PSH MAXI 15 M Скачать руководство пользователя страница 5

GB

The pipes should be fitted in such a way that any pressure variation caused by temperature
changes do not to affect the pump.

If the piping is very long, it must be suitably supported in front of and behind the pump and
it is best to place a retention or anti-hydraulic ram valve in the drive.

The plastic pipes and connections should be screwed carefully.

If a hose is used in suction, it must be non-compressible (with a reinforcement spiral).

The suction pipe/hose must be as short as possible to assure optimum working conditions.

It is recommended to install close valves on either side to isolate the pump.

Note:

The pump does not allow work with a closed discharge valve as it may cause an in-

crease in the temperature and steam formation which can damage the pump.

If there is any danger of the pump working against a closed discharge valve, a by-pass/purg-
ing valve must be connected in a discharge pipe to ensure minimum liquid flow through the
pump.

To minimise possible noise from the pump, it is recommendable to install an anti-vibrator in
the suction and drive inlets and between the base plate and the pump.

According to the IEC no. 364 publication, the pump must be installed at least 2 m from
the swimming pool edge.

Make sure that the electrical supply is turned off before removing the connection box
cover or before any moving or disassembling of the pump.

The electrical connections must be performed by an authorised electrician and according to
the local standards.

The pump must be connected to an external switch.

The voltage and the frequency are marked on the characteristics plate. Make sure that the
motor is suitable for the electrical supply in use.

The motor must be connected to the electrical supply as shown in the drawing, using an ap-
proved, watertight cable and in accordance with local standards.

4

Electrical connections

3.1 Ventilation

The pump motor is cooled by the fan on the rear. We will therefore preferably place the pump
in a WELL VENTILATED place (protected from possible freezing), preferably in a room.

a) If the pump is installed OUTDOORS, it must be protected from the rain and the elements

with a suitable cover.

b) If the pump is installed in an underground or semi buried plant housing, a SUFFICIENT AIR

ENTRY must be assured for the motor ventilation in order to not be damaged (the inside
temperature should not exceed 50ºC).

c) In order to assure efficient  cooling , the minimum distance between fan cover and the wall

or another obstacle situated  at the  back side of the motor must be more than 2,5 times
than the fan diameter.

Instruction Manual for Series MAXI

Содержание MAXI 15 M

Страница 1: ...serie MAXI Instructions for use and maintenance...

Страница 2: ...entry of water through the electrical cable Pay attention on the cable position in order to prevent water seeping into the terminal box INCORRECT Daily cleaning of the prefilter basket In order to av...

Страница 3: ...details MAXI model pumps are of centrifugal type with a horizontal construction and auto suction capacity Their main application is to rotate the water in the swimming pool and they are normally in st...

Страница 4: ...ver on the top It must be possible to remove the transparent cover to take out the pre filter basket for cleaning The suction pipe must have at least the same diameter as the pump suction inlet diamet...

Страница 5: ...rom the swimming pool edge Make sure that the electrical supply is turned off before removing the connection box cover or before any moving or disassembling of the pump The electrical connections must...

Страница 6: ...ctly primed when the water is just below the transparent cover The arrows on the pump housing indicate the correct rotation In order to create maximum suction capacity when starting close the discharg...

Страница 7: ...Check the pre filter basket Tighten thumb screws of the lid equally 5 The suction is too high The maximum height allowed is 3m 6 The sum of the load losses from the installation exceeds the pumping ca...

Страница 8: ...Dimensions Type MAXI 15 M T MAXI 20 M T MAXI 30 T MAXI 40 T L 675 675 700 700 Dimensions...

Страница 9: ...phase cable bolt 32 Terminal box gasket 38 Terminal box cover gasket 41 Nut capsule 43 Pump side motor seal 44 Fan side motor seal 47 Terminal plate washer 50 Drip washer 53 Filter pump housing washe...

Страница 10: ...ew 37 Fan clamp 40 Complete press cable 44 Fan side motor seal 47 Terminal plate washer 49 Cable passage gasket 53 Filter pump housing washer 55 Impeller 57 Impellernut 58 Diffusser 61 Pump housing ga...

Отзывы: