PSG Wilden P8 Series Скачать руководство пользователя страница 13

 

WIL-10184-E-03  

13 

P8 Clamped Metal 

 

 

NOTE:

 In the event of a power failure, close the shut- 

off valve if you do not want the pump to restart when the 
power returns.

 

 

Air-Operated Pumps:

 To stop the pump from operating in an 

emergency, simply close the shut-off valve (user-supplied) installed in 

the air supply line. A properly functioning valve will stop the air supply 
to the pump, therefore stopping output. This shut-off valve should be 
located far enough away from the pumping equipment such that it can 

be reached safely in an emergency. 
 

Operation 

The Pro-Flo pumps are pre-lubricated and do not require in- line 
lubrication. Additional lubrication will not damage the pump. 
However, if the pump is heavily lubricated by an external source, the 

pump’s internal lubrication maybe washed away. If the pump is then 
moved to a nonlubricated location, it may need to be disassembled 

and re-lubricated as described in “Disassembly/ Reassembly”. 
 

Pump discharge rate can be controlled by limiting the volume and/or 
pressure of the air supply to the pump. An air regulator is used to 

regulate air pressure. A needle valve is used to regulate volume. 
Pump discharge rate also can be controlled by throttling the pump 
discharge by partially closing a valve in the discharge line of the 

pump. This action increases friction loss, which reduces flow rate. 
(See “Performance”) This is useful when the need exists  

 

 

to control the pump from a remote location. When the pump 
discharge pressure equals or exceeds the air supply pressure, the 

pump will stop. No bypass or pressure relief valve is needed, and 
pump damage will not occur. The pump has reached a “deadhead” 
situation and can be restarted by reducing the fluid discharge 

pressure or increasing the air inlet pressure. Wilden Pro-Flo pumps 
run solely on compressed air and do not generate heat. 

Therefore, your process fluid temperature will not be affected. 
 

Maintenance and Inspections 

Because each application is unique, maintenance schedules maybe 

different for every pump. Frequency of use, line pressure, viscosity 
and abrasiveness of process fluid all affect the parts life of a Wilden 

pump. Periodic inspections have been found to offer the best means 
for preventing unscheduled pump downtime. Personnel familiar with 

the pump’s construction and service should be informed of any 
abnormalities that are detected during operation. 
 

 

 

SUGGESTED INSTALLATION, OPERATION, MAINTENANCE  

AND TROUBLESHOOTING 

Содержание Wilden P8 Series

Страница 1: ...WIL 10184 E 03 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL P8 Clamped Metal Pump...

Страница 2: ...lifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are regis...

Страница 3: ...al TPE Fitted 8 P8 Metal Reduced Stroke PTFE Fitted 9 P8 Metal Full Stroke PTFE Fitted 9 P8 Metal Ultra Flex Fitted 10 Suction Lift Capability 11 SECTION 6 Suggested Installation Operation Maintenance...

Страница 4: ...he pump s rated solids capacity is not exceeded CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION The process fluid and cleaning fluids must be chemically compatible with all wetted p...

Страница 5: ...E DOT WF WIL FLEX SANTOPRENE THREE BLACK DOTS VALVE SEATS A ALUMINUM BN BUNA N RED DOT EP EPDM BLUE DOT FS SANIFLEX HYTREL CREAM FW SANITARY WIL FLEX 1 3 SANTOPRENE TWO BLACK DOTS H ALLOY C M MILD STE...

Страница 6: ...manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump disc...

Страница 7: ...3 13 5 K 231 9 1 L 257 10 1 M 257 10 1 N 312 12 3 P 15 0 6 R 64 2 5 S 51 2 0 T 282 11 1 U 58 2 3 V 279 11 0 W 396 15 6 X 15 DIA 0 6 DIA LW0395 REV A P8 Metal Saniflo FDA DIMENSIONS ITEM METRIC mm STAN...

Страница 8: ...ll in the center of the pump s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure P8 METAL TPE FITTED Ship Weights Aluminum 32 kg 70 lb Stainless Steel 51 kg 112 lb Cast Iron...

Страница 9: ...will fall in the center of the pump s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure P8 METAL FULL STROKE PTFE FITTED Ship Weights Aluminum 32 kg 70 lb Stainless Steel 5...

Страница 10: ...mm 1 4 1Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 1 bar 30 psig head pressure Example To pump 201 lpm 53 gpm against a discharge pressure head of 2 1 bar...

Страница 11: ...000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping...

Страница 12: ...trokes per minute and then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other muffler...

Страница 13: ...to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss which...

Страница 14: ...unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift li...

Страница 15: ...ware of any hazardous effects of contact with your process fluid NOTE Your specific pump model may vary from the configuration shown however pump disassembly procedure will be the same NOTE Replace wo...

Страница 16: ...ke valve balls and seats Inspect ball cage area of liquid chamber for excessive wear or damage Step 7 Step 8 Step 9A Remove one 1 set of large clamp bands which secure one 1 liquid chamber to the cent...

Страница 17: ...e liquid chamber Inspect diaphragm assembly and shaft for signs of wear or chemical attack Replace all worn parts with genuine Wilden parts for reliable performance To remove diaphragm assembly from s...

Страница 18: ...d Wrench 1 4 Hex Head Wrench Snap Ring Pliers O Ring Pick CAUTION Before attempting any maintenance or repair disconnect the compressed air line to the pump and allow all air pressure to bleed from th...

Страница 19: ...ion when handling air valve spool to prevent damaging seals Remove pilot spool sleeve retaining snap ring on both sides of center section with snap ring pliers NOTE Seals should not be removed from as...

Страница 20: ...re assembly never insert the pilot spool into the sleeve with the notched end first this end incorporates the urethane O ring and will be damaged as it slides over the ports cut in the sleeve NOTE Se...

Страница 21: ...ft seals A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly Make sure that the exhaust port on the muffler pla...

Страница 22: ...th the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the clamp...

Страница 23: ...he adhesive covering from the back of the PTFE tape Ensure that the adhesive strip remains attached to the PTFE tape Starting at any point place the PTFE tape in the center of the diaphragm bead groov...

Страница 24: ...WIL 10184 E 03 24 P8 Clamped Metal SECTION 8 P8 FULL STROKE DIAPHRAGM FITTED EXPLODED VIEW AND PARTS LIST ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS...

Страница 25: ...Pilot Spool Retaining O Ring 2 04 2650 49 700 04 2650 49 700 04 2650 49 700 04 2650 49 700 15 Shaft Seal 2 08 3210 55 225 08 3210 55 225 08 3210 55 225 08 3210 55 225 16 Gasket Center Block Pro Flo 2...

Страница 26: ...WIL 10184 E 03 26 P8 Clamped Metal P8 METAL SANIFLO 1925 2004 EC EXPLODED VIEW AND PARTS LIST...

Страница 27: ...0 99 13 O Ring 009 PilotSpoolRetaining 208 x 070 2 04 2650 49 700 14 Seal Shaft 2 08 3210 55 225 15 Gasket Center Block Pro Flo 2 04 3526 52 16 Air Chamber Pro Flo 2 08 3651 01 17 Screw HSFHS 3 8 16 x...

Страница 28: ...52 N A 08 1080 52 08 1120 52 N A EPDM 08 1010 54 08 1020 54 08 1060 54 08 1080 54 08 1120 54 N A FKM 08 1010 53 08 1020 53 N A 08 1080 53 08 1120 53 N A Saniflex 08 1010 56 N A 08 1060 56 08 1060 56...

Страница 29: ...WIL 10184 E 03 29 P8 Clamped Metal...

Страница 30: ...WIL 10184 E 03 30 P8 Clamped Metal NOTES...

Страница 31: ...WIL 10184 E 03 31 P8 Clamped Metal NOTES...

Страница 32: ...USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non co...

Отзывы: