PSG Dover WILDEN SANIFLO PS15 Hygienic Series Скачать руководство пользователя страница 6

 

WIL-12630-E-04

 

Wilden

® 

 

 
The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern 

through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE  1 

The air valve directs 

pressurized air to the back side of 

diaphragm A. The compressed air is 

applied directly to the liquid column 

separated by elastomeric diaphragms.  

The diaphragm acts as a separation 

membrane between the compressed air 

and liquid; a balanced load removes 

mechanical stress from the diaphragm. 

The compressed air moves the diaphragm 

away from the center of the pump. The   

opposite diaphragm is pulled in by the 

shaft connected to the pressurized 

diaphragm. Diaphragm B is on its suction   

stroke; air behind the diaphragm has been 

forced out to atmosphere through the 

exhaust port of the pump. The movement 

of diaphragm B toward the center of the 

pump creates a vacuum within chamber B. 

Atmospheric pressure forces fluid into the 

inlet manifold forcing the inlet valve ball off 

its seat. Liquid is free to move past the 

inlet valve ball and fill the liquid chamber 

(see shaded area).

 

FIGURE 2 

When the pressurized 

diaphragm, diaphragm A, reaches the limit 

of its discharge stroke, the air valve 

redirects pressurized air to the back side of 

diaphragm.  The pressurized air forces 

diaphragm B away from the center while 

pulling diaphragm A to the center. 

Diaphragm B is now on its discharge stroke. 

Diaphragm B forces the inlet valve ball onto 

its seat due to the hydraulic forces 

developed in the liquid chamber and 

manifold of the pump. These same 

hydraulic forces lift the discharge valve ball 

off its seat, while the opposite discharge 

valve ball is forced onto its seat, forcing fluid 

to flow through the pump discharge. The 

movement of diaphragm A toward the 

center of the pump creates a vacuum within 

liquid chamber A. Atmospheric pressure 

forces fluid into the inlet manifold of the 

pump. The inlet valve ball is forced off its 

seat allowing the fluid being pumped to fill 

the liquid chamber.

 

FIGURE 3 

At completion of the stroke, the 

air valve again redirects air to the back 

side of diaphragm A, which starts 

diaphragm B on its exhaust stroke. As the 

pump reaches its original starting point, 

each diaphragm has gone through one 

exhaust and one discharge stroke. This 

constitutes one complete pumping cycle. 

The pump may take several cycles to 

completely prime depending on the 

conditions of the application.

 

HOW IT WORKS — AIR DISTRIBUTION SYSTEM

 

 

The heart of the patented Pro-Flo

®

  SHIFT Air Distribution 

System (ADS) is the air valve assembly. The air valve design 

incorporates an unbalanced spool with the small end of the 

spool being pressurized continuously while the large end of the 

spool is alternately pressurized, then exhausted to move the 

spool. The air valve spool directs pressurized air to one 

chamber while exhausting the other. The air forces the main 

shaft/diaphragm assembly to move to one side – discharging 

liquid on that side and pulling liquid in on the other side. When 

the shaft reaches the end of the stroke, the inner piston 

actuates the pilot spool, which controls the air to the large end 

of the air valve spool. The repositioning of the air valve spool 

routes the air to the other air chamber.

 

  Section 3 

HOW IT WORKS  — PUMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание WILDEN SANIFLO PS15 Hygienic Series

Страница 1: ...EOM ENGINEERING OPERATION MAINTENANCE PS15 Saniflo Hygienic Series Clamped Metal Pumps WIL 12630 E 04 Where InnovationFlows...

Страница 2: ...ragm Fitted 11 Suction Lift Curves 12 Section 6 Suggested Installation Operation 13 Maintenance and Troubleshooting Section 7 Disassembly Reassembly 16 Pump Disassembly 16 Wil Gard Diaphragm Sensor 19...

Страница 3: ...ifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are regist...

Страница 4: ...pply pressure CAUTION The process fluid and cleaning fluids must be chemically compatible with all wetted pump components Consult the Chemical Resistance Guide CAUTION Do not exceed 82 C 180 F air inl...

Страница 5: ...ON OUTER PISTON WETTED PATHS Section 2 WI L D E N P U M P D E S I G N A T I O N S Y S T E M SPECIALTY CODES 0770 Saniflo HS 0770E Saniflo HS 1935 2004 EC 0771 Saniflo HS w Swivel Stand 0771E Saniflo H...

Страница 6: ...ped in the liquid chamber and manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid...

Страница 7: ...4 F 73 2 9 G 683 26 9 H 386 15 2 J 380 15 0 K 586 23 1 L 580 22 9 M 46 1 8 N 400 15 8 P 349 13 8 R 318 12 5 S 356 14 0 T 10 0 4 LW0264 REV B DIMENSIONS ITEM METRIC mm STANDARD inch A 598 23 5 B 175 6...

Страница 8: ...29 48 4 F 73 2 9 G 710 28 0 H 522 20 5 J 514 20 3 K 721 28 4 L 715 28 2 M 46 1 8 N 400 15 8 P 349 13 8 R 394 15 5 S 432 17 0 T 10 0 4 LW0265 REV B DIMENSIONS ITEM METRIC mm STANDARD inch A 598 23 5 B...

Страница 9: ...1 B 204 8 0 C 435 17 1 D 584 23 0 E 598 23 5 F 411 16 2 G 50 2 0 H 411 16 2 J 886 34 9 K 612 24 1 L 606 23 9 M 812 32 0 N 806 31 8 P 397 15 6 R 423 16 7 S 400 15 8 T 349 13 8 U 318 12 5 V 356 14 0 W...

Страница 10: ...hould be specified so that daily operation parameters will fall in the center of the pump s performance curve PS15 SANIFLO HS EZ INSTALL TPE FITTED ShipWeight 98 kg 216 lb Air Inlet 19 mm 3 4 Inlet 76...

Страница 11: ...ld be specified so that daily operation parameters will fall in the center of the pump s performance curve PS15 SANIFLO HS FULL STROKE INTEGRAL PISTON DIAPHRAGM FITTED ShipWeight 98 kg 216 lb Air Inle...

Страница 12: ...4 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 0 bar 30 psig head pressure Example To pump 333 lpm 88 gpm against a discharge head of 4 2 bar 60 psig requ...

Страница 13: ...g at 305 m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosi...

Страница 14: ...r between the valve and the pump to bleed off which improves pump performance You can estimate pumping volume by counting the number of strokes per minute and then multiplying that figure by the displ...

Страница 15: ...ftheair supplytothepump Anair regulator isusedto regulate air pressure A needle valve is used to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partiall...

Страница 16: ...7 Check for any broken inner piston that would cause the air valve spool to be unable to shift Pump runs but little or no product flows 1 Check for pumpcavitation Slowpumpspeeddownto allow thick mate...

Страница 17: ...discharge and air lines Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container Be aware of any hazardous effects of contact with your process fluid NOTE The...

Страница 18: ...emove the inlet manifold clamp bands Step 7 Next remove the clamp bands that secure the ball valve housing to the liquid chamber Step 8 Next remove the ball valve housing valve ball and gasket from li...

Страница 19: ...in the opposite direction loosen and remove one of the two outer pistons Step 11B If your pump is fitted with an IPD the procedure for removing the diaphragm is slightly different In this case simply...

Страница 20: ...primary diaphragm and the back up diaphragm on both sides of the pump at the six o clock position They should be positioned approximately half the distance to the shaft from the edge of the diaphragm...

Страница 21: ...ommended that the pump be disassembled while attached to the stand If it is necessary to remove the pump from the stand while fully assembled use a hoist or mechanical means to support the pump as it...

Страница 22: ...ts of contact with your process fluid The Wilden Pro Flo SHIFT metal pumps utilize a revolutionary Pro Flo SHIFT air distribution system Proprietary composite seals reduce the coefficient of friction...

Страница 23: ...t for nicks wear or damage Replace the pilot spool assembly or sleeve O rings if necessary During reassembly never insert the dimpled end of the pilot spool first this will damage the single urethane...

Страница 24: ...ng pick remove the two 2 Glyd rings from modulator spool bore Inspect and replace if necessary Step 12 Using an appropriate sized wrench remove the pilot exhaust muffler Inspect for damage or contamin...

Страница 25: ...alve Step 16 Remove the air valve spool from the air valve body by threading one air valve bolt into the end of the air valve spool and gently sliding the spool out of the air valve body Inspect seals...

Страница 26: ...P bearing grease or equivalent Clean the inside of the center section shaft bore to ensure no damage is done to new shaft seals A small amount of NLGI grade 2 white EP bearing grease can be applied to...

Страница 27: ...easier 5 With the seal clamped in the pliers insert the seal into the bushing bore and position the bottom of the seal into the correct groove Once the bottom of the seal is seated in the groove relea...

Страница 28: ...ning fluid apply Suggested flow rate for the PS15 HS pump is 100 gpm 22 7 m3 hr usually higher is better Typical CIP temperature is 77 C to 82 C 170 F to 180 F Typical chemicals include NaOH sodium hy...

Страница 29: ...WIL 12630 E 04 Wilden 29 EXPLODED VIEW AND PARTS LISTING PS15 SANIFLO HS EXPLODED VIEW Section 9...

Страница 30: ...ng 1 04 6345 08 23 Plug 1 4 SHCS 3 A 6 02 7825 17 02 7825 17 Wetted Path Components 24 Chamber Liquid CIP 3 EHEDG 2 15 5000 10 385P 25 Clamp Band Assy 4 8 15 7202 03 26 Elbow 3 EHEDG 4 15 5240 10 385P...

Страница 31: ...V Assy 4 1 15 7654 03 15 7654 03 49 Nut Cap 5 16 18 Pump Stand 4 08 6600 03 72 50 Pad Pump Stand 4 08 7670 20 08 7670 20 51 Washer Flat 406 X 812 X 065 2 04 6740 03 04 6740 03 52 Screw HHC 3 8 16 X 1...

Страница 32: ...WIL 12630 E 04 Wilden 32 PS15 SANIFLO HS 1935 2004 EC EXPLODED VIEW EXPLODED VIEW AND PARTS LISTING...

Страница 33: ...17 02 7825 17 Wetted Path Components 24 Chamber Liquid CIP 3 EHEDG 2 15 5000 10 385P 25 Clamp Band Assy 4 8 15 7202 03 26 Elbow 3 EHEDG 4 15 5240 10 385P 27 T Section 3 EHEDG 2 15 5160 10 385P T Sect...

Страница 34: ...ssy 4 1 15 7654 03 15 7654 03 49 Nut Cap 5 16 18 Pump Stand 4 08 6600 03 72 50 Pad Pump Stand 4 08 7670 20 08 7670 20 51 Washer Flat 406 X 812 X 065 2 04 6740 03 04 6740 03 52 Screw HHC 3 8 16 X 1 1 4...

Страница 35: ...WIL 12630 E 04 Wilden 35 PS15 SANIFLO HS Horizontally Mounted EXPLODED VIEW EXPLODED VIEW AND PARTS LISTING...

Страница 36: ...iquid CIP 3 EHEDG 2 15 5000 10 385P 24 Clamp Band Assy 4 10 15 7202 03 25 Reducer 4 3 4 15 5290 10 83P 26 Clamp Band Assy Large 3 2 08 7300 03 385 27 Screw HHC 3 8 16 X 3 1 4 4 08 6120 03 28 Washer Fl...

Страница 37: ...WIL 12630 E 04 Wilden 37 PS15 SANIFLO HS Horizontally Mounted 1935 2004 EC EXPLODED VIEW EXPLODED VIEW AND PARTS LISTING...

Страница 38: ...00 10 385P 24 Clamp Band Assy 4 10 15 7202 03 25 Reducer 4 3 4 15 5290 10 83P 26 Clamp Band Assy Large 3 2 08 7300 03 385 27 Screw HHC 3 8 16 X 3 1 4 4 08 6120 03 28 Washer Flat 406 X 875 X 125 4 04 6...

Страница 39: ...5 FDA Wil Flex 08 1065 57 08 1022 57 08 1031 57 15 1086 57 FDA FKM 15 1375 68 15 1215 68 Product Contact Components LW0271 Rev G PS15 SANIFLOTM HS 1935 2004 EC Material Diaphragms Color Code Full Stro...