background image

RS-232 Features

Product Reference Guide

5-75

RS-232 TTL Invert

Enables/disables inversion of TTL.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code below which represents the desired setting for this 

feature. You’ll need to cover any unused bar codes on this and the 
facing page to ensure that the scanner reads only the bar code you 
intend to scan.

3. Complete the programming sequence by scanning the SWITCH 

bar code.

RS-232 TTL INVERT = DISABLE

RS-232 TTL INVERT = ENABLE

Содержание Magellan 2200VS omega

Страница 1: ...Magellan 2200VS and 2300HS Product Reference Guide ...

Страница 2: ...0 5198649 5200597 5202784 5208449 5210397 5212371 5212372 5214270 5229590 5231293 5232185 5233169 5235168 5237161 5237162 5239165 5247161 5256864 5258604 5258699 5260554 5274219 5296689 5298728 5311000 5327451 5329103 5330370 5347113 5347121 5371361 5382783 5386105 5389917 5410108 5420410 5422472 5426507 5438187 5440110 5440111 5446271 5446749 5448050 5463211 5475206 5475207 5479011 5481098 549132...

Страница 3: ...ite Preparation and Installation 2 1 Unpacking 2 1 Operational Verification 2 2 Installation Model 2200VS 2 3 Installation Model 2300HS 2 6 Chapter 3 Operation and Maintenance 3 1 Scanning Items Model 2200VS 3 2 Scanning Items Model 2300HS 3 3 Operational Controls 3 4 Operational Modes 3 4 Power Up Selftest Pre Operation 3 4 Operating Mode 3 5 Additional Functions 3 7 Programming 3 7 Scanner Diagn...

Страница 4: ...18 Scanner Button Options 5 19 Power up Beep Control 5 21 Good Read Beep Control 5 23 Good Read Beep Frequency 5 24 Good Read Beep Length 5 26 Good Read Beep Volume 5 27 Good Read When to Indicate 5 30 EAS Active State 5 32 EAS Timeout 5 33 Aux Port Mode 5 34 Productivity Index Reporting PIR 5 36 Interface Related Features 5 37 Interface Type 5 37 Maximum Host Transmitted Message Length 5 51 Numbe...

Страница 5: ... 232 Use ETX 5 97 Set Single Cable RS 232 ETX Character 5 98 PC Keyboard Wedge and USB Keyboard Interfaces 5 99 Connect to a Laptop No Keyboard Attached 5 100 Send Control Function Characters continued 5 102 Caps Lock continued 5 104 Country Mode continued 5 106 Country Mode continued 5 107 Country Mode continued 5 108 Country Mode continued 5 109 Country Mode continued 5 110 Country Mode continue...

Страница 6: ...144 EAN 13 128 Supplemental Label ID 5 145 Bookland AIM ID 5 146 Bookland Label ID 5 147 EAN 8 Enable 5 148 EAN 8 Check Character Transmission 5 149 Expand EAN 8 to EAN 13 5 150 EAN 8 Label ID 5 151 EAN 8 2 Digit Supplemental Label ID 5 152 EAN 8 5 Digit Supplemental Label ID 5 153 EAN 8 128 Supplemental Label ID 5 154 EAN 8 Decoding Levels 5 155 Other UPC EAN Options 5 158 UPC EAN Reconstruction ...

Страница 7: ...Fixed Length 1 5 200 Code 39 Fixed Length 2 5 201 Code 39 Stitching 5 202 Pharmacode 39 Enable 5 203 Pharmacode 39 Start Stop Character Transmission 5 204 Pharmacode 39 Check Character Transmission 5 205 Pharmacode 39 Label ID 5 206 Code 128 Enable 5 207 Code 128 Transmit Function Characters 5 208 Convert Code 128 to Code 39 5 209 Code 128 AIM ID 5 210 Code 128 Label ID 5 211 Code 128 Length Contr...

Страница 8: ...trol 5 250 Code 93 Maximum Label Length 5 251 Code 93 Minimum Label Length 5 252 Code 93 Fixed Length 1 5 253 Code 93 Fixed Length 2 5 254 Code 93 Stitching 5 255 MSI Plessey Enable 5 256 MSI Plessey Check Character Calculation 5 257 MSI Plessey Number of Check Characters 5 258 MSI Plessey Check Character Transmission 5 259 MSI Plessey AIM ID 5 260 MSI Plessey Label ID 5 261 MSI Plessey Length Con...

Страница 9: ...eeper Indications Controls A 1 Volume Tone Push Button A 2 Green LED Indicator A 3 Appendix B Cable Information B 1 Appendix C Keypad C 1 Appendix D Host Commands D 1 Appendix E Factory Defaults E 1 Appendix F Handheld Data Format Requirements F 1 Handheld Data Format Requirements General F 1 PSC Handheld Data Format Requirements F 2 AIM Formats F 10 ...

Страница 10: ...viii Magellan 2200VS and 2300HS ...

Страница 11: ...d testing are also explained in this section Chapter 3 Operation and Maintenance describes use and maintenance providing details about operator controls programming and diagnostic modes Scanner routine maintenance is outlined in this section as well Chapter 4 Problem Isolation provides an outline of three scanner test modes Selftest Operational Tests and Diagnostic Tests Descriptions of the error ...

Страница 12: ... Factory Defaults is a listing of standard factory defaults for the various programmable features Appendix F Handheld Data Format Requirements provides application notes to describe the general format of data that can be accepted by the scanner through the auxiliary port as transmitted from a handheld scan ner How to Use This Manual You ll find it helpful to familiarize yourself with the first sec...

Страница 13: ...anual CAUTION blocks inform you that proper handling adherence to the procedures described is required to avoid damage to equipment and or property WARNING blocks alert you to potential physical harm or injury These statements do not include potentially fatal hazards which would be designated as DANGER blocks Use of this product does not warrant the need for a DANGER block Speaker Scan Window Uppe...

Страница 14: ... AUXILIARY PORT POWER Connection to this port is Optional DC Brick Input Label Data Application Download where appropriate Test Port On Screen Programming OSP Application Download RS 232 Handheld Scanner Input Auxiliary RS 232 Label Data Output EAS interlock EAS Connection Connection to this port is Optional Electronic Article Surveillance Connection Power EAS Opening Aux Port Scanner Host Pow er ...

Страница 15: ...essories Scanning The scanner has a scan zone immediately in front of or above the scan window where the scanner projects laser light in order to scan items Scan lines form a zone where bar code labels are read Refer to the Operation and Maintenance section of this manual for more details about the topic Scanning Items Model 2200VS AC Adapter Figure 1 3 is an illustration of the AC DC Adapter part...

Страница 16: ...pment that is it must be free of excess electrical noise If the adapter will not plug into your AC power receptacle the model shipped is not compatible with your electrical system Please contact your distributor immediately to receive the necessary information and compo nents to ensure electrical compatibility Operation Storage 40 C 104 F 10 C 50 F Temperature 10 to 40 C 50 to 104 F Dust Resistant...

Страница 17: ...SAA 4004 0707 100V MITI 4004 0708 230V EURO 4004 0709 120V Desktop US 4004 0710 CAUTION Safe operation of your scanner or scanner requires properly grounded elec trical outlets Be sure to have a qualified electrician certify the earth ground connection on circuits which will be used to power the unit NOTE The scanner is powered on off by connecting disconnecting its AC power supply ...

Страница 18: ...of the scanner Laser Light Viewing The scan window is the only aperture through which laser light may be observed in this product Exposure to the light emitted from the scan window s has been shown not to be harmful The safety record of bar code scanning is perfect after millions of hours of use worldwide This safe and efficient use of laser technology has gained wide acceptance in industries thro...

Страница 19: ...mitted the failing unit should be disconnected from its power supply until repaired by a qualified technician WARNING This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment Th...

Страница 20: ...ES WITH 21CFR 1040 AS APPLICABLE AS A CLASS IIA PRODUCT This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la Classe A est confirme à la norme NMB 003 du Canada N263 NRTL Sa fe ty te st ed Pr od uc tio n mo nit or ed PRODUCT SERVICE Product of USA U S PSC Inc 959 Terry Street Eugene OR 97402 USA XXXXXXXXXXXX CAUTION CLASS 3R LASER RADIATION WHEN OPEN AVOID DIR...

Страница 21: ...This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la Classe A est confirme à la norme NMB 003 du Canada N263 NRTL Sa fe ty te st ed Pr od uc tio n mo nit or ed PRODUCT SERVICE Product of USA U S PSC Inc 959 Terry Street Eugene OR 97402 USA XXXXXXXXXXXX CAUTION CLASS 3R LASER RADIATION WHEN OPEN AVOID DIRECT EYE EXPOSURE 6 1012 COVERED BY ONE OR MORE OF THE FO...

Страница 22: ...ctrical United States UL 1950 TÜV NRTL Canada CAN CSA C22 2 No 1950 TÜV NRTL World IEC60950 IEC 825 1 2001 TÜV CB Emmisions United States 47CFR Part 15J FCC Canada ICES 0003 Class B Europe EN 55022 Class B Australia N Zealand AS NZ 3548 Class B Japan VCCI Class B Taiwan CNS 13438 Class B Safety Emissions EMC Directive 89 336 EEC CE Mark LV Directive 73 23 EEC CE Mark Laser Safety United States CDR...

Страница 23: ...Supplementals and Add ons 2 5 digit supplementals and Code 128 Reduced Space Symbology RSS RSS 14 and RSS expanded both support stacked component EAN 8 13 JAN 8 13 EAN JAN two label UCC EAN 128 Code 39 Code 39 full ASCII Code 128 including conversion to Code 39 Code 93 Interleaved 2 of 5 I 2 of 5 Italian Pharmacode Code 39 Codabar Standard 2 of 5 MSI Plessey ...

Страница 24: ...Introduction 1 14 Magellan 2200VS and 2300HS NOTES ...

Страница 25: ...f damage is found report it to your carrier immedi ately Lift any accessories from the box including the AC DC Power Sup ply and the Quick Reference Guide Familiarize yourself with the Quick Reference Guide Leave the guide at the checkstand when the installation is complete Remove the protective packing and carefully lift the scanner from the carton Be sure to save the box and all packing material...

Страница 26: ...er into the scanner see Figure 2 1 Figure 2 1 Scanner Connections 3 Plug the AC Adapter into an AC power outlet POSTERMINAL AUXILIARY PORT POWER Connection to this port is Optional DC Brick Input Label Data Application Download where appropriate Test Port On Screen Programming OSP Application Download RS 232 Handheld Scanner Input Auxiliary RS 232 Label Data Output EAS interlock EAS Connection Con...

Страница 27: ...ow 1 Determine the best location for scanner installation Some consider ations are Cable routing to and from the scanner Can cables and connected devices be routed in such a way as to be protected from damage or tampering Depending on your installation it may be necessary to drill a 1 1 4 3 2cm hole in the countertop or wall Mounting stability Avoid placing the scanner in such a way as to subject ...

Страница 28: ...4 Remove the Connector Cover and connect the cables to the scanner Reference Figure 2 2a and Figure 2 1 5 Route the cables as shown in Figure 2 2b or Figure 2 2c 6 Switch the terminal OFF 7 Connect the interface cable to the terminal 8 Connect the AC Adapter to the AC outlet 9 Switch the terminal ON 10 Verify operation by scanning a few known good bar code labels The scanner should now be communic...

Страница 29: ...stallation Model 2200VS Product Reference Guide 2 5 Figure 2 2 Magellan 2200VS Installation a b c d Connector Cover Route cables for countertop mount Route cables for wall mount To Countertop T o W a l l ...

Страница 30: ...t to excess vibration bumping spillage etc Peripheral connections from the scanner such as a handheld device 2 The countertop must be modified to accept the scanner At the time of this writing three options are available Figure 2 3a shows the dimensions for the opening and other details if a shelf is to be built to support the unit Figure 2 3b details the cutout dimensions if an adapter fixture ho...

Страница 31: ... installation b Adapter w flange above counter c Adapter w flange recessed to be flush with counter 6 26 159mm 3 47 88 1mm Rim rests on top of counter 6 26 159mm Rim is flush with counter Cut hole 6 26 159mm 3 52 89 4mm 6 26 159mm 7 91 201mm Routing is 0 050 1 27mm deep Radius 0 21 5 3mm x4 Cut hole Rim of adapter Cut hole Routed ledge for rim 7 40 188mm ...

Страница 32: ...tions 9 Verify operation by scanning a few known good bar code labels The scanner should now be communicating the bar code data to the POS terminal This completes the installation instructions for this model Connector Cover NOTE Reference Chapter 4 Problem Isolation if the scanner does not perform as expected ...

Страница 33: ...rence Guide 3 1 Chapter 3 Operation and Maintenance The information contained in this section describes how to operate and maintain the scanner Topics include scanning tips and scan window cleaning and replacement ...

Страница 34: ...here it is necessary to minimize the need to grip or lift items moving the bar code directly toward the scan window to be read see Figure 1b This Presentation technique is most often used in low throughput variety convenience market and pharmacy applications where usable countertop space is at a premium and Sweep scan ning is not possible Figure 1 Sweep and Presentation Scanning Technique Scanner ...

Страница 35: ...or pick them up Bar codes are effortlessly scanned when swept through the zone projected from the substantial scan window as shown in Figure 1a Figure 3 1 Operating the Scanner NOTE Facing bar code labels in the direction of scanning or toward the scan window will optimize the scan rate The arrow on the scanner s top cover indicates the direction scanned items should be moved see Figure 1b Scanner...

Страница 36: ... Pre Operation Pre Operation describes those steps that must be successfully completed before the scanner sounds the initial good read tone and illuminates the LED lamp indicating readiness for operation These steps include Power Up Selftest Error Reporting and Operational Configuration Power Up Selftest Power Up Selftest begins when power is applied The scanner s software immediately begins the t...

Страница 37: ...a tone is emitted if configured to do so and the unit enters an operational configuration state The scanner will automatically load your specific interface settings which are required to communicate with the host system No bar code label can be in the scan volume while the unit is in this state Progress is halted until the label has been removed thereby ensuring that no extraneous bar code data is...

Страница 38: ... left idle for a preset period of time the laser and or motor automatically turns off goes to sleep This state is called Sleep Mode and is indicated by a slow blink of the green light blinking at a 2 second rate To wake up the unit press the Volume Tone Push Button wave your hand in front of the scan window or scan an item using an attached auxiliary scanner if present The scanner will recognize t...

Страница 39: ...ms Under normal operation the scanner stores label data awaiting the signal which transmits it to the host When the scanner is not connected to a host it may read and store only up to two labels then quit reading until power is cycled clearing the memory This mode of operation removes this limitation To place the scanner in Scanner Diagnostic Mode press the Volume Tone Push Button for approximatel...

Страница 40: ... sounded by a rapid number of beeps If the motor had been spinning the lamps will blink while the motor spins down At that point the motor will spin back up and the scanner will continue to run the Selftest diagnostics For more informa tion see the topic Power Up Selftest Pre Operation earlier in this chapter Operational Maintenance The scanner will provide dependable service for many years The fo...

Страница 41: ...e scanner indicates readiness for operation This pre operational period is the time between power up and normal operation during which the motor comes up to speed and software firm ware and hardware are being tested These tests ensure that all subsystems are fully functional before turning on the Visible Laser Diode VLD Refer to Chapter 3 Operational Modes for a more detailed description of this a...

Страница 42: ... problems are caused by either the scanner POS terminal or communication links between them trou bleshooting flowcharts provided in this chapter focus on these compo nents Additionally the AC DC Power Supply and scanner cables are potential problems addressed The flowcharts provided here walk you through a diagnostic process that will isolate the failed component and instruct as to the corrective ...

Страница 43: ... what these codes mean and what action should be taken for each When troubleshooting always remember to check all cable connections first before proceeding with other problem isolation steps Error Code Probable Cause Corrective Action 0 Blinking Configuration No POS interface has been selected Null interface See Chapter 5 Interface Type to select the required interface using programming bar codes ...

Страница 44: ...west value for approx 3 seconds LED flashes on and off Consult the Selftest flowchart if you re unsure the unit has passed Selftest Flashing Green LED If the Green LED is flashing slowly the scanner is most likely in Sleep Mode Press and release the Volume Tone Push Button or wave your hand in front of the vertical window to wake up the scanner A flashing Green LED can also mean the scanner has be...

Страница 45: ... error code 2 thru A Unit passes Selftest YES NO Is the LED blinking in error YES YES NO NO Is the error code 1 Is the error code 1 SELFTEST START No interface selected Null Interface Select an interface Scan the Factory Defaults bar code in Section 6 to enable the default configuration file Restart the unit ...

Страница 46: ...the data to the POS YES NO Does the scanner read satisfactorily YES NO Does the scanner read satisfactorily Enter Scanner Diagnostic Mode by holding the Volume Tone Push Button for 4 seconds until first 3 and then 6 rapid tones are sounded then release Scan a known good bar code A good read is signified by one flash of the LED and a single beep1 If unexpected data is being sent from the host to th...

Страница 47: ...ers using the information and programming bar codes provided in Section 5 Check interface and I F options inactive symbologies and other configurable features Troubleshoot the host or call Tech Support YES NO Does the scanner read satisfactorily Check the interface I F cable connections If possible retest the system using a known good I F cable YES NO Does the scanner pass the data to the POS ...

Страница 48: ...Problem Isolation 4 8 Magellan 2200VS and 2300HS NOTES ...

Страница 49: ...information needed to understand and configure fea tures The following descriptions will help you to determine where to go from here Understanding the Basics If you have little or no prior experience with programming using bar code labels you should review the first few pages of this section to familiarize yourself with the basics of scanner programming before performing any changes to your config...

Страница 50: ...o be placed into operation Customizing Your Scanner s Operation Most scanner programming falls within three general categories General Scanner Features are features common to all interface types Examples include beeper adjustments such as volume and length read verification settings etc Interface Related Features are the mandatory settings necessary to allow communication with your host terminal E...

Страница 51: ... feature settings can be modified to accom modate your system s unique requirements These settings can be commu nicated to the scanner in one of two ways 1 Commands can be sent directly from the host A limited set of host commands are available Refer to Appendix D for more details or contact Tech Support 2 The easiest most comprehensive way to program the scanner is to use the Configurator Express...

Страница 52: ...ature Aux Port Mode must be set to External Handheld Input to allow operation What Is Programming Mode Programming Mode is a state in which the scanner must be placed in order to accept commands via programming bar code labels When pro gramming using the bar code labels in this manual the scanner is typically placed in Programming Mode by scanning the SWITCH label While in the Programming Mode the...

Страница 53: ...e bar code before completing all input will result in an error tone and cause the scanner to exit Programming Mode Under these circumstances the current feature you were trying to set is thrown out any previous bar codes scanned dur ing the session will take effect 1 Some features such as Minimum Label Length require you to select the label s length by scan ning a series of single digit bar codes ...

Страница 54: ...isconnected Disconnecting power during Pro gramming Mode before scanning the SWITCH bar code will cause all new settings to be ignored On power up the scanner will return to previous settings 4 Maintain a good record of all changes made to ensure that you know if the original factory settings have been changed NOTE It is recommended that programming sessions be limited to one feature at a time Sho...

Страница 55: ...d Then a value must be entered before ending the programming session In the example three digits must be scanned from the number pad in Appendix C This type of format requiring several bar codes is nec essary to allow flexible programming for item values with larger numeric ranges C The programming sequence shown in example C requires scanning of a single extended length bar code This special prog...

Страница 56: ...Table 5 1 Programming Sequence 1 1 C A B 2 3 1 2 3 4 5 6 SET SWITCH ENABLE NEW FEATURE ENABLE NEW FEATURE USING THE FOLLOWING SETTINGS SWITCH SWITCH SWITCH 0 8 ITEM TAG ITEM VALUE END RESET 0 ONE BAR CODE CONTAINS SWITCH ITEMTAG ITEMVALUE SWITCH ...

Страница 57: ...bar code to return the scanner to the default settings configured at the factory This bar code is typically used to return the scanner to a known operating state when the present programming status is not known faulty or suspect The process of Returning to Factory Settings requires two steps 1 Scan the Return to Factory Settings bar code 2 Set your required interface type using the instructions in...

Страница 58: ...nt out to the host via the scanner interface This allows the bar code to be scanned continuously without requiring a response from the POS terminal To return the scanner to normal function scan the TEST MODE DIS ABLE bar code below TEST MODE DISABLE TEST MODE ENABLE NOTE DO NOT scan the SWITCH bar code before and after scanning the bar codes on this page Scanning the TEST MODE DISABLE bar code set...

Страница 59: ...he Double Read Timeout 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code DOUBLE READ TIMEOUT 400ms DOUBLE READ TIMEOUT 600ms NOTE If the incidence of multiple reads is ...

Страница 60: ... and 2300HS Double Read Timeout continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan DOUBLE READ TIMEOUT 800ms DOUBLE READ TIMEOUT 1 SECOND ...

Страница 61: ...sing this feature can prolong the life of the VLDs To set the Laser Timeout 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code LASER TIMEOUT 5 MINUTES ...

Страница 62: ...2200VS and 2300HS Laser Timeout continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan LASER TIMEOUT 10 MINUTES LASER TIMEOUT 15 MINUTES ...

Страница 63: ...om the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code MOTOR TIMEOUT 5 MINUTES NOTE Laser safety requires that the laser switch off before the motor If you set the motor timeout shorter than the laser timeout the motor and t...

Страница 64: ...2200VS and 2300HS Motor Timeout continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan MOTOR TIMEOUT 10 MINUTES MOTOR TIMEOUT 15 MINUTES ...

Страница 65: ...t Reference Guide 5 17 Motor Timeout continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan MOTOR TIMEOUT 30 MINUTES MOTOR TIMEOUT 60 MINUTES ...

Страница 66: ...ons are Off On dim To set the LED Idle State 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code GREEN LED IDLE STATE OFF GREEN LED IDLE STATE ON DIM ...

Страница 67: ...set only Disable all button functions To set the desired Scanner Button Option 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code SCANNER BUTTON OPTION ENABLE ALL FUNCTI...

Страница 68: ... Button Options continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan SCANNER BUTTON OPTION ENABLE RESET ONLY SCANNER BUTTON OPTION DISABLE ALL BUTTON FUNCTIONS ...

Страница 69: ... up Choices are No beep One beep Three beeps To set the Power up Beep 1 Scan the SWITCH bar code 2 Scan your selection from the three bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code POWER UP BEEP OFF ...

Страница 70: ...VS and 2300HS Power up Beep Control continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan POWER UP BEEP ONE BEEP POWER UP BEEP THREE BEEPS ...

Страница 71: ...abel To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the two bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code GOOD READ BEEP DISABLE GOOD READ BEEP ENABLE ...

Страница 72: ...660 Hz Medium 866 Hz High 1600 Hz To set the Good Read Beep Frequency 1 Scan the SWITCH bar code 2 Scan your selection from the three bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code GOOD READ BEEP FREQUENCY LOW ...

Страница 73: ...Guide 5 25 Good Read Beep Frequency continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan GOOD READ BEEP FREQUENCY MEDIUM GOOD READ BEEP FREQUENCY HIGH ...

Страница 74: ...the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired good read beep length setting The selectable range is 1 255 which is the timeout in 10 millisecond increments Pad all single and double digit numbers with leading zeroes to yield a three digit entry 001 255 Examples 001 10ms 005 50ms 040 400ms 250 2 500ms 2 5 seconds 4 The scanne...

Страница 75: ... Lowest Volume 1 Medium Low Volume 2 Medium Volume 3 High Volume To set the Good Read Beep Volume 1 Scan the SWITCH bar code 2 Scan your selected volume bar code from this or the following pages You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar co...

Страница 76: ... 2300HS Good Read Beep Volume continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan GOOD READ BEEP VOLUME MEDIUM LOW GOOD READ BEEP VOLUME MEDIUM ...

Страница 77: ... Product Reference Guide 5 29 Good Read Beep Volume continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan GOOD READ BEEP VOLUME HIGH ...

Страница 78: ... Good Read When to Indicate feature 1 Scan the SWITCH bar code 2 Scan the desired mode bar code from this page You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code GOOD READ INDICATE AFTER DECODE NOTE The Indicate after CTS goes inactive mode ap...

Страница 79: ... When to Indicate continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan GOOD READ INDICATE AFTER TRANSMIT GOOD READ INDICATE AFTER CTS GOES INACTIVE THEN ACTIVE RS 232 ONLY ...

Страница 80: ...de allowing the EAS device to deactivate a tag on the product To set the EAS Active State 1 Scan the SWITCH bar code 2 Scan bar code below representing the desired setting You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAS ACTIVE STATE ACT...

Страница 81: ...s only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired EAS Timeout duration The selectable range is 0 255 which is the timeout in 10 millisecond increments Pad all sin gle and double digit numbers with leading zeroes to yield a three digit entry 000 255 Examples 000 EAS timeout disabled 001 10ms 005 50ms 040 400ms 250 2 500ms ...

Страница 82: ...IR Productivity Index Reporting allows the scanner to provide information to an external computer indicating how easy the label was to read To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming...

Страница 83: ...eference Guide 5 35 Aux Port Mode continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan AUX PORT MODE EXTERNAL HANDHELD INPUT AUX PORT MODE PIR ...

Страница 84: ... to read To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code PIR DISABLE PIR ENABLE NOTE This value added feature is a factory programmed option Conta...

Страница 85: ...figuration for new scanners NOTE A new scanner may have been shipped from the factory with a Null Interface no interface type selected to ensure system compatibility at installation In this case the correct Interface Type programming bar code must be scanned first before the scanner can be used with a POS system NOTE If the scanner s interface type must be changed always be sure that interface con...

Страница 86: ...Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED NOTE When an interface is selected the scanner loads the factory configura tion for that interface as the selection is made erasing any and all custom conf...

Страница 87: ...o ensure that the scanner reads only the bar code you intend to scan INTERFACE TYPE RS 232 STANDARD CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 88: ...ensure that the scanner reads only the bar code you intend to scan INTERFACE TYPE RS 232 WINCOR NIXDORF CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempt ing to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 89: ...ge to ensure that the scanner reads only the bar code you intend to scan INTERFACE TYPE RS 232 SINGLE CABLE CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempt ing to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 90: ... ensure that the scanner reads only the bar code you intend to scan INTERFACE TYPE IBM PORT 17 CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 91: ...age to ensure that the scanner reads only the bar code you intend to scan INTERFACE TYPE IBM USB CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 92: ... ensure that the scanner reads only the bar code you intend to scan INTERFACE TYPE USB KEYBOARD CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 93: ...T w Alternate Key Encoding 5 46 B AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Encoding 5 46 C PS 2 25 and 30 w Alternate Key Encoding 5 47 D PC XT w Standard Key Encoding 5 47 E AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding 5 48 F PS 2 25 and 30 w Standard Key Encoding 5 48 G IBM 3xxx w 122 keyboard 5 49 H IBM 3xxx w 102 keyboard 5 49 I PS 55 5530T w 104 keybo...

Страница 94: ...e scanner reads only the bar code you intend to scan INTERFACE TYPE PC KEYBOARD A INTERFACE TYPE PC KEYBOARD B CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 95: ...ure that the scanner reads only the bar code you intend to scan INTERFACE TYPE PC KEYBOARD C INTERFACE TYPE PC KEYBOARD D CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 96: ...at the scanner reads only the bar code you intend to scan INTERFACE TYPE PC KEYBOARD E INTERFACE TYPE PC KEYBOARD F CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 97: ...ure that the scanner reads only the bar code you intend to scan INTERFACE TYPE PC KEYBOARD G INTERFACE TYPE PC KEYBOARD H CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 98: ...at the scanner reads only the bar code you intend to scan INTERFACE TYPE PC KEYBOARD I INTERFACE TYPE PC KEYBOARD J CAUTION Great care should be taken to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host cable DISCONNECTED ...

Страница 99: ...only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired maximum host transmitted message length The selectable range is 0 249 data characters Labels that are longer than this length are not read Pad all single and double digit numbers with leading zeroes to yield a three digit entry 000 249 4 The scanner will automatically exit P...

Страница 100: ...e is transmitted When the feature Good Read Beep Control is enabled the scanner will beep when the data is placed in a transmission buffer When a DISABLE SCANNER command is received from the host the scanner will continue to transmit all data that is buffered To select the Number of Host Transmission Buffers 1 Scan the SWITCH bar code 2 Scan bar code below representing the desired setting You ll n...

Страница 101: ...ning the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any hex value from 00 to FF Up to 20 hex pairs can b...

Страница 102: ...ellan 2200VS and 2300HS Global Prefix continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan SET GLOBAL PREFIX TERMINATE SEQUENCE ...

Страница 103: ...of a label trans mission Three standard options are available below Contact your dealer for other alternate settings for this feature No Global Suffix CR Carriage Return CR LF Carriage Return Line Feed To set the Global Suffix 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below 3 Complete the programming sequence by scanning the SWITCH bar code GLOBAL SUFFIX NO GLOBAL SUFFIX ...

Страница 104: ...ellan 2200VS and 2300HS Global Suffix continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan GLOBAL SUFFIX CR GLOBAL SUFFIX CR LF ...

Страница 105: ... Codabar for IBM Port 9B To enable disable the IBM Transmit Labels in Code 39 Format feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code IBM TRANSMIT LABELS I...

Страница 106: ...tting to enable all scanners to communicate Options are Fixed Position Scanner Handheld Scanner To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code IB...

Страница 107: ...om the bar codes below and on the immediately following pages You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 BAUD RATE 1200 RS 232 BAUD RATE 2400 NOTE Single cable interfaces are limited to Baud Rate selections up to 19200 They cann...

Страница 108: ... 2200VS and 2300HS RS 232 Baud Rate continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RS 232 BAUD RATE 4800 RS 232 BAUD RATE 9600 ...

Страница 109: ...ference Guide 5 61 RS 232 Baud Rate continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RS 232 BAUD RATE 19200 RS 232 BAUD RATE 38400 ...

Страница 110: ...2200VS and 2300HS RS 232 Baud Rate continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RS 232 BAUD RATE 57600 RS 232 BAUD RATE 115200 ...

Страница 111: ...e 1 Scan the SWITCH bar code 2 Scan the bar code below representing the desired Data Bit setting You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 NUMBER OF DATA BITS 7 RS 232 NUMBER OF DATA BITS 8 ...

Страница 112: ... 1 Scan the SWITCH bar code 2 Scan the bar code below representing the desired Stop Bit setting You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 NUMBER OF STOP BITS 1 RS 232 NUMBER OF STOP BITS 2 ...

Страница 113: ...EN RS 232 PARITY ODD To set this feature 1 Scan the SWITCH bar code 2 Scan the bar code below or on the following pages representing the desired Parity setting You ll need to cover any unused bar codes as well as facing pages to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 PARITY NONE ...

Страница 114: ...ellan 2200VS and 2300HS RS 232 Parity continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RS 232 PARITY EVEN RS 232 PARITY ODD ...

Страница 115: ...ner to read and transmit data While the CTS line is inactive scan ner remains in a host disabled state following a successful label transmission the CTS signal must transition to inactive and then to active to enable scanning for the next label To set this feature 1 Scan the SWITCH bar code 2 Scan bar code below or from the following page for the desired set ting You ll need to cover any unused ba...

Страница 116: ...dware Control continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RS 232 HARDWARE CONTROL ENABLE CTS FLOW CONTROL RS 232 HARDWARE CONTROL ENABLE CTS SCAN CONTROL ...

Страница 117: ...nd the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired delay The selectable range is 0 100 which is the delay in 10 millisecond increments Pad all single and double digit numbers with leading zeroes to yield a three digit entry 000 100 Examples 001 10ms 005 50ms 040 400ms 100 1...

Страница 118: ... the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 SOFTWARE FLOW CONTROL DISABLE RS 232 SOFTWARE FLOW CONTROL ENABLE NOTE This item will be ignored when the feature RS 232 NAK Character is enabled ...

Страница 119: ...set via RS 232 Host Echo Quiet Interval The scanner can be set to observe this delay before sending its data in order to avoid RS 232 transmission conflicts To enable disable this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to...

Страница 120: ... QUIET INTER V AL You ll need to cover any unused bar codes on this and the fac ing page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired timeout The selectable range is 0 100 which is the timeout in 10 millisecond increments Pad all single and double digit numbers with leading zeroes to yi...

Страница 121: ...s For normal operation of the interface disable this fea ture To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 IGNORE HOST COMMANDS DISABLE ...

Страница 122: ...ls To set this feature 1 Scan the SWITCH bar code 2 Scan the bar code below which represents the desired setting for this feature You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 LEVELS NORMAL RS 232 RS 232 LEVELS TTL ...

Страница 123: ...ode 2 Scan the bar code below which represents the desired setting for this feature You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 TTL INVERT DISABLE RS 232 TTL INVERT ENABLE ...

Страница 124: ...e To enable disable this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 BEEP ON ASCII BEL DISABLE RS 232 BEEP ON ASCII BEL ENABLE ...

Страница 125: ...erence Guide 5 77 RS 232 Beep on Not on File Select for the host to beep or not when a not on file condition is detected by the host This feature is also applicable to single cable RS 232 RS 232 BEEP ON NOT ON FILE DISABLE ENABLE ...

Страница 126: ...bel is sent Host Acknowledgement Enabled for Host Commands the scan ner will respond with ACK NAK when the host sends a command Label Host Enabled for both Label Transmission Host Commands To select the option for RS 232 ACK NAK Enable 1 Scan the SWITCH bar code 2 Scan the desired option from bar codes below and on the following page You ll need to cover any unused bar codes on this and the fac in...

Страница 127: ...de 5 79 RS 232 ACK NAK Enable continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RS 232 ACK NAK HOST ACKNOWLEDGEMENT RS 232 ACK NAK LABEL HOST ...

Страница 128: ...e ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for the desired character For example if ASCII A were the desired ACK character you would scan the digits 4 then 1 the ASCII corre sponding hex value 4 The scanner will automatically exit Programming Mode when the appr...

Страница 129: ...he ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for the desired character For example if ASCII A were the desired NAK character you would scan the digits 4 then 1 the ASCII corre sponding hex value 4 The scanner will automatically exit Programming Mode when the app...

Страница 130: ...set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RS 232 RETRY ON ACK NAK TIMEOUT DISABLE RS 232 RETRY ON ACK NAK TIMEOUT ENABLE ...

Страница 131: ...ng page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired timeout A setting of 0 specifies an infinite time out The remaining selectable range is 1 75 which is the timeout in 200 millisecond increments Pad all single digit numbers with a leading zero to yield a two digit entry 00 75 Examples...

Страница 132: ...nused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired number The selectable range is 0 255 resets Pad all single and double digit numbers with leading zeroes to yield a three digit entry 000 255 4 The scanner will automatically exit Programming Mode wh...

Страница 133: ...ming errors Ignore Errors recommended setting Assume ACK risk of lost label data Assume NAK risk of duplicate label To select the option for RS 232 ACK NAK Error Handling 1 Scan the SWITCH bar code 2 Scan the desired option from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete ...

Страница 134: ... ACK NAK Error Handling continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RS 232 ACK NAK ERROR HANDLING ASSUME ACK RS 232 ACK NAK ERROR HANDLING ASSUME NAK ...

Страница 135: ...uide 5 87 RS 232 Label ID Control This feature specifies whether or not Label IDs are transmitted to the host and if so whether to attach them as a prefix or suffix RS 232 LABEL ID CONTROL DISABLE RS 232 LABEL ID CONTROL ENABLE AS PREFIX ...

Страница 136: ...200VS and 2300HS RS 232 Label ID Control continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RS 232 LABEL ID CONTROL ENABLE AS SUFFIX ...

Страница 137: ...than repeat them in this section as Single Cable options please find them referenced as follows RS 232 Baud Rate on page 5 59 RS 232 Number of Data Bits on page 5 63 RS 232 Number of Stop Bits on page 5 64 RS 232 Parity on page 5 65 RS 232 Software Flow Control on page 5 70 RS 232 Beep on Not on File on page 5 77 RS 232 Beep on Not on File on page 5 77 RS 232 Label ID Control on page 5 87 ...

Страница 138: ...ion 1 RTS is held in high state and CTS is ignored Option 2 Assert RTS and wait for CTS to be asserted Option 3 Assert RTS and ignore CTS Option 4 RTS held low wait for CTS to be asserted Option 5 RTS held high wait for CTS to be asserted To set this feature 1 Scan the SWITCH bar code 2 Scan a bar code below or on the following pages representing the desired option You ll need to cover any unused ...

Страница 139: ...uide 5 91 Single Cable RS 232 RTS CTS Selection continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RTS CTS SELECTION OPTION 2 RTS CTS SELECTION OPTION 3 ...

Страница 140: ...0HS Single Cable RS 232 RTS CTS Selection continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan RTS CTS SELECTION OPTION 4 RTS CTS SELECTION OPTION 5 ...

Страница 141: ...re 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code SINGLE CABLE RS 232 USE BCC DISABLE SINGLE CABLE RS 232 USE BCC ENABLE ...

Страница 142: ...an the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code SINGLE CABLE RS 232 USE ACK NAK DISABLE SINGLE CABLE RS 232 USE ACK NAK ENABLE ...

Страница 143: ...re 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code SINGLE CABLE RS 232 USE STX DISABLE SINGLE CABLE RS 232 USE STX ENABLE ...

Страница 144: ...ent the decimal designation for the desired character A table containing the ASCII Character Set and their corresponding decimal values is available in the inside back cover of this manual ASCII parameters must be input by scanning decimal digits for each character Pad all numbers with leading zeroes to yield a three digit entry 001 127 Thus to set a single character value of A bar codes containin...

Страница 145: ...re 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code SINGLE CABLE RS 232 USE ETX DISABLE SINGLE CABLE RS 232 USE ETX ENABLE ...

Страница 146: ...nt the decimal designation for the desired character A table containing the ASCII Character Set and their corresponding decimal values is available in the inside back cover of this manual ASCII parameters must be input by scanning decimal digits for each character Pad all numbers with leading zeroes to yield a three digit entry 001 127 Thus to set a single character value of A bar codes containing...

Страница 147: ...rameters in the order listed Connect to a Laptop No Keyboard Attached PC Keyboard Wedge ONLY Send Control Function Characters Caps Lock Country Mode Keyboard Wedge Intercharacter Delay PC Keyboard Wedge ONLY Quiet Interval PC Keyboard Wedge ONLY NOTE If the transmission parameters are configured such that a label results in no actual data to send the label will be accepted beeped and no data trans...

Страница 148: ... If a keyboard is attached enable Keyboard Attached Laptop no external keyboard provides the acknowledge signal to the PC when the scanner is connected to a laptop computer or when the scanner is operated with no external keyboard Keyboard attached is enabled when the scanner is connected to a standard PC with an external keyboard LAPTOP NO EXTERNAL KEYBOARD KEYBOARD ATTACHED NOTE This feature app...

Страница 149: ...aracters disabling this feature limits transmis sion of ASCII characters to the following Only ASCII characters between 20h 127h plus Carriage Return CR 0Dh BackSpace BS 08h Right Tab HT 09h Left Tab 0Bh Esc 1Bh Send Function Character transmits characters 00H IFH accord ing to special function key mapping Scan the bar code belows below to select the applicable option for con necting to a laptop o...

Страница 150: ... 2300HS Send Control Function Characters continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan DISABLE CONTROL CHARACTERS SEND FUNCTION CHARACTER ...

Страница 151: ... normal format Caps Lock On sends character data to the host in reverse case a z A Z A Z a z Use this feature if your keyboard s caps lock key is on Caps Lock Shift Lock sends character data to the host in shifted case Use this feature if you choose to use the keyboard with the shift lock key left on For use with interface type G IBM 3xxx 122 keyboard ONLY CAPS LOCK OFF CAPS LOCK ON ...

Страница 152: ...04 Magellan 2200VS and 2300HS Caps Lock continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan CAPS LOCK CAPS LOCK SHIFT LOCK ...

Страница 153: ...following country languages can be selected when configured for wedge I F Type E or USB Keyboard Scan the bar code below to select the desired country COUNTRY MODE USA COUNTRY MODE BELGIUM USA France Portugal Japanese 106 Key Belgium Germany Spain Britain Italy Sweden Denmark Norway Switzerland ...

Страница 154: ...llan 2200VS and 2300HS Country Mode continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan COUNTRY MODE BRITAIN COUNTRY MODE DENMARK ...

Страница 155: ...terfaces Product Reference Guide 5 107 Country Mode continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan COUNTRY MODE FRANCE COUNTRY MODE GERMANY ...

Страница 156: ...ellan 2200VS and 2300HS Country Mode continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan COUNTRY MODE ITALY COUNTRY MODE NORWAY ...

Страница 157: ...terfaces Product Reference Guide 5 109 Country Mode continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan COUNTRY MODE PORTUGAL COUNTRY MODE SPAIN ...

Страница 158: ...an 2200VS and 2300HS Country Mode continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan COUNTRY MODE SWEDEN COUNTRY MODE SWITZERLAND ...

Страница 159: ...rd Interfaces Product Reference Guide 5 111 Country Mode continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan COUNTRY MODE JAPANESE 106 KEY ...

Страница 160: ...y between each character before it is sent to the host This time delay is used to control the flow of data from the scanner Use these labels to select the desired Intercharacter Delay KEYBOARD WEDGE INTERCHARACTER DELAY NONE KEYBOARD WEDGE INTERCHARACTER DELAY 10 MILLISECONDS NOTE This feature applies to PC Keyboard Wedge ONLY ...

Страница 161: ...oard Wedge Intercharacter Delay continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan KEYBOARD WEDGE INTERCHARACTER DELAY 20 MILLISECONDS KEYBOARD WEDGE INTERCHARACTER DELAY 30 MILLISECONDS ...

Страница 162: ...character Delay continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan KEYBOARD WEDGE INTERCHARACTER DELAY 40 MILLISECONDS KEYBOARD WEDGE INTERCHARACTER DELAY 60 MILLISECONDS ...

Страница 163: ...ard Wedge Intercharacter Delay continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan KEYBOARD WEDGE INTERCHARACTER DELAY 80 MILLISECONDS KEYBOARD WEDGE INTERCHARACTER DELAY 100 MILLISECONDS ...

Страница 164: ...et Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host QUIET INTERVAL 10 MILLISECONDS QUIET INTERVAL 20 MILLISECONDS NOTE This feature applies to PC Keyboard Wedge ONLY ...

Страница 165: ...duct Reference Guide 5 117 Quiet Interval continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan QUIET INTERVAL 50 MILLISECONDS QUIET INTERVAL 100 MILLISECONDS ...

Страница 166: ...and 2300HS Quiet Interval continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan QUIET INTERVAL 200 MILLISECONDS QUIET INTERVAL 500 MILLISECONDS ...

Страница 167: ...ard Interfaces Product Reference Guide 5 119 Quiet Interval continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan QUIET INTERVAL ONE SECOND ...

Страница 168: ...on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code UPC A DISABLE UPC A ENABLE NOTE If the scanner s interface type must be changed always be sure that interface configuration is the FIRST item scanned during a program ming session Changing an interface type resets ALL other configura ...

Страница 169: ...u ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code UPC A NUMBER SYSTEM CHARACTER TRANSMISSION DISABLE UPC A NUMBER SYSTEM CHARACTER TRANSMISSION ENABLE NOTE This feature MUST be enabled for IBM interfaces for proper function This item is ignored...

Страница 170: ...enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code UPC A CHECK CHARACTER TRANSMISSION DISABLE UPC A CHECK CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full Label Edit is ena...

Страница 171: ...n the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EXPAND UPC A TO EAN JAN 13 DISABLE EXPAND UPC A TO EAN JAN 13 ENABLE ...

Страница 172: ...To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code UPC EAN AIM ID DISABLE UPC EAN AIM ID ENABLE ...

Страница 173: ...acters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any he...

Страница 174: ... desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for...

Страница 175: ...desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for ...

Страница 176: ...ired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for thi...

Страница 177: ...et this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code UPC E DISABLE UPC E ENABLE ...

Страница 178: ...enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code UPC E NUMBER SYSTEM CHARACTER TRANSMISSION DISABLE UPC E NUMBER SYSTEM CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full L...

Страница 179: ...nable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code UPC E CHECK CHARACTER TRANSMISSION DISABLE UPC E CHECK CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full Label Edit is enab...

Страница 180: ...Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EXPAND UPC E TO UPC A DISABLE EXPAND UPC E TO UPC A ENABLE ...

Страница 181: ...n the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EXPAND UPC E TO EAN JAN 13 DISABLE EXPAND UPC E TO EAN JAN 13 ENABLE ...

Страница 182: ...racters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any h...

Страница 183: ...desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for ...

Страница 184: ... desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for...

Страница 185: ...red Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this...

Страница 186: ...o set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN 13 DISABLE EAN 13 ENABLE ...

Страница 187: ...enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN 13 FIRST CHARACTER TRANSMISSION DISABLE EAN 13 FIRST CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full Label Edit is e...

Страница 188: ...e enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN 13 CHECK CHARACTER TRANSMISSION DISABLE EAN 13 CHECK CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full Label Edit is...

Страница 189: ...To set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN 13 ISBN Conversion DISABLE EAN 13 ISBN Conversion ENABLE ...

Страница 190: ...abel ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this opti...

Страница 191: ...e desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range fo...

Страница 192: ...e desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range fo...

Страница 193: ...sired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for th...

Страница 194: ...To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code BOOKLAND AIM ID DISABLE BOOKLAND AIM ID ENABLE ...

Страница 195: ...haracters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any...

Страница 196: ...o set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN 8 DISABLE EAN 8 ENABLE ...

Страница 197: ... enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN 8 CHECK CHARACTER TRANSMISSION DISABLE EAN 8 CHECK CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full Label Edit is en...

Страница 198: ... the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EXPAND EAN JAN 8 TO EAN JAN 13 DISABLE EXPAND EAN JAN 8 TO EAN JAN 13 ENABLE ...

Страница 199: ...bel ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this optio...

Страница 200: ... desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for...

Страница 201: ...desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for ...

Страница 202: ...sired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for th...

Страница 203: ...d most aggressive To set this feature 1 Scan the SWITCH bar code 2 Scan the bar code representing the desired option on the following pages You ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CAUTION Use caution when setting this feature as the aggressive ...

Страница 204: ...8 Decoding Levels continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan EAN 8 DECODING LEVELS VERY CONSERVATIVE EAN 8 DECODING LEVELS SLIGHTLY MORE AGGRESSIVE ...

Страница 205: ... 8 Decoding Levels continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan EAN 8 DECODING LEVELS MODERATELY AGGRESSIVE EAN 8 DECODING LEVELS VERY AGGRESSIVE ...

Страница 206: ...lan 2200VS and 2300HS Other UPC EAN Options The following pages contain other selectable features for UPC EAN sym bologies UPC EAN Reconstruction Price Weight Check Enable EAN Two Label Addons UPC A and EAN 13 Decoding Levels ...

Страница 207: ...vironments with in store printed labels To set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan Complete the programming sequence by scanning the SWITCH bar code UPC EAN RECONSTRUCTION DISABLE UPC EAN RECONSTRUCTION EN...

Страница 208: ...the SWITCH bar code 2 Scan the bar code representing the desired option below or on the following pages You ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code PRICE WEIGHT CHECK DISABLE 1 Price Weight Check generally applies to UPC A labels with a Number Syst...

Страница 209: ...161 Price Weight Check continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan PRICE WEIGHT CHECK 4 DIGIT PRICE WEIGHT PRICE WEIGHT CHECK 5 DIGIT PRICE WEIGHT ...

Страница 210: ...ight Check continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan PRICE WEIGHT CHECK 4 DIGIT EUROPEAN PRICE WEIGHT PRICE WEIGHT CHECK 5 DIGIT EUROPEAN PRICE WEIGHT ...

Страница 211: ...ode 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN TWO LABEL DISABLE EAN TWO LABEL ENABLE NOTE Contact Customer Support for details about advanced programming for this feature ...

Страница 212: ... can be read which include 2 Digit or 5 Digit Supplementals however it is not required that addons be included in bar codes To set this feature 1 Scan the SWITCH bar code 2 Scan the bar code representing the desired option on this and the following page You ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan 3 Complete the pro...

Страница 213: ...uct Reference Guide 5 165 Addons continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan ADDONS OPTIONAL 2 DIGIT AND 5 DIGIT SUPPLEMENTAL ...

Страница 214: ...an speed most aggressive To set this feature 1 Scan the SWITCH bar code 2 Scan the bar code representing the desired option on the following pages You ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CAUTION Use caution when setting this feature as the aggr...

Страница 215: ... 13 Decoding Levels continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan UPC A EAN 13 DECODING LEVELS VERY CONSERVATIVE UPC A EAN 13 DECODING LEVELS SLIGHTLY MORE AGGRESSIVE ...

Страница 216: ...13 Decoding Levels continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan UPC A EAN 13 DECODING LEVELS MODERATELY AGGRESSIVE UPC A EAN 13 DECODING LEVELS VERY AGGRESSIVE ...

Страница 217: ...nable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code GTIN DISABLE GTIN ENABLE NOTE If add on information is present on the base label prior to the conversion taking place the add on information will be appended to...

Страница 218: ...racters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any h...

Страница 219: ...hat rep resent the desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The se...

Страница 220: ...that rep resent the desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The s...

Страница 221: ...that rep resent the desired Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The s...

Страница 222: ...bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS 14 DISABLE RSS 14 ENABLE NOTE This value added feature is a factory programmed option Contact your dealer for information about upgrading your system to include this advance...

Страница 223: ...n the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS 14 CHECK CHARACTER TRANSMISSION DISABLE RSS 14 CHECK CHARACTER TRANSMISSION ENABLE ...

Страница 224: ...ture 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS 14 EAN 128 EMULATION DISABLE RSS 14 EAN 128 EMULATION ENABLE ...

Страница 225: ... the 2D component will be discarded To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS 14 2D COMPONENT DISABLE RSS 14 2D COMPONENT ENABLE ...

Страница 226: ...o set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS 14 AIM ID DISABLE RSS 14 AIM ID ENABLE ...

Страница 227: ...abel ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this opti...

Страница 228: ...bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS EXPANDED DISABLE RSS EXPANDED ENABLE NOTE This value added feature is a factory programmed option Contact your dealer for information about upgrading your system to include ...

Страница 229: ...an the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS EXPANDED EAN 128 EMULATION DISABLE RSS EXPANDED EAN 128 EMULATION ENABLE ...

Страница 230: ... the 2D component will be discarded To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS EXPANDED 2D COMPONENT DISABLE RSS EXPANDED 2D COMPONENT EN...

Страница 231: ...r To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS EXPANDED AIM ID DISABLE RSS EXPANDED AIM ID ENABLE ...

Страница 232: ... ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option i...

Страница 233: ...his and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code RSS EXPANDED LENGTH CONTROL VARIABLE LENGTH RSS EXPANDED LENGTH CONTROL FIXED LENGTH NOTE If variable length control was selected you must now set the features RSS Expanded Maximum Label Length and RSS Expanded Mini mum Label Length If fi...

Страница 234: ...de you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired maximum label length The selectable range for this option is 00 to 74 Pad all single digit numbers with a leading zero to yield a two digit entry 00 74 4 Complete the programming sequence by scanning the SWITCH bar code SET RSS EXPANDED MAXIMUM LABEL LENGTH NOTE Length in this case include...

Страница 235: ...ar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired minimum label length The selectable range for this option is 00 to 74 Pad all single digit numbers with a leading zero to yield a two digit entry 00 74 4 Complete the programming sequence by scanning the SWITCH bar code SET RSS EXPANDED MINIMUM LABEL LENGTH NOTE Length in this case in...

Страница 236: ...g page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 00 to 74 Pad all single digit numbers with a leading zero to yield a two digit entry 00 74 4 Complete the programming sequence by scanning the SWITCH bar code SET RSS EXPANDED ...

Страница 237: ...ner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 00 to 74 Pad all single digit numbers with a leading zero to yield a two digit entry 00 74 4 Complete the programming sequence by scanning the SWITCH bar code SET RSS EXPANDED FIXED LENGTH 2 NOTE This appli...

Страница 238: ...set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 39 DISABLE CODE 39 ENABLE ...

Страница 239: ... enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 39 START STOP CHARACTER TRANSMISSION DISABLE CODE 39 START STOP CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full La...

Страница 240: ...e 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 39 CHECK CHARACTER CALCULATION DISABLE CODE 39 CHECK CHARACTER CALCULATION ENABLE NOTE If check calculation...

Страница 241: ...he enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 39 CHECK CHARACTER TRANSMISSION DISABLE CODE 39 CHECK CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full Label Edit...

Страница 242: ...set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 39 FULL ASCII DISABLE CODE 39 FULL ASCII ENABLE ...

Страница 243: ...o set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 39 AIM ID DISABLE CODE 39 AIM ID ENABLE ...

Страница 244: ...haracters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any...

Страница 245: ...bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 39 LENGTH CONTROL VARIABLE LENGTH CODE 39 LENGTH CONTROL FIXED LENGTH NOTE If variable length control was selected you must now set the features Code 39 Maximum Label Length and Code 39 Minimum Label Length If fixed len...

Страница 246: ... appropriate digits from the keypad in Appendix C that rep resent the desired maximum label length The selectable range for this option is 00 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 00 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 39 MAXIMUM LABEL LENGTH NOTE Length in this case includes check data and ASCII characters but...

Страница 247: ...he appropriate digits from the keypad in Appendix C that rep resent the desired minimum label length The selectable range for this option is 00 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 00 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 39 MINIMUM LABEL LENGTH NOTE Length in this case includes check data and ASCII characters b...

Страница 248: ...y the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 00 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 00 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 39 FIXED LENGTH 1 NOTE This applies when Code 39 Le...

Страница 249: ...e bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 00 no second fixed length or 01 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 00 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 39 FIXED LENGTH 2 NOTE Thi...

Страница 250: ...canner s software and the data will be decoded if all bar code proofing requirements are met To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan Complete the programming sequence by scanning the SWITCH bar code CODE 39...

Страница 251: ...els To set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code PHARMACODE 39 DISABLE PHARMACODE 39 ENABLE ...

Страница 252: ...he enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code PHARMACODE 39 START STOP CHARACTER TRANSMISSION DISABLE PHARMACODE 39 START STOP CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced f...

Страница 253: ...e enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code PHARMACODE 39 CHECK CHARACTER TRANSMISSION DISABLE PHARMACODE 39 CHECK CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full...

Страница 254: ...l ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option ...

Страница 255: ... set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 128 DISABLE CODE 128 ENABLE ...

Страница 256: ...Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 128 TRANSMIT FUNCTION CHARACTERS DISABLE CODE 128 TRANSMIT FUNCTION CHARACTERS ENABLE NOTE Disabled is the recommended setting for all int...

Страница 257: ... Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CONVERT CODE 128 TO CODE 39 DISABLE CONVERT CODE 128 TO CODE 39 ENABLE ...

Страница 258: ...To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 128 AIM ID DISABLE CODE 128 AIM ID ENABLE ...

Страница 259: ...characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is an...

Страница 260: ...r codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 128 LENGTH CONTROL VARIABLE LENGTH CODE 128 LENGTH CONTROL FIXED LENGTH NOTE If variable length control was selected you must now set the features Code 128 Maximum Label Length and Code 128 Minimum Label Length If fixed l...

Страница 261: ...e digits from the keypad in Appendix C that rep resent the desired maximum label length The selectable range for this option is 01 to 80 Pad all single digit numbers with a leading zero to yield a two digit entry 01 80 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 128 MAXIMUM LABEL LENGTH NOTE Length in this case includes function characters and data charac ters but ...

Страница 262: ...te digits from the keypad in Appendix C that rep resent the desired minimum label length The selectable range for this option is 01 to 80 Pad all single digit numbers with a leading zero to yield a two digit entry 01 80 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 128 MINIMUM LABEL LENGTH NOTE Length in this case includes function characters and data characters but ...

Страница 263: ... page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 01 to 80 Pad all single digit numbers with a leading zero to yield a two digit entry 01 80 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 128 FIXED...

Страница 264: ...eads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 01 to 80 Pad all single digit numbers with a leading zero to yield a two digit entry 01 80 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 128 FIXED LENGTH 2 NOTE This applies when C...

Страница 265: ...scanner s software and the data will be decoded if all bar code proofing requirements are met To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan Complete the programming sequence by scanning the SWITCH bar code CODE 1...

Страница 266: ...set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN 128 DISABLE EAN 128 ENABLE ...

Страница 267: ...To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code EAN 128 AIM ID DISABLE EAN 128 AIM ID ENABLE ...

Страница 268: ...haracters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any...

Страница 269: ...rleaved 2 of 5 labels To set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code I 2 OF 5 DISABLE I 2 OF 5 ENABLE ...

Страница 270: ...ow You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code I 2 of 5 CHECK CHARACTER CALCULATION DISABLE I 2 of 5 CHECK CHARACTER CALCULATION ENABLE NOTE If check character calculation is disabled the risk is increased that a mis read can occur When...

Страница 271: ...ar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code I 2 of 5 CHECK CHARACTER TRANSMISSION DISABLE I 2 of 5 CHECK CHARACTER TRANSMISSION ENABLE NOTE This feature applies only when I 2 of 5 Check Character Calculation is enabled Thi...

Страница 272: ...o set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code I 2 of 5 AIM ID DISABLE I 2 of 5 AIM ID ENABLE ...

Страница 273: ...d Label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this o...

Страница 274: ...r codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code I 2 OF 5 LENGTH CONTROL VARIABLE LENGTH I 2 OF 5 LENGTH CONTROL FIXED LENGTH NOTE If variable length control was selected you must now set the features I 2 of 5 Maximum Label Length and I 2 of 5 Minimum Label Length If fixed l...

Страница 275: ...n the appropriate digits from the keypad in Appendix C that rep resent the desired maximum label length The selectable range for this option is 02 to 50 even numbers only Pad all single digit num bers with a leading zero to yield a two digit entry 02 50 4 Complete the programming sequence by scanning the SWITCH bar code SET I 2 OF 5 MAXIMUM LABEL LENGTH NOTE Length in this case includes check and ...

Страница 276: ...ropriate digits from the keypad in Appendix C that rep resent the desired minimum label length The selectable range for this option is 02 to 50 even numbers only Pad all single digit num bers with a leading zero to yield a two digit entry 02 50 4 Complete the programming sequence by scanning the SWITCH bar code SET I 2 OF 5 MINIMUM LABEL LENGTH NOTE Length in this case includes check and data char...

Страница 277: ... page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 02 to 50 even numbers only Pad all single digit numbers with a leading zero to yield a two digit entry 02 50 4 Complete the programming sequence by scanning the SWITCH bar code ...

Страница 278: ...e bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 00 or 02 to 50 even numbers only Pad all single digit numbers with a leading zero to yield a two digit entry 02 50 4 Complete the programming sequence by scanning the SWITCH bar code SET I 2 OF 5 FIXED LENGTH 2 NOTE This ap...

Страница 279: ...ed by the scanner s software and the data will be decoded if all bar code proofing requirements are met To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan Complete the programming sequence by scanning the SWITCH bar c...

Страница 280: ...set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODABAR DISABLE CODABAR ENABLE ...

Страница 281: ... enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODABAR START STOP CHARACTER TRANSMISSION DISABLE CODABAR START STOP CHARACTER TRANSMISSION ENABLE NOTE This item is ignored when the advanced feature Full La...

Страница 282: ...d To set this feature 1 Scan the SWITCH bar code 2 Scan the bar code below or from the following page representing the desired option You ll need to cover any unused bar codes and facing pages to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODABAR START STOP CHARACTER ABCD TN E CODABAR START STOP CHARACTER A...

Страница 283: ...ar Start Stop Character Set continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan CODABAR START STOP CHARACTER abcd tn e CODABAR START STOP CHARACTER abcd abcd ...

Страница 284: ... 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODABAR START STOP CHARACTER MATCH DISABLE CODABAR START STOP CHARACTER MATCH ENABLE ...

Страница 285: ...u ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODABAR CHECK CHARACTER CALCULATION DISABLE CODABAR CHECK CHARACTER CALCULATION ENABLE NOTE If check character calculation is disabled the risk is increased that a misread can occur When disable...

Страница 286: ...elow You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODABAR CHECK CHARACTER TRANSMISSION DISABLE CODABAR CHECK CHARACTER TRANSMISSION ENABLE NOTE Applies only when Codabar Check Character Calculation is enabled This item is ignored when th...

Страница 287: ...o set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODABAR AIM ID DISABLE CODABAR AIM ID ENABLE ...

Страница 288: ...aracters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any ...

Страница 289: ...bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODABAR LENGTH CONTROL VARIABLE LENGTH CODABAR LENGTH CONTROL FIXED LENGTH NOTE If variable length control was selected you must now set the fea tures Codabar Maximum Label Length and Codabar Minimum Label Length If fixed le...

Страница 290: ...opriate digits from the keypad in Appendix C that rep resent the desired maximum label length The selectable range for this option is 03 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 03 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODABAR MAXIMUM LABEL LENGTH NOTE Length in this case includes start stop or check and data characters ...

Страница 291: ...ropriate digits from the keypad in Appendix C that rep resent the desired minimum label length The selectable range for this option is 03 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 03 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODABAR MINIMUM LABEL LENGTH NOTE Length in this case includes start stop or check and data charac ter...

Страница 292: ...digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 03 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 03 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODABAR FIXED LENGTH 1 NOTE Length in this case includes start stop or check and data characters but does not inc...

Страница 293: ...that rep resent the desired fixed label length The selectable range for this option is 00 or 03 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 03 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODABAR FIXED LENGTH 2 NOTE Length in this case includes start stop or check and data charac ters but does not include full ASCII shift characte...

Страница 294: ...canner s software and the data will be decoded if all bar code proofing requirements are met To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan Complete the programming sequence by scanning the SWITCH bar code CODABAR...

Страница 295: ...set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 93 DISABLE CODE 93 ENABLE ...

Страница 296: ...o set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 93 AIM ID DISABLE CODE 93 AIM ID ENABLE ...

Страница 297: ...haracters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option is any...

Страница 298: ...bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code CODE 93 LENGTH CONTROL VARIABLE LENGTH CODE 93 LENGTH CONTROL FIXED LENGTH NOTE If variable length control was selected you must now set the features Code 93 Maximum Label Length and Code 93 Minimum Label Length If fixed len...

Страница 299: ...propriate digits from the keypad in Appendix C that rep resent the desired maximum label length The selectable range for this option is 01 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 01 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 93 MAXIMUM LABEL LENGTH NOTE Length in this case includes data characters but does not include s...

Страница 300: ...ppropriate digits from the keypad in Appendix C that rep resent the desired minimum label length The selectable range for this option is 01 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 01 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 93 MINIMUM LABEL LENGTH NOTE Length in this case includes data characters but does not include ...

Страница 301: ...page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 01 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 01 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 93 FIXED L...

Страница 302: ...s only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 00 or 01 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 01 50 4 Complete the programming sequence by scanning the SWITCH bar code SET CODE 93 FIXED LENGTH 2 NOTE This applies when...

Страница 303: ...canner s software and the data will be decoded if all bar code proofing requirements are met To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan Complete the programming sequence by scanning the SWITCH bar code CODE 93...

Страница 304: ...set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code MSI PLESSEY DISABLE MSI PLESSEY ENABLE ...

Страница 305: ...ou ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code MSI PLESSEY CHECK CHARACTER CALCULATION DISABLE MSI PLESSEY CHECK CHARACTER CALCULATION ENABLE NOTE If check character calculation is disabled the risk is increased that a misread can occur Whe...

Страница 306: ...elow representing the desired number of MSI Plessey check characters to be calculated and verified You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code MSI PLESSEY NUMBER OF CHECK CHARACTERS 1 MSI PLESSEY NUMBER OF CHECK CHARACTERS 2 NOTE Check ...

Страница 307: ... ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code MSI PLESSEY CHECK CHARACTER TRANSMISSION DISABLE MSI PLESSEY CHECK CHARACTER TRANSMISSION ENABLE NOTE This feature applies only when MSI Plessey Check Character Calcu lation is enabled This item ...

Страница 308: ...To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code MSI PLESSEY AIM ID DISABLE MSI PLESSEY AIM ID ENABLE ...

Страница 309: ...l ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this option ...

Страница 310: ...des on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code MSI PLESSEY LENGTH CONTROL VARIABLE LENGTH MSI PLESSEY LENGTH CONTROL FIXED LENGTH NOTE If variable length control was selected you must now set the features MSI Plessey Maximum Label Length and MSI Plessey Minimum Label Length If...

Страница 311: ...appropriate digits from the keypad in Appendix C that rep resent the desired maximum label length The selectable range for this option is 4 to 16 Pad all single digit numbers with a leading zero to yield a two digit entry 04 16 4 Complete the programming sequence by scanning the SWITCH bar code SET MSI PLESSEY MAXIMUM LABEL LENGTH NOTE Length in this case includes check and data characters but doe...

Страница 312: ...the appropriate digits from the keypad in Appendix C that rep resent the desired minimum label length The selectable range for this option is 4 to 16 Pad all single digit numbers with a leading zero to yield a two digit entry 04 16 4 Complete the programming sequence by scanning the SWITCH bar code SET MSI PLESSEY MINIMUM LABEL LENGTH NOTE Length in this case includes check and data characters but...

Страница 313: ...ing page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 4 to 16 Pad all single digit numbers with a leading zero to yield a two digit entry 04 16 4 Complete the programming sequence by scanning the SWITCH bar code SET MSI PLESSEY ...

Страница 314: ... only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 0 zero or 4 to 16 Pad all single digit numbers with a leading zero to yield a two digit entry 00 04 16 4 Complete the programming sequence by scanning the SWITCH bar code SET MSI PLESSEY FIXED LENGTH 2 NOTE This app...

Страница 315: ...the scanner s software and the data will be decoded if all bar code proofing requirements are met To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan Complete the programming sequence by scanning the SWITCH bar code MS...

Страница 316: ...set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code STANDARD 2 OF 5 DISABLE STANDARD 2 OF 5 ENABLE ...

Страница 317: ...ow You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code STANDARD 2 of 5 CHECK CHARACTER CALCULATION DISABLE STANDARD 2 of 5 CHECK CHARACTER CALCULATION ENABLE NOTE If check character calculation is disabled the risk is increased that a mis read ...

Страница 318: ...l need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code STANDARD 2 of 5 CHECK CHARACTER TRANSMISSION DISABLE STANDARD 2 of 5 CHECK CHARACTER TRANSMISSION ENABLE NOTE This feature applies only when Standard 2 of 5 Check Character Cal culation is enabled ...

Страница 319: ...er To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code STANDARD 2 of 5 AIM ID DISABLE STANDARD 2 of 5 AIM ID ENABLE ...

Страница 320: ...bel ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character Thus to set a two character value of AB bar codes containing the digits 4 1 4 and 2 must be scanned The selectable range for this optio...

Страница 321: ... this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Complete the programming sequence by scanning the SWITCH bar code STANDARD 2 OF 5 LENGTH CONTROL VARIABLE LENGTH STANDARD 2 OF 5 LENGTH CONTROL FIXED LENGTH NOTE If variable length control was selected you must now set the features Standard 2 of 5 Maximum Label Length and Standard 2 of 5 Mini mum Labe...

Страница 322: ...propriate digits from the keypad in Appendix C that rep resent the desired maximum label length The selectable range for this option is 01 to 50 even numbers only Pad all single digit num bers with a leading zero to yield a two digit entry 01 50 4 Complete the programming sequence by scanning the SWITCH bar code SET STANDARD 2 OF 5 MAXIMUM LABEL LENGTH NOTE Length in this case includes check and d...

Страница 323: ...the appropriate digits from the keypad in Appendix C that rep resent the desired minimum label length The selectable range for this option is 01 to 50 even numbers only Pad all single digit num bers with a leading zero to yield a two digit entry 01 50 4 Complete the programming sequence by scanning the SWITCH bar code SET STANDARD 2 OF 5 MINIMUM LABEL LENGTH NOTE Length in this case includes check...

Страница 324: ... ing page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 1 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 01 50 4 Complete the programming sequence by scanning the SWITCH bar code SET STANDARD 2 ...

Страница 325: ...scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the keypad in Appendix C that rep resent the desired fixed label length The selectable range for this option is 1 to 50 Pad all single digit numbers with a leading zero to yield a two digit entry 01 50 4 Complete the programming sequence by scanning the SWITCH bar code SET STANDARD 2 OF 5 FIXED LENGTH 2 NOTE This...

Страница 326: ... decoded if all bar code proofing requirements are met To set this feature 1 Scan the SWITCH bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan Complete the programming sequence by scanning the SWITCH bar code STANDARD 2 OF 5 STITCHING DISABLE STANDARD 2 ...

Страница 327: ...indicators for both models The descriptions following identify the use or function of each compo nent Figure A 1 Scanner Controls and Indicators Speaker Scan Window Upper Scan Window Lower Scan Window Indicator LED plus Volume Tone Push Button Volume Tone Push Button Indicator LED Model 2200VS Model 2300HS Top Cover ...

Страница 328: ...e When the loudest volume is reached a repeated press of the push button cycles volume back to the lowest setting then volume increases on subse quent press es Four volume levels are available Hold then release when the beeper sounds Increments tone Press the push button for approximately 2 seconds then release Each time this is done the beeper will sound at one of three tones Stop when the desire...

Страница 329: ...ation Scanner Green LED flashes slowly The scanner motor and or laser have automati cally switched off and the unit has entered Sleep Mode due to extended inactivity Host Disabled Scanner Green LED 1 second off 1 10 second on Host has disabled scanning Field Replace able Unit FRU Warning Error Mode Audible low tone 1 second LED flashes continuously Serves notice that a fatal FRU failure has been d...

Страница 330: ...A 4 Magellan 2200VS and 2300HS NOTES ...

Страница 331: ...n enabling you to create standard interface cables for use in interconnecting the scanner external handheld scanner and POS terminal General Specifications Wire Requirements Cable length should not exceed 15 feet Wire gauge Standard for RJ 45 connectors 28 26 AWG If run exceeds 15 feet we recommend 26 AWG wire size ...

Страница 332: ...nout Table B 1 RS 232 Cable Pinouts PIN FUNCTION DESCRIPTION 1 DTR Data Terminal Ready 2 CTS in Clear To Send input 3 N C No Connection 4 RTS out Request To Send output 5 RxD in Receive Data Input 6 TxD out Transmit Data output 7 N C No Connection 8 5V out 5V out 9 GND Signal Ground 10 N C No Connection ...

Страница 333: ...5 10 Position Cable Pinout Table B 2 PIN FUNCTION DESCRIPTION 1 5V pullup 5V pullup 2 N C No Connection 3 N C No Connection 4 Serial I O B Serial Data 5 N C No Connection 6 Serial I O A Serial Data 7 N C No Connection 8 5V out 5V out 9 Ground Signal Ground 10 N C No Connection ...

Страница 334: ...ector Hardware RJ45 10 Position Cable Pinout Table B 3 PIN FUNCTION DESCRIPTION 1 5V pullup 5V pullup 2 N C No Connection 3 N C No Connection 4 USB D USB D 5 N C No Connection 6 USB D USB D 7 N C No Connection 8 5V out 5V out 9 GND Signal Ground 10 N C No Connection ...

Страница 335: ...Table B 4 PIN FUNCTION DESCRIPTION 1 DTR Data Terminal Ready 2 CTS in Clear To Send input 3 N C No Connection Reserved 4 RTS out Request To Send output 5 RxD in Receive Data Input 6 TxD out Transmit Data output 7 EAS_GOOD READ Special use Good Read 8 5V out 500mA max 5V out 9 GND Signal Ground 10 SPKR OUT Speaker Out ...

Страница 336: ...B 6 Magellan 2200VS and 2300HS NOTES ...

Страница 337: ...tion to enter numbers and characters as you would select digits characters from a keypad Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 0 1 ...

Страница 338: ...enter numbers and characters as you would select digits characters from a keypad Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 2 3 ...

Страница 339: ...nter numbers and characters as you would select digits characters from a keypad Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 4 5 ...

Страница 340: ...enter numbers and characters as you would select digits characters from a keypad Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 6 7 ...

Страница 341: ...nter numbers and characters as you would select digits characters from a keypad Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 8 9 ...

Страница 342: ...enter numbers and characters as you would select digits characters from a keypad Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan A B ...

Страница 343: ...nter numbers and characters as you would select digits characters from a keypad Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan C D ...

Страница 344: ...enter numbers and characters as you would select digits characters from a keypad Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan E F ...

Страница 345: ...Contact Tech Support for more details COMMAND ASCII HEX COMMENT Enable Scanner E 0x45 Disable Scanner D 0x44 Reset Scanner R 0x52 Not On File Indication F 0x46 Long series of beeps Beep Good Read Tone B 0x42 Beeps if Good Read Beep is enabled Force Good Read Tone 0x01 Beeps regardless of beep setting Bel 0x07 Force Good Read Tone Identification request i 0x69 Returns long responsea Health request ...

Страница 346: ...D 2 Magellan 2200VS and 2300HS NOTES ...

Страница 347: ...10 min 40 10 min Green LED Idle State 2 on dim 2 on dim 2 on dim 2 on dim 2 on dim 2 on dim 2 on dim 2 on dim Scanner But ton Options 1 vol tone reset 1 vol tone reset 1 vol tone reset 1 vol tone reset 1 vol tone reset 1 vol tone reset 1 vol tone reset 1 vol tone reset Power up Beep Control 1 beep 1 beep 1 beep 1 beep 1 beep 1 beep 1 beep 1 beep Good Read Beep Control 1 enable 1 enable 1 enable 1 ...

Страница 348: ...able 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable PC Keyboard Wedge Inter face Selection Wedge E Connect to a Laptop No Keyboard Attached 0 disable Send Control Function Char acters 0 disable 0 disable Caps Lock 0 Caps lock OFF 0 Caps lock OFF Country Mode A U S Keyboard Wedge Inter character Delay 00 no delay Quiet Interval 1 10 msec Maximum Host Transmit ted Message Leng...

Страница 349: ...0 1 stop bit 0 1 stop bit 0 1 stop bit RS 232 Parity 0 none 0 none 2 odd 2 odd RS 232 Hard ware Control 0 disable 0 disable 1 enable CTS flow RS 232 Inter character Delay 0 none 0 none 0 none RS 232 Soft ware Flow Control 0 disable 0 disable 0 disable 0 disable RS 232 Host Echo 0 disable 0 disable RS 232 Host Echo Quiet Interval 1 10ms 1 10ms RS 232 Ignore Host Com mands 0 disable 0 disable 0 disa...

Страница 350: ... ACK NAK Timeout 1 enable 1 enable 1 enable RS 232 ACK NAK Timeout Value 1 200ms 1 200ms 1 200ms RS 232 ACK NAK Retry Count 3 resets 3 resets 3 resets RS 232 ACK NAK Error Handling 0 ignore errors 0 ignore errors 0 ignore errors RS 232 Label ID Control 1 enable as prefix 1 enable as prefix 1 enable as prefix 1 enable as prefix Single Cable RS 232 RTS CTS Selection Option 5 Single Cable RS 232 Use ...

Страница 351: ...ansmission 1 enable 1 enable 1 enable 0 disable 1 enable 1 enable 1 enable 1 enable ExpandUPC A to EAN 13 0 disable 0 disable 1 enable 0 disable 0 disable 0 disable 0 disable 0 disable UPC EAN AIM ID 0 disable 0 disable 0 disable 0 disable 0 disable UPC A Label ID 4100 A 4100 A 4100 A 4100 A 4100 A 4100 A UPC A 2 Digit Supplemental Label ID 4100 A 4100 A 4100 A 4100 A 4100 A 4100 A UPC A 5 Digit S...

Страница 352: ...4500 E 4500 E 4300 C 4500 E 4500 E 4500 E UPC E 2 Digit Supplemental Label ID 4500 E 4500 E 4300 C 4500 E 4500 E 4500 E UPC E 5 Digit Supplemental Label ID 4500 E 4500 E 4300 C 4500 E 4500 E 4500 E UPC E 128 Supplemental Label ID 4500 E 4500 E 4300 C 4500 E 4500 E 4500 E EAN 13 Enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable EAN 13 First Character Transmission 1 enab...

Страница 353: ...nable 1 enable EAN 8 Check Character Transmission 1 enable 1 enable 1 enable 0 disable 1 enable 1 enable 1 enable 1 enable Expand EAN 8 to EAN 13 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable EAN 8 Label ID 4646 FF 4646 FF 4200 B 4646 FF 4646 FF 4646 FF EAN 8 2 Digit Supplemental Label ID 4646 FF 4646 FF 4200 B 4646 FF 4646 FF 4646 FF EAN 8 5 Digit Supplemental La...

Страница 354: ...5 4700 G 4700 G 4700 G 4700 G 4700 G 4700 G GTIN C128 Label ID 4700 G 4700 G 4700 G 4700 G RSS 14 Check Character Transmission 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable RSS 14 EAN 128 Emulation 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable RSS 14 2D Component Enable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable...

Страница 355: ...nded Maximum Label Length 74 74 74 74 74 74 74 74 RSS Expanded Min imum Label Length 1 1 1 1 1 1 1 1 RSS Expanded Fixed Length 1 8 8 8 8 8 8 8 8 RSS Expanded Fixed Length 2 14 14 14 14 14 14 14 14 Code 39 Enable 1 enable 1 enable 0 disable 1 enable 1 enable 1 enable 1 enable 1 enable Code 39 Start Stop Charac ter Transmis sion 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0...

Страница 356: ...axi mum Label Length 50 50 50 50 50 50 50 50 Code 39 Mini mum Label Length 6 6 6 6 6 6 6 6 Code 39 Fixed Length 1 8 8 8 8 8 8 8 8 Code 39 Fixed Length 2 14 14 14 14 14 14 14 14 Code 39 Stitching 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable Pharmacode 39 Enable 1 enable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable Pharmacode 39 Start Stop Characte...

Страница 357: ...0 4B00 K 4233 B3 2300 2300 Code 128 Length Control 0 variable 0 variable 0 variable 0 variable 0 variable 0 variable 0 variable 0 variable Code 128 Maximum Label Length 80 80 80 80 80 80 80 80 Code 128 Mini mum Label Length 2 2 2 2 2 2 2 2 Code 128 Fixed Length 1 8 8 8 8 8 8 8 8 Code 128 Fixed Length 2 14 14 14 14 14 14 14 14 Code 128 Stitching 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable...

Страница 358: ...able 0 variable 0 variable 0 variable 0 variable I 2 of 5 Maxi mum Label Length 50 50 50 50 50 50 50 50 I 2 of 5 Mini mum Label Length 6 6 6 6 6 6 6 6 I 2 of 5 Fixed Length 1 10 10 10 10 10 10 10 10 I 2 of 5 Fixed Length 2 0 0 0 0 0 0 0 0 I 2 of 5 Stitch ing 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable Codabar Enable 0 disable 0 disable 0 disable 0 disable 0 disa...

Страница 359: ...0 Codabar Length Control 0 variable 0 variable 0 variable 0 variable 0 variable 0 variable 0 variable 0 variable Codabar Maxi mum Label Length 50 50 50 50 50 50 50 50 Codabar Mini mum Label Length 8 8 8 8 8 8 8 8 Codabar Fixed Length 1 8 8 8 8 8 8 8 8 Codabar Fixed Length 2 14 14 14 14 14 14 14 14 Codabar Stitching 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable Cod...

Страница 360: ... 0 disable 0 disable 0 disable 0 disable MSI Plessey Check Charac ter Calculation 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable MSI Plessey Number of Check Charac ters 0 1 check char 0 1 check char 0 1 check char 0 1 check char 0 1 check char 0 1 check char MSI Plessey Check Charac ter Transmis sion 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable MSI Plessey AIM ID 0 disable 0 disabl...

Страница 361: ... disable 0 disable 0 disable 0 disable 0 disable Standard 2 of 5 Check Char acter Trans mission 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable 1 enable Standard 2 of 5 AIM ID 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable Standard 2 of 5 Label ID 5300 S 5300 S 5300 S 5300 S 5300 S 5300 S 5300 S 5300 S Standard 2 of 5 Length Con trol 0 variable 0 var...

Страница 362: ...h 1 10 10 10 10 10 10 10 10 Standard 2 of 5 Fixed Length 2 0 0 0 0 0 0 0 0 Standard 2 of 5 Stitching 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable 0 disable Table E 2 Aux RS 232 Wincor Nixdorf Single Cable IBM 17 IBM USB USB Keybd PC KBW ...

Страница 363: ...on and de asserted after label transmission is complete No other flow control mecha nisms are required or supported Symbologies requiring fixed lengths UPC EAN will enforce length requirements for validation of the label Handheld will be required to transmit start and stop characters for Codabar and Code 39 labels Appropriate industrial length requirements will be enforced if con figured for valid...

Страница 364: ...xample R40101044123456789 RSS Expanded Prefix must be ASCII characters R4 Check character must be included in label UPC A Number system must be included in label data Check digit must be included in label data and is assumed to be cor rect Prefix must be an ASCII character A total length including prefix must be 13 Example A060992011187 UPC A with 2 Digit Supplemental Number system must be include...

Страница 365: ...el data and is assumed to be cor rect Supplemental data is appended to base label Prefix must be an ASCII character A total length including prefix must be greater or equal to 19 Code 128 Supplemental codes are variable length having a minimum of 2 data characters Characters immediately following base label must be of the form 8100 8101 or 8102 Example A0609920111878100000951 UPC E Number system m...

Страница 366: ...n label data and is assumed to be cor rect Prefix must be an ASCII character E total length including prefix must be 14 Example E0998875012345 UPC E with Code 128 Supplemental Number system must be included in label data Check digit must be included in label data and is assumed to be cor rect Supplemental data is appended to base label Prefix must be an ASCII character E total length including pre...

Страница 367: ...612 EAN 8 with 5 Digit Supplemental Check digit must be included in label data and is assumed to be cor rect Prefix must be an ASCII characters FF total length including pre fix must be 15 Example FF0021012612345 EAN 8 with Code 128 Supplemental Check digit must be included in label data and is assumed to be cor rect Supplemental data is appended to base label Prefix must be an ASCII characters FF...

Страница 368: ...12 EAN 13 with 5 Digit Supplemental Check digit must be included in label data and is assumed to be cor rect Prefix must be an ASCII character F total length including prefix must be 19 Example F110123456789112345 EAN 13 with Code 128 Supplemental Check digit must be included in label data and is assumed to be cor rect Supplemental data is appended to base label Prefix must be an ASCII character F...

Страница 369: ...e included in label data Label length including start stop and check characters and exclud ing prefix character must meet requirements imposed by the main scanner s fixed or variable label length control for this symbology type Start and stop characters must be included in label Prefix must be an ASCII character p Example p 123456789 I 2 of 5 Check character must be included in label data Label le...

Страница 370: ...ABCD and must be included in the label Example s 99 95s the lower case s at each end of the example is a placeholder for the start stop character set Code 128 Prefix must be an ASCII character Label length excluding prefix character must meet requirements imposed by the main scanner s fixed or variable label length control for this symbology type Function characters may be transmitted as a hexadec...

Страница 371: ... 144769254 Code 93 Prefix must be an ASCII character Label length excluding prefix character must meet requirements imposed by the main scanner s fixed or variable label length control for this symbology type Example Code93 test PDF417 Prefix must be an ASCII character P Label length excluding prefix character cannot exceed 300 charac ters In addition to this label length excluding prefix characte...

Страница 372: ...abel characteristics can be supported UPC A AIM does not specify UPC A as a separate symbology using this transmission format labels will be transmitted as EAN 13 Example E00060992011187 UPC E AIM does not specify UPC E as a separate symbology using this transmission format labels will be transmitted as EAN 13 Example E00000000998875 EAN 13 Check digit must be included in label data and is assumed...

Страница 373: ... to any EAN base label Prefix must be ASCII characters E2 Length of supplemental data including prefix must be 8 Total required length is 24 for EAN 13 and 19 for EAN 8 Examples addon portion is highlighted data is underlined UPC A 2 Digit addon E00060992011187 E112 UPC E 2 Digit addon E00000000998875 E112 EAN 8 2 Digit addon E400210126 E112 EAN 13 2 Digit addon E01101234567891 E112 UPC A 5 Digit ...

Страница 374: ...ncluding prefix is 13 Examples X01234567890 Code 39 Check character must be included in label data Label length including start stop and check characters and exclud ing prefix characters must meet requirements imposed by the main scanner s fixed or variable label length control for this symbology type Start and stop characters must be included in label Prefix must be ASCII characters A0 or A1 Exam...

Страница 375: ...he form ABCD ABCD and must be included in the label Example F0s 99 95s the lower case s at each end of the example is a placeholder for the start stop character set MSI Plessey Check character must be included in label data Label length including check character and excluding prefix charac ters must meet requirements imposed by the main scanner s fixed or variable label length control for this sym...

Страница 376: ...ast 1 character Maximum length is the maximum label size supported by the scan ner Example e001900123456789083103001750 I 2 of 5 Check character must be included in label data Label length including check characters and excluding prefix charac ters must meet requirements imposed by the main scanner s fixed or variable label length control for this symbology type Prefix must be an ASCII character I...

Страница 377: ...e it is identified as a Code 128 A prefix of C0 designates that no function code is present in the 1st or 2nd character position A prefix of C2 designates that a function code 1 is present in the 2nd character Example C0Code_128 Test PDF417 Prefix must be an ASCII characters L0 Label length excluding prefix character cannot exceed 300 charac ters In addition to this label length excluding prefix c...

Страница 378: ...F 16 Magellan 2200VS and 2300HS NOTES ...

Страница 379: ...Product Reference Guide F 17 NOTES ...

Страница 380: ...F 18 Magellan 2200VS and 2300HS NOTES ...

Страница 381: ...CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 ...

Страница 382: ...49 0 61 51 93 58 0 Fax 49 0 61 51 93 58 58 Italy PSC S p A Vimercate MI Italy Telephone 39 0 39 62903 1 Fax 39 0 39 6859496 Japan PSC Japan K K Shinagawa ku Tokyo Japan Telephone 81 0 3 3491 6761 Fax 81 0 3 3491 6656 Latin America PSC S A INC Miami Florida USA Telephone 305 539 0111 Fax 305 539 0206 United Kingdom PSC Bar Code Ltd Watford England Telephone 44 0 1923 809500 Fax 44 0 1923 809 505 PS...

Отзывы: