PSG PA08550 Скачать руководство пользователя страница 2

This option can be installed on either side of your Max Caddy furnace.  

It is important to note that this option requires a 60 gallons buffer tank. 

 
 

For installation on the right hand side, follow steps 1 to 5 of section 1. 

For installation on the left hand side, follow steps 1 to5 of section 2.   

 

Section 1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short bracket

Screw

Step  1:  Remove  the  screw 

located  on  the  left  of  the 

assembly  as  shown  on 

figure 1.  Keep this screw to 

install  the  “short”  bracket 

supplied in the hardware kit 

as per figure 2.  

INSTALLATION OF THE HOT WATER LOOP KIT FOR PRE-HEATING OF DOMESTIC 

WATER ON THE RIGHT HAND SIDE 

Figure 1   

Figure 2  

Содержание PA08550

Страница 1: ...45392A 05 06 2015 INSTALLATION OF THE OPTIONAL HOT WATER LOOP KIT FOR PRE HEATING OF DOMESTIC WATER PA08550 MAX CADDY FURNACE...

Страница 2: ...5 of section 1 For installation on the left hand side follow steps 1 to5 of section 2 Section 1 Short bracket Screw Step 1 Remove the screw located on the left of the assembly as shown on figure 1 Ke...

Страница 3: ...igure 3 and save the screws for step 5 Step 3 Slide the hot water loop assembly into the furnace between the firebox and the heat exchangers It is important that the assembly be centered on the top of...

Страница 4: ...mmets 2x Cut view showing position of the hot water loop above the fire box Figure 5 Step 4 Remove the knock outs from the right side panel and install the grommets in the holes as shown on figure 6 F...

Страница 5: ...panel to the furnace using the screws removed in step 2 Figure 7 Identify the water inlet lowest tube and outlet highest tube for installation purposes Figure 8 Diagrams for the hot water loop kit mec...

Страница 6: ...ted on the left of the assembly as shown on figure 9 Keep this screw to install the Long bracket supplied in the hardware kit as per figure 10 INSTALLATION OF THE HOT WATER LOOP KIT FOR PRE HEATING OF...

Страница 7: ...re 11 and save the screws for step 5 Step 3 Slide the hot water loop assembly into the furnace between the firebox and the heat exchangers It is important that the assembly be centered on the top of t...

Страница 8: ...ew of the inside of the furnace with the hot water loop kit centered above the firebox Figure 13 Step 4 Remove the knock outs from the left side panel and install the grommets in the holes as shown in...

Страница 9: ...the furnace using the screws removed in step 2 Figure 15 Identify the water inlet lowest tube and outlet highest tube for installation purposes Figure 16 Diagrams for the suggested hot water loop kit...

Страница 10: ...C T IN G T H E F U R N A C E T O T H E B U F F E R T A N K C O LD W A T E R S U P P LY T E M P E R IN G T A N K 2 10F 12 0LB S O N E W A Y V A LV E P R E S S U R E G A G E R E L IE F V A LV E D R A I...

Страница 11: ...VE ON THE INLET OF THE HOT WATER LOOP KIT TO PREVENT COLD WATER FROM CIRCULATING IN THE FURNACE WHEN NOT IN USE CONNECT THE VALVE TO THE WATR SOLN PORT LOCATED ON THE LEFT SIDE IN THE FURNACE S CONTRO...