20
QuickScan 6000/6000 Plus Programming Guide
Software Control
X
ON
/X
OFF
— this is software handshaking that allows the host to
control data transmission. If the host sends an X
OFF
command to
the scanner, the scanner will not send the bar code data until it
receives an X
ON
command from the host. If the host sends the
X
OFF
command during data transmission, the host will receive
additional characters for no more than 2msec
1
.
NOTE
Hardware/software controls are mutually exclusive. Enable only one
of these features at a time, as enabling multiple controls can produce
unpredictable results.
SET
----------------------------------------------
D
ISABLE
H
ARDWARE
C
ONTROL
-----
E
NABLE
CTS/RTS F
LOW
C
ONTROL
--
E
NABLE
CTS S
CAN
C
ONTROL
----
E
NABLE
X
ON
/ X
OFF
----------------
D
ISABLE
X
ON
/X
OFF
----------------
END
----------------------------------------------
1
Varies slightly depending upon baud rate selected.
H
ARDWARE
C
ONTROL
S
OFTWRE
C
ONTROL