PS Audio PD 3.5 Скачать руководство пользователя страница 4

1. Power mode switches

The Power mode switches correspond to each 
of  the  Power  Zones. These  switches  are  used 
to control how the power zones respond to the 
front panel power button. They can be set in the 
following ways: 

• 

Always On 

[ON] - With the switch in the ON 

position, the zone will receive power as soon as 
the Power Director 3.5 is plugged into a power 
source.  Power  will  continue  to  pass  through 
this  zone  even  if  the  Director  is  switched  off 
(standby mode).  

• 

Switched 

[SW]  -  In  the  SW  position,  the 

zone will receive power as soon as the Power 
Director  is  switched  on  (operate  mode).  No 
power will pass to this zone when the Director 
is in standby mode.

• 

Delayed 

[DL] - In the DL position, the zone will 

activate three seconds after the Power Director 
is  in  operate  mode.  No  power  will  pass  to  this 
zone when the Director is in standby mode.

2. Circuit Breaker

In  the  event  that  the  connected  gear  draws 
more than 15 amps of current the circuit breaker 
will trip and no power will pass through any of 
the outlets. To reset the circuit breaker press the 
toggle switch.

3. IEC Power Input

15 Amp male IEC inlet.

4. DC Trigger (input)

The  Director  is  equipped  with  a  DC  input  trig-
ger. The DC trigger will control the power status 
of the Director.  See the DC Trigger section for 
more information.

5. Coaxial Pass Through

The  coaxial  pass  through  will  provide  surge 
protection  from  abnormal  voltage  situations 
on  CATV  or  satellite  lines.  The  coaxial  pass 
through  will  pass  the  full  bandwidth  of  HDTV 
signals.

6. Power Zone: Analog

The Analog Power Zone can be used to connect 
any  type  of  equipment.  For  best  results  prod-
ucts  such  as  preamplifiers,  phono  equipment, 
tuner or tape equipment should be grouped on 
the same Power Zone.

7. Power Zone: Digital/Video

The  Digital/Video  Power  Zone  can  be  used  to 
connect any type of equipment. For best results 
the  Digital/Video  Power  Zone  should  be  used 
to  connect  any  digital  equipment  and  display 
devices.  Products  such  as  DVD/CD  players, 
PVRs, Satellite or CATV tuners, Television sets 
or  front/rear  projectors  should  be  grouped  on 
the same Power Zone.

8. Power Zone: Amplifier

The Amplifier Power Zone can be used to con-
nect any type of equipment. For best results the 
Amplifier  Power  Zone  should  be  used  to  con-
nect any amplifiers or subwoofers.
 

Note:

The  names  regarding  the  Power  Zones  are 
simply  suggestions.  Each  zone  is  identical 
(except  the  number  of  outlets).  To  provide  the 
most  effective  isolation  follow  the  guidelines 
listed above.

For optimum performance, it is recommend that 
analog  equipment  be  grouped  separately  from 
digital  equipment.  Items  with  very  high  power 
consumption should use separate zones.

Rear Panel

4

Содержание PD 3.5

Страница 1: ...ng Guide 7 Warranty and Service 8 Contact Information What s in the Box One Power Director 3 5 One 6 foot AC power cord One logo trim tool One user s manual One warranty card IMPORTANT Be sure to save...

Страница 2: ...ivering superb AC perfor mance to your audio and video components The PS Audio Power Director 3 5 is designed to operate as a stand alone power management tool or as a part of a larger power managemen...

Страница 3: ...s to this zone when the Director is in standby mode Delayed DL In the DL position the zone will activate three seconds after the Power Director is in operate mode No power will pass to this zone when...

Страница 4: ...rector See the DC Trigger section for more information 5 Coaxial Pass Through The coaxial pass through will provide surge protection from abnormal voltage situations on CATV or satellite lines The coa...

Страница 5: ...d provide surge protection even if the director is in standby mode DC Trigger The DC input trigger mini jack 3 5 mm will con trol the power status of the Director Connect the Director to the product w...

Страница 6: ...ess that connector has at least 6 volts DC on it Remove the connector if necessary Specific Power Zones will not turn off If any power mode switch on the rear panel is set to ON then that specific zon...

Страница 7: ...ibutor from whom you purchased the product In the unlikely event of service required beyond the capability of the importer PS Audio will fulfill the conditions of the warranty Such product must be ret...

Страница 8: ...PS Audio International Inc 4826 Sterling Dr Boulder CO 80301 USA Toll Free 877 772 8340 Ph 720 406 8946 Fax 720 406 8967 www psaudio com...

Отзывы: