3. AC Utility Failure 

If AC utility fails, the UPS quickly detects the problem and activates the 

inverter. The inverter. The DC/AC inverter changes DC power from the 

batteries into AC and provides continuous uninterruptible power to load.

 

AVR.

INV.

CHA.

N.F.

N.F.

INPUT

OUTPUT

 

Fig. 3 shows how the UPS works when AC Utility Failure

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 4 -

 

 

COMPUTER INTERFACE 

The  computer  interface  (DB9  port)  on  the  back  of  the  UPS  may  be 
connected to a host computer. This port allows the computer to monitor the 
status of the UPS and control the operation of the UPS. The UPSilon-2000 
((option),M2502 Cable), provides complete On-Screen power management 
to  the  UPS  and  computer  systems.  Its  major  functions  normally  include 
some or all the following: 

 

Real-time UPS status on screen. 
All history records in memory. 
Auto orderly shutdown for computer & UPS. 
Multi-server support. 
Auto file save even without filename preset. 
Scheduled switch on/off daily or weekly.

 

 
Pin out information: 

 

PIN# 

Description 

I/O 
Input 
Output 

Output 

PIN1 
PIN2 
PIN3 
PIN4 
PIN5 
PIN6 

RS232 DTR, must keep in high state 
Line fail, normally open, active close 
N.C. 
Common for PIN 2,5 
Battery low, normally open, active close 
Two purposes on this pin 
(1)Remote shut down, keep this pin high 

(+5~+12V) for 3S will turn off the UPS 

(2)RS232 Receiver Rx 

Input 

PIN7 

Ground for PIN 6,9 

 

PIN8 

N.C. 

 

PIN9 

RS232 Transmitter TX 

Output 

1

2

3

4

5

6

7

8

9

D-SUB 9 Pin Female Connector

Signal High Min. 3 Second

Contacts
Normally
Open

Low Battery
Mains Failure

Common

or RS232 RX

RS232 DTR

RS232 TX

Pin Number

UPS Shut Down

1

2

3

4

5

6

7

8

9

 

- 9 -

 

Содержание ECO-220

Страница 1: ...h Computer Loads Only Intelligent Auto Shutdown Software Power Surge Noise Protection Internet Line Protection Cost Efficiency AVR Protection Compact Reliable Design U US SE ER R S S M MA AN NU UA AL...

Страница 2: ...ife that the UPS has to offer Please save this manual It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into...

Страница 3: ...previous power failure Recharge the battery for at least 6 hours re test the backup time If problem remains call for service 12 CAUTION The UPS contains voltages that are potentially hazardous All rep...

Страница 4: ...ery life is significantly shortened Every 90 days remove the unit from storage and plug it in for 24 hours to recharge the batteries Batteries may be damaged if left in storage and not recharged every...

Страница 5: ...t is designed to sound an alarm every 3 seconds and with BACK UP LCD light on when simulation starts If the CUT OFF LCD is on it means UPS fault or BATTERY fault Then you have to contact your local se...

Страница 6: ...UPS being fitted with additional Battery Bank for extending back up time 1 Connect AC Main Power under UPS machine in no load condition 2 To make sure Battery group voltages are same as DC BUS voltag...

Страница 7: ...en AC recovery Cold start function Dip switch setup Tel Modem Fax Internet surge suppression Option Bundle software Automatically save your valuable files before auto shutdown 2 SPECIFICATIONS Model E...

Страница 8: ...11...

Страница 9: ...normally include some or all the following Real time UPS status on screen All history records in memory Auto orderly shutdown for computer UPS Multi server support Auto file save even without filenam...

Страница 10: ...8 9 0 25 50 75 100 co 6 Rear Panel IEC 320 AC INPUT IN OUT INTERNET REMOTE AC FUSE 1 2 3 Dc start ON Noloadauto shutdownON Buzzer auto reset ON CAUTION RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER 5 1 3...

Отзывы: