringes Gewicht und Bauh he durch integriertes Schaltnetzteil Zuverl ssiges Arbeitsger t mit h...

Страница 5: ...Produkts 2017 PSSO Alle Rechte vorbehalten Dieses Dokument darf ohne schriftliche Genehmigung des Copyrightinhabers weder ganz noch teilweise reproduziert werden Der Inhalt dieses Dokuments kann ohne...

Страница 6: ...s zu t dlichen Stromschl gen f hren kann Achten Sie darauf dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm...

Страница 7: ...das Ger t nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelger t entfernt betrieben wird Der Raum darf nur so stark mit Nebel ges ttigt sein dass eine gute Sichtweite von...

Страница 8: ...115 dB A bei einem Rockkonzert Einzelne Pegelspitzen k nnen die Schmerzgrenze berschreiten die bei 130 dB A liegt Solche Werte sind typisch f r den Betrieb einer Motorkettens ge oder eines Pressluftha...

Страница 9: ...n und aus 4 Netzanschluss Der Verst rker besitzt ein internes Netzteil welches Spannungen von 100 240 V und Frequenzen von 50 60 Hz akzeptiert Ein passendes Netzkabel ist inbegriffen 5 Lautsprecherans...

Страница 10: ...precher mit einem zweipoligen Speaker Stecker an die Buchsen an Achten Sie beim Zusammenschalten von mehreren Lautsprechern besonders auf die richtige Polung und darauf dass die Gesamtimpedanz im Mehr...

Страница 11: ...egel an Bei bersteuerung leuchtet die Anzeige CLIP Reduzieren Sie dann die Lautst rke entsprechend Im Br ckenbetrieb ist der Laust rkeregler f r Kanal 2 deaktiviert Der Pegel l sst sich mit dem Lautst...

Страница 12: ...rst rkung 38 2 dB 39 7 dB 41 2 dB Eingangsimpedanz 20 k symmetrisch 10 k unsymmetrisch Anschluss Eingang 4 x XLR Anschluss Ausgang 4 x Speaker 4 x XLR Durchschleifausgang Schaltung Class D Schutzschal...

Страница 13: ...b Parallelbetrieb Kanal 1 Stereobetrieb Parallelbetrieb Kanal 2 Br ckenbetrieb Kanal 1 13 2 1 3 1 2 3 Symmetrische XLR Verbindung 1 Masse Schirm 2 Plus Phase 3 Minus Phase Eingang Ausgang Um eine XLR...

Страница 14: ......

Страница 15: ...15...

Страница 16: ...d through extensive protective circuits Overview of all features Stereo PA amplifier with class D circuitry Low weight and height due to integrated switch mode power supply Reliable power amp with hig...

Страница 17: ...2017 PSSO All rights reserved No part of this document may be reproduced in any form without the written permission of the copyright owner The contents of this document are subject to revision withou...

Страница 18: ...be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to mortal damage Make sure that the power cord is never crimped or damaged by sharp e...

Страница 19: ...ice is never exposed to the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and device Incorrect Operation Operate the device only after having familiarized with it...

Страница 20: ...amplification systems should know to what sound pressure levels he exposes his or the audience s hearing As an average levels between 75 and 105 dB A in the discotheque or 95 and 115 dB A at a rock co...

Страница 21: ...s the amplifier on and off 4 Power input The amplifier has an internal power supply that will accept voltages ranging from 100 240 V at frequencies from 50 60 Hz A power cord is included 5 Speaker out...

Страница 22: ...nect the speakers with a two pole Speaker jacks When connecting multiple speakers always observe the correct the polarity and make sure that the total impedance is at least 2 in multi channel mode or...

Страница 23: ...input level In case of overload the red CLIP indicator lights up In this case reduce the volume correspondingly In bridge mode the level controls for channel 2 and channel 4 are disabled Volume adjus...

Страница 24: ...gain 38 2 dB 39 7 dB 41 2 dB Input impedance 20 k balanced 10 k unbalanced Input connectors 4 x XLR Output connectors 4 x Speaker 4 x XLR feed trough output Circuitry Class D Protection circuits soft...

Страница 25: ...ctors Stereo operation parallel operation CH 1 Stereo operation parallel operation CH 2 Bridge operation CH 1 25 25 2 1 3 1 2 3 Balanced use with XLR connectors 1 Ground Shield 2 Hot 3 Cold For unbala...

Страница 26: ......

Страница 27: ......

Страница 28: ...PSSO is a brand of Steinigke Showtechnic GmbH I Andreas Bauer Str 5 I 97297 Waldb ttelbrunn Germany...