5  seconds,  the  PD-4.7  deactivates  all  outputs. 
On  the  front  panel  display,  the  amperage  value 
will be displayed (blinking) and the Over-Current 
LED  (#3)  turns  red,  indicating  the  Over-Current 
status.

When  the  current  returns  to  a  normal  level,  the 
Director reverts to its normal operation. 

If  the  Power  Director  4.7  switches  off  for  this 
reason,  the  user  must  reactivate  it  manually 
by  pressing  the  Power  On  button.  If  the  Power 
Director  attempts  to  turn  the  power  on  and  the 
current  still  exceeds  the  preset  limit,  the  Power 
Director will turn off again.

To remedy the situation, you must either change 
the default setting to a higher value (not advised) 
or  remove  the  device  or  equipment  causing  the 
over-current problem (advised).
We advise you to leave the Over-Current value at 
or below the factory default setting. If you set the 
over-current value too high, the Power Director’s 
magnetic  circuit  breaker  may  activate  to  protect 
the unit, and you will have to manually reset the 
circuit breaker, located on the back panel near the 
AC input.

If  you  wish  to  change  the  over-current  value, 
press either Mode button and the amperage set-
ting  will  begin  to  blink.  Now,  the  Edit  Up/Down 
buttons  will  adjust  the  amperage  setting.  Press 
either  Mode  button  again  to  return  to  the  setup 
parameter selection.

Device  Number  for  PS  Bus  -  Setup 
Parameter 8

The  Power  Director  4.7  comes  with  a 
built  in  PS  bus.  The  PS  Bus  allows  all 
equipped  PS  Audio  gear  to  communicate 
with one another, and to communicate with 
an  optional  AMX  home  automation  serial 
interface  card  if  that  option  has  been  pur-
chased.

If more than one piece of PS Audio equip-
ment is used in a system, then each piece 
connected  to  the  bus  must  have  its  own 
identification number assigned to it. In this 
way,  each  piece  of  PS  Audio  equipment 

can  easily  be  recognized  and  identified  in  the 
system.

The  PS  bus  can  accommodate  individual  equip-
ment or groups of equipment. 

When you toggle the Mode buttons to this setup 
parameter, the display  will  read 8 _ _ 0, indicat-
ing you are in the eighth setup parameter and the 
Power Director is presently designated as “0”.

If you leave this default setting alone, the Power 
Director  will  operate  independently  of  any  other 
PS Audio equipment on the bus.

If  you  wish  to  assign  the  Power  Director  4.7  to 
operate  in  concert  with  other  PS  Audio  equip-
ment,  assign  it  a  number  from  “1”  through  “7”. 
This will allow up to seven Power Directors to be 
used in any one group.
To change the device number, press either Mode 
button and the device number will begin to blink. 
Now,  the  Edit  Up/Down  buttons  will  adjust  the 
device  number.  Press  either  Mode  button  again 
to return to the setup parameter selection.

Group Numbering - Setup Parameter 9

It  is  also  possible  to  assign  the  Power  Director 
to a group. There are three possible groups, and 
each group can have up to seven units within the 
group.

When you toggle the Mode buttons to this setup 
parameter, the display  will  read 9 _ _ 0, indicat-

7

Содержание Power Director 4.7

Страница 1: ...Trouble Shooting Guide 10 Warranty and Service 11 Notes 12 Contact Information What s in the Box One Power Director 4 7 One 6 foot AC power cord One user s manual One warranty card One spare 1 amp fa...

Страница 2: ...minum FRAME chassis Optional rack mount capability The PS Audio Power Director 4 7 is designed to operate as a stand alone power management tool or as a part of a larger power management system In mos...

Страница 3: ...after the front panel power button is activated We recommend that you set the switches so that your power amplifier turns on a few seconds after your preamplifier This should avoid any turn on thumps...

Страница 4: ...Voltage labeled Volts 2 Amperage labeled Amps 3 Wattage labeled Watts 4 Power Factor labeled PF 5 Setup Display Modes 6 Display blanking Voltage The default display mode indicates line voltage that i...

Страница 5: ...e adjustable values for each parameter The 11 setup parameters are 1 Zone 1 Delay 1 9 seconds 2 Zone 2 Delay 1 9 seconds 3 Zone 3 delay 1 9 seconds 4 Zone 4 Delay 1 9 seconds 5 Under Voltage Threshold...

Страница 6: ...ss either Mode but ton again to return to the setup parameter selec tion 6 Over Voltage Threshold The default display will read 6135 or 6270 depending on the voltage for your country This indicates yo...

Страница 7: ...PS bus The PS Bus allows all equipped PS Audio gear to communicate with one another and to communicate with an optional AMX home automation serial interface card if that option has been pur chased If...

Страница 8: ...e violated while the display is blanked the display will immediately activate again displaying the fault condition Front Panel Utility Service Outlet This outlet is fed directly from the input AC and...

Страница 9: ...wn are very remote This fuse is there to protect the Tranzorber surge protection circuitry from dam age Unplug the Power Director 4 7 from the wall outlet before removing the top cover If the fuse is...

Страница 10: ...quired be yond the capability of the importer PS Audio will fulfill the conditions of the warranty Such product must be returned at the owner s expense to the PS Audio factory Contact your PS Audio di...

Страница 11: ...Notes 11...

Страница 12: ...PS Audio International Inc 4824 Sterling Dr Boulder CO 80301 USA Toll Free 877 772 8340 Ph 720 406 8946 Fax 720 406 8946 www psaudio com...

Отзывы: