WIL-11113-E-04
Wilden
®
19
Disassembly / Reassembly
Step 15
Remove air valve end cap to expose air
valve spool by lifting up on end cap.
Inspect O-ring on end cap using an O-
ring pick. Replace O-ring(s) if necessary.
NOTE: The Pro-Flo
®
SHIFT air valve
incorporates an end cap at both ends of
the air valve,
Step 16
Remove the air valve spool from the air valve body by threading one air valve bolt into the end of the air
valve spool and gently sliding the spool out of the air valve body. Inspect seals for signs of wear and
replace the entire air valve assembly if necessary. Re-insert the spool immediately into air valve body after
inspection as the seals expand and cannot be reinserted after a length of time.
NOTE: Seals should not be removed from the assembly. Seals are not sold separately.
SINGLE - POINT EXHAUST PRO - FLO
®
SHIFT
Step 1
Remove pilot exhaust muffler in pilot
bleed port located at the front of the
center block. Install 1/4" NPT pipe plug
(00-7010-08) into bleed port.
Step 2
Next, install an optional single-point exhaust air valve
gasket (04-2638-52). The single-point air valve gasket can
be purchased as a spare part or included with the purchase
of a new Pro-Flo
®
SHIFT pump.