![PSG Caddy PF01010 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/psg/caddy-pf01010/caddy-pf01010_installation-and-operating-instructions-manual_1622649007.webp)
7
1.1 INTRODUCTION
Take note that this furnace uses the same wood burning technology as a high
efficiency EPA certified wood burning stove. This applies to the lighting, the
ember bed, and the minimum combustion air intake which was calibrated to burn
good seasoned cordwood.
This model line is certified as meeting the emissions limits in 40 C.F.R. part 60,
section 60.532 (B) per EPA methods 28 and 5G-3, February 1988.
To optimize the efficiency of your furnace, here is some advice that you should
follow when installing or operating your CADDY furnace:
Respect the local codes (when in doubt, consult your local dealer);
Verify the specifications on the certification plate concerning the clearances to
combustibles making sure that they correspond to the ones included in this
instruction manual.
Make sure your furnace is installed according to the instructions on the
certification label;
All controls and adjustments must be performed by a qualified technician. The
blower speed must conform to the recommendations of the Warm Air Heating
and Air Conditioning National Association and should respect the static
pressure ranges in the warm air plenum of the furnace (see
section 3.1.7
,
General technical data, static pressure).
We recommend that our woodburning hearth products be installed and
serviced by professionals who are certified in the United States by NFI
(National Fireplace Institute®) or in Canada by WETT (Wood Energy
Technical Training) or in Quebec by APC (Association des Professionnels du
Chauffage).
Emissions: 6.6 g/h or 0.229 g/MJ
Average efficiency: 76 % (LHV) / 71% (HHV)
Содержание Caddy PF01010
Страница 16: ...16 CADDY ADD ON Installation Instructions CADDY WOOD ADD ON PF01010 PA08522 ...
Страница 21: ...21 CADDY ADD ON Option 1 Option 2 Minimum duct size 260 square inches R Minimum radius 6 inches ...
Страница 22: ...22 CADDY ADD ON Example 1 Example 2 ...
Страница 24: ...24 CADDY ADD ON Figure 3 1 4 3 a ...
Страница 30: ...30 CADDY ADD ON ...
Страница 34: ...34 CADDY ADD ON 3 1 6 4 WIRING DIAGRAM FOR CONNECTION OF THE CADDY ADD ON WITH AN EXISTING OIL FURNACE ...
Страница 38: ...38 CADDY WOOD ONLY Installation instructions for CADDY WOOD ONLY FURNACE PF01010 PA08568 PA00500 ...
Страница 40: ...40 CADDY WOOD ONLY ...
Страница 42: ...42 CADDY WOOD ONLY Figure 3 2 2 3 a ...
Страница 52: ...52 CADDY WOOD ELECTRIC Figure 3 3 3 3 a ...
Страница 55: ...55 CADDY WOOD ELECTRIC OUTSIDE VIEW OF THE ELECTRIC UNIT ...
Страница 62: ...62 CADDY WOOD ELECTRIC 3 3 4 5 WIRING DIAGRAM Refer to electric diagram included with the electrical unit ...
Страница 64: ...64 Installation instructions for CADDY WOOD OIL COMBINATION FURNACE PF01010 PA08568 PA03050 ou PA03100 ...
Страница 68: ...68 Figure 3 4 4 3 a ...
Страница 70: ...70 ...
Страница 73: ...73 Wiring diagram for Riello Burner ...
Страница 86: ...86 Cut view of the Caddy wood only furnace ...