background image

 

WIL-10187-E-03

 

Wilden

®

 

Precautions - Read First!

 

 
 

CAUTION: 

Do not apply compressed air to the exhaust port 

 pump will not function. 

 

CAUTION: 

Do not over lubricate air supply 

 excess 

lubrication will reduce pump performance. 

 

TEMPERATURE LIMITS*:

 

 

Acetal 

29°C to 82°C   

20°F to 180°F 

Buna-N 

12°C to 82°C   

10°F to 180°F 

Geolast

®

 

40°C to 82°C   

40°F to 180°F 

Neoprene 

18°C to 93°C   

0°F to 200°F 

Nordel

®

 EPDM 

51°C to 138°C  

60°F to 280°F 

Nylon 

18°C to 93°C       0°F to 200°F 

PFA 

7°C to 107°C  

45°F to 225°F 

Polypropylene 

0°C to 79°C  

32°F to 175°F 

Polyurethane 

12°C to 66°C     10°F to 150°F 

PVDF 

12°C to 107°C  

10°F to 225°F 

Saniflex™

 

29°C to 104°C  

20°F to 220°F  

SIPD PTFE with EPDM-
backed 

4°C to 137°C  

40°F to 280°F  

SIPD PTFE with Neoprene-
backed 

4°C to 93°C  

40°F to 200°F  

PTFE

1

 

4°C to 104°C 

40°F to 220°F 

FKM 

40°C to 177°C  

40°F to 350°F 

Wil-

Flex™

 

40°C to 107°C  

40°F to 225°F 

1

4°C to 149°C (40°F to 300°F) - 13 mm (1/2") and 25 mm (1")  

models only. 

NOTE: 

Not all materials are available for all models. Refer to Section 2 for 

material options for your pump. 

 

CAUTION: 

When choosing pump materials, be sure to 

check the temperature limits for all wetted components. 

Example: FKM has a maximum limit of 177°C (350°F) but 

polypropylene has a maximum limit of only 79°C (175°F). 

 

CAUTION: 

Maximum temperature limits are based upon 

mechanical stress only. Certain chemicals will significantly 

reduce maximum safe operating temperatures. Consult 

engineering guide for chemical compatibility and temperature 

limits. 

 

CAUTION: 

Always wear safety glasses when operating 

pump. If diaphragm rupture occurs, material being pumped 

may be forced out air exhaust. 

Plastic series pumps are made of virgin plastic and are not 

UV-stabilized. Direct sunlight for prolonged periods can cause 

deterioration of plastics. 

 

WARNING: 

Prevent static sparking 

 If static 

sparking occurs, fire or explosion could result. Pump, 
valves, and containers must be grounded when 

handling flammable fluids and whenever discharge of 
static electricity is a hazard. To ground the Wilden 

“Champ”

, all clamp bands must be grounded to a 

proper grounding point 

 

CAUTION: 

Do not exceed 8 .6 bar (125 psig)  

air supply pressure. 

 

CAUTION: 

Before any maintenance or repair is 

attempted, the compressed air line to the pump 

should be disconnected and all air pressure allowed 

to bleed from pump. Disconnect all intake, 

discharge and air lines. Drain the pump by turning it 

upside down and allowing any fluid to flow into a 

suitable container

 

CAUTION: 

Blow out air line for 10 to 20 seconds 

before attaching to pump to make sure all pipeline 

debris is clear. Use an in-line air filter.  

A 5µ (micron) air filter is recommended. 

 

NOTE: 

When installing PTFE diaphragms, it is 

important to tighten outer pistons simultaneously 

(turning in opposite directions) to ensure tight fit. 

 

NOTE: 

P8 PVDF and PFA pumps come standard 

from the factory with expanded PTFE gaskets 

installed in the diaphragm bead of the liquid 

chamber, in the T-section and in the ball and seat 

area. PTFE gaskets cannot be re-used. 

 

NOTE: 

Before starting disassembly, mark a line from 

each liquid chamber to its corresponding air 

chamber. This line will assist in proper alignment 

during reassembly. 

 

CAUTION: 

The P8 plastic pump is not submersible. 

 

 

CAUTION: 

Pumps should be flushed thoroughly with 

water before installation into process line. 

 

 

CAUTION: 

Tighten all hardware prior to installation. 

 

 

 

 

 

Section 1 

Содержание WILDEN PRO-FLO P8

Страница 1: ...EOM ENGINEERING OPERATION MAINTENANCE P8 Clamped Plastic Pump WIL 10187 E 03 Where InnovationFlows...

Страница 2: ...troke PTFE Fitted 9 P8 Plastic Full Stroke PTFE Fitted 9 P8 Plastic Ultra FlexTM Fitted 9 Suction Lift Curves 10 Section 6 Suggested Installation Operation 11 Maintenance and Troubleshooting Section 7...

Страница 3: ...ifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are regist...

Страница 4: ...y be forced out air exhaust Plastic series pumps are made of virgin plastic and are not UV stabilized Direct sunlight for prolonged periods can cause deterioration of plastics WARNING Prevent static s...

Страница 5: ...POLYPROPYLENE VALVE SEAT O RING BN BUNA N Red Dot PU POLYURETHANE Brown TV PTFE ENCAP FKM WF WIL FLEX Santoprene NOTE Most Elastomeric materials use colored dots for identification NOTE Not all models...

Страница 6: ...hamber and mani fold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through th...

Страница 7: ...STANDARD inch A 490 19 3 B 76 3 0 C 414 16 3 D 693 27 3 E 770 30 3 F 89 3 5 G 417 16 4 H 333 13 1 J 381 15 0 K 307 12 1 L 227 8 9 M 254 10 0 N 15 0 6 METRIC mm STANDARD inch P 122 DIA 4 8 DIA R 152 D...

Страница 8: ...mps should be specified so that daily operation parameters will fall in the center of the pump s performance curve P8 PLASTIC TPE FITTED Ship Weight Polypropylene 34 kg 75 lb PVDF 43 kg 95 lb Air Inle...

Страница 9: ...d performance pumps should be specified so that daily operation parameters will fall in the center of the pump s performance curve P8 PLASTIC FULL STROKE PTFE FITTED Ship Weight Polypropylene 34 kg 75...

Страница 10: ...was calculated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure Example To pump 257 lpm 68 gpm against a discharge pressure head of 2 0 bar 30 psig requires 4 1 bar 60 psig...

Страница 11: ...g at 305 m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosi...

Страница 12: ...eration When operation is controlled by a solenoid valve in the air line three way valves should be used This valve allows trapped air between the valve and the pump to bleed off which improves pump p...

Страница 13: ...he volume and or pressure of the air supply to the pump An air regulator is used to regulate air pressure A needle valve is used to regulate volume Pump discharge rate can also be controlled by thrott...

Страница 14: ...l to be unable toshift 7 Remove plug from pilot spoolexhaust Pump runs but little or no product flows 1 Check for pump cavitation slow pump speed down to allow thick material to flow into liquid chamb...

Страница 15: ...tribution system is based on a revolutionary design which increases reliability and performance The model P8 are available in injection molded polypropylene PLEASE read all directions before starting...

Страница 16: ...able performance Step 5 Remove the two small clamp bands which fasten the intake manifold to the liquid chambers Step 6 Lift intake manifold from liquid chambers and center section to expose intake va...

Страница 17: ...uter piston diaphragm and inner piston remain attached to the shaft and the entire assembly can be removed from the center section Figure 12 2 The outer piston diaphragm and inner piston separate from...

Страница 18: ...istribution system A 13 mm 1 2 air inlet connects the air supply to the center section Proprietary composite seals reduce the coefficient of friction and allow the P4 to run lube free The Pro Flo air...

Страница 19: ...from center block Step 9 With O ring pick gently remove the o ring from the opposite side of the center hole cut on the spool Gently remove the pilot spool from sleeve and inspect for nicks or gouges...

Страница 20: ...Large Clamp Band Rubber Fitted 18 6 N m 165 in lb Large Clamp Band PTFE Fitted 18 6 N m 165 in lb Air Chamber Screws HSFHS 3 8 16 47 5 N m 35 ft lb Figure A INSTALLATION The following tools can be use...

Страница 21: ...g surfaces must be properly aligned in order to ensure positive sealing characteristics Step 1 Gently remove the adhesive covering from the back of the PTFE tape Ensure that the adhesive strip remains...

Страница 22: ...WIL 10187 E 03 Wilden 22 Exploded View and Parts Listing P8 PLASTIC FULL STROKE DIAPHRAGM FITTED EXPLODED VIEW Section 8...

Страница 23: ...n 2 08 3700 01 08 3700 01 21 Diaphragm 2 22 Outer Piston 2 08 4550 21 500 08 4550 21 500 23 Manifold Tee Section 2 08 5160 20 08 5160 20 24 Small Clamp Band Assy 4 08 7100 03 500 08 7100 05 500 25 Sma...

Страница 24: ...WIL 10187 E 03 Wilden 24 Exploded View and Parts Listing P8 PLASTIC REDUCED STROKE DIAPHRAGM FITTED EXPLODED VIEW...

Страница 25: ...Ring 2 04 3890 03 04 3890 03 20 Inner Piston 2 08 3750 01 08 3750 01 Inner Piston Ultra Flex 2 08 3761 01 08 3761 01 21 Diaphragm Back up 2 22 Diaphragm 2 23 Outer Piston 2 08 4600 21 500 08 4600 21...

Страница 26: ...N A N A EPDM 08 1010 54 08 1020 54 N A N A 08 1080 54 N A N A FKM 08 1010 53 08 1020 53 N A N A 08 1080 53 N A N A Saniflex 08 1010 56 N A N A N A 08 1080 56 08 1060 56 08 1065 56 PTFE 08 1010 55 N A...

Страница 27: ...WIL 10187 E 03 Wilden Notes...

Страница 28: ...Terrace CA 92313 5651 USA P 1 909 422 1730 F 1 909 783 3440 psgdover com Where Innovation Flows PSG reserves the right to modifythe information and illustrations contained in this document without pr...

Отзывы: