9. Warranty and Liability

1. PSA Products Pty Ltd (ABN: 99 076 468 703) of 17 Millicent Street, Burwood 3125 Victoria, 

Australia warrants this product for a period of five (5) years from the date of purchase, as 
reflected on the Authorised Reseller’s or Distributor’ invoice / receipt provided to you. PSA 
Products Pty Ltd will repair or replace the product (at the option of PSA Products) due to any 
manufacturing defect, at the cost of PSA Products Pty Ltd (excluding any labour costs relating to 
removal or re-installation of product, and transport costs).

2.  This warranty shall not apply to the product if it has been damaged, modified, abused or altered 

after the date of purchase, or if it fails to operate due to improper maintenance.

3.  To the extent permitted by law, the liability of PSA Products Pty Ltd arising from the sale or under 

the terms of this limited warranty shall not in any case exceed the cost of replacement and subject 
to this clause. In no case shall PSA Products Pty Ltd be liable for consequential loss or damages 
resulting from the failure of the product or breach of this, or: Any other warranty, express or 
implied, loss or damage caused by failure to abide by the instructions supplied in the leaflets.

4.  To the extent permitted by law, PSA Products Pty Ltd., makes no warranty, expressed or implied, 

written or oral, including that of merchantability or fitness for any particular purpose, with respect 
to the consumer replaceable battery if any. A product with non-serviceable built-in battery is 
covered under warranty of the product.

5.  This warranty is provided in addition to other rights and remedies you have under law: Our goods 

come with guarantees that cannot be excluded under the Australian Consumer Law. You are 
entitled to a replacement or refund for a major failure and compensation for any other reasonably 
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the 
goods. fail to be of acceptable quality and the failure does not amount to a major failure. What 
constitutes a major failure is set out in the Australian Consumer Law.

6  To make a claim under warranty, take the product (with a proof of purchase) to the store 

where you purchased the product or contact PSA Products Pty Ltd. Phone (03) 9888 9889. or  
Email: [email protected] with details, proof of purchase or expense claim in writing.

Содержание LIF6000WB

Страница 1: ...VER 6000 series Smoke Alarms You do NOT need a home wi fi system to use these units Multiple wireless units create their own independent wireless RF interlink network 1208 7208 00 Part No LIF6000WB RF...

Страница 2: ...te their own independent RF interlink alarm network This wireless baseplate is powered by the smoke alarm In the event of a mains power failure the backup battery of the smoke alarm will ensure the wi...

Страница 3: ...or To An Existing RF Interlink Network 6 2 3 Resetting The 6000WB 7 2 4 Connecting The 6000WB RF Baseplate to 6000DCW Wireless Smoke Alarms 8 3 Wireless FAQs 9 4 Installation Instruction 11 5 Operatio...

Страница 4: ...Operating Range 0 C to 45 C Humidity Operating range up to 95 RH non condensing Smoke Alarm Power 240VAC 50Hz 10mA max 4mA standby Radio Module Power 9VDC from smoke alarm Radio Frequency 918MHz Range...

Страница 5: ...er wireless units that connect to the Coordinator General Reset mode Resets a unit to Out of Box condition before it was first powered up 2 1 Setting Up an RF Interlink Network For easy first time set...

Страница 6: ...n Mode Red LED flashes three times every 2 seconds to indicate it is configured as a RFD in the network Join Mode will timeout in 15 minutes Step 3 After new unit s have joined press LINK button twice...

Страница 7: ...imeout Step 1 Press the LINK button twice on any existing 6000WB or 6000DCW unit The unit will enter Join Mode and flash its Red LED either 1 Twice every 2 seconds denotes Coordinator 2 Three times ev...

Страница 8: ...h one second ON and one second OFF After each unit has joined the network its Red LED will flash three times every 2 seconds to indicate it has been configured as a network RFD Join Mode will timeout...

Страница 9: ...Network not found The unit will then become a stand alone smoke alarm with no interlink 4 What happens if a Coordinator doesn t find any RFD to join after being set as Coordinator Coordinator times ou...

Страница 10: ...rk See Section 2 3 for details 11 Is there a way to get more informa tion about a trouble status In fault mode press LINK button for red LED error code Count the number of Red LED flashes and report t...

Страница 11: ...alarm auxilary device unless approved by PSA The earth terminal connection provided is for termination purposes only and is NOT electrically connected within the sealed alarm base units WARNING THIS...

Страница 12: ...and void the warranty Terminals on the back of base plate are marked and coloured as follows MARKINGS 9V 9VDC POSITIVE POWER SOURCE A ACTIVE SW SWITCH WIRE FOR INTERCONNECTION ONLY N NEUTRAL LOOP DEA...

Страница 13: ...WIRE THE SW TERMINAL OF TWO ALARMS WITH WIRELESS BASE TOGETHER NOTE Smoke alarms can be replaced without replacing the wireless base Active Active Active Neutral Household Cabling Neutral Neutral Swit...

Страница 14: ...t may take a few seconds for other interlinked units to alarm WARNING DO NOT USE AN OPEN FLAME TO TEST YOUR ALARM YOU COULD DAMAGE THE ALARM OR IGNITE COMBUSTIBLE MATERIALS AND START A FIRE ACCIDENTAL...

Страница 15: ...wiped with a damp cloth After cleaning reinstall your alarm and test your alarm by pressing the Test Button If cleaning does not restore the alarm to normal operation the alarm should be replaced WARN...

Страница 16: ...least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occup...

Страница 17: ...rms must be tested regularly to ensure the batteries and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarm...