Quick Start PSS MCX GPC/SEC Columns 

1. Introduction

Thank you for choosing a PSS MCX column. It is a high quality, high performance product ready for 
immediate use. This 

Quick Start Guide

 is designed to get the user up and running quickly with the 

common, compatible solvents.  
For detailed information on care and use in a wide range of solvents, replacement parts and 
accessories, download the 

Full User’s Guide

:  

www.pss-polymer.com/Resources/manuals/FullUsersGuide_MCX_E.pdf 

PSS MCX columns are packed with highly porous particles of a sulfonated styrene-divinylbenzene 
copolymer and are supplied as standard in water with 0.75mmol sodium azide. Each column has a 
unique serial number and is quality checked for efficiency in the eluent in which the column was 
ordered. The test conditions and results are shown on the enclosed certificate of analysis (CoA). 
Please keep this in a safe place for future reference. 

1.1 Specifications 

Column Type 

Max. Operating 
Pressure  
per column  
bar / psi  

Max. Operating 
Pressure for  
3 Column Set  
bar / psi 

Max. 
Operating 
Temperature 

Efficiency 
Plates/m 
Dextran p1 in 
water 0.75mmol 
NaN

3

 

MCX 5µ 

60 / 870 

120 / 1740 

80°C 

>40.000

MCX 10µ 

40 / 580 

80 / 1160 

80°C 

>20.000

MCX Prep 

40 / 580 

80 / 1160 

80°C 

>15.000

1.2 Solvent Compatibility 

PSS MCX is compatible with a wide range of aqueous eluents and has optimum performance, when 
used with eluents, which have a pH in the range 7.0 to 13.0 for the analysis of sulfonated polyanions. 
Transfer to compatible eluents is easy provided the guidelines in this user manual are followed. For 
solvents outside this pH range, other PSS column materials may be more appropriate to maintain a 
balance between sample ionic character, eluent pH and packing material polarity for a size only based 
separation based on the 

Magic Triangle

 concept. Please visit th

PSS website

 for more information. 

Parameter 

Range 

Comment 

pH Stability 

1-13

Chemical stability 

Optimum pH range 

7-13

Due to anionic nature of the surface 

Temperature 

<80°C 

Operate at 10°-35°C for optimum column lifetime 

Organic modifiers 

<100% v/v 

e.g Methanol, Acetonitrile, Tetrahydrofuran

Salts 

< 0.5M 

e.g.NaN

3

, NaCl, NaNO

3

Buffers 

Compatible with most commonly used buffers 

2. Column Installation

When using the column for the first time it is recommended to use the eluent that the column was 
originally supplied in and to perform a system plate count noting the backpressure. However, this is 
not essential. 

2.1 Preparing the GPC/SEC system 

Remove any existing columns and store according to the manufacturer’s instructions. Connect the 
injector directly to the detector with appropriate tubing and connectors. Transfer the GPC/SEC system 
from the current eluent to that required, paying attention to the miscibility and compatibility with the 
hardware as per the manufacturer’s instructions.

 