Prudent Way PWI-IV400 Скачать руководство пользователя страница 3

Prudent Way 400 Watt DC-AC Power Inverter User’s Manual 

Model: PWI-IV400 

 

 

- 2 - 

Thank you for choosing Prudent Way 400 Watt DC-AC Power Inverter.  Please take time 
to read the following manual before installing the Power Inverter.  Please note that failure 
to follow the proper procedures may result in personal injury or damage to the Power 
Inverter. 
 
We sincerely wish you find this quality Power Inverter provides you with many years of 
good service. 
 

1.

 

Safety and Warning 

 

Please read the following information carefully before using the Power Inverter. 

 

a

 

Warning – Shock Hazard 

o

 

DO NOT insert foreign objects into the Power Inverter AC receptacles. 

o

 

DO NOT expose the Power Inverter to water, rain, snow or spray.  Keep 
the Power Inverter dry at all times.  Do not use wet hands to touch this 
Power Inverter.   

o

 

DO NOT let the Power Inverter, its cord or other electronic devices get 
wet.  If you are operating the Power Inverter in a moving vehicle, please 
secure the Power Inverter to prevent it from shifting around.  Please note 
that any water damage will not be covered under warranty. 

 

a

 

Warning – Heated Surface 

o

 

DO keep all body parts and/or materials at least 1.5 inch away from the 
Power Inverter while in operation.  The Power Inverter may become 
uncomfortably hot during operating.  If the Power Inverter overheats, it 
will automatically shutdown. 

o

 

DO make sure the ventilation openings on the Power Inverter are not 
obstructed.  Ensure the Power Inverter is never covered and always allow 
for proper ventilation.   

o

 

DO avoid placing the Power Inverter near the vehicle’s heat vent or in 
direct sunlight.  Proper cooling is essential when operating the Power 
Inverter. 

 

a

 

Warning – Overload Situation 

o

 

DO know the wattage requirements of your electronic devices. Connect 
this Power Inverter to cigarette socket for loads under 150 watts.  For 
loads between 150 watts and 400 watts, connect this Power Inverter 
directly to a battery. Do not use this Power Inverter to charge any device 
with a higher wattage requirement than 400 watts.  Doing so will cause the 
Power Inverter shut down automatically and the red light will come on. 

 

a

 

Warning – Low Battery shutdown  

o

 

If the Power Inverter makes a beeping sound, turn off your device, unplug 
the Inverter, and restart the engine in your vehicle.  The beeping sound is 
the low-battery warning which indicates that the voltage of your vehicle 
battery is getting low. 

 

Содержание PWI-IV400

Страница 1: ...User s Manual Prudent Way 400 Watt DC AC Power Inverter PWI IV400 ...

Страница 2: ...ing 2 2 Contents 3 3 Connecting the Power Inverter for loads under 150 watts 3 4 Connecting the Power Inverter for loads over 150 watts and less than 400 5 5 Special Recommendations 6 6 Measuring the AC voltage 6 7 Common Problems and Simple Troubleshooting 6 8 Specifications 7 9 1 Year Limited Warranty 8 ...

Страница 3: ...urface o DO keep all body parts and or materials at least 1 5 inch away from the Power Inverter while in operation The Power Inverter may become uncomfortably hot during operating If the Power Inverter overheats it will automatically shutdown o DO make sure the ventilation openings on the Power Inverter are not obstructed Ensure the Power Inverter is never covered and always allow for proper venti...

Страница 4: ...y o Wrongfully plugging the AC power outlet LINE NEUTRAL will void the warranty o Use common sense to store this Power Inverter Do not place this Inverter near any batteries gasoline explosive vapors or other flammable and dangerous materials o Please disconnect all power sources should there be anything wrong with the Power Inverter operation 2 Contents PWI IV400 DC AC Power Inverter 400 watt Cab...

Страница 5: ...p This signifies the Power Inverter is operating properly and ready for use 6 Plug the AC device s into the two three prong receptacles and turn it on If you plug two devices at the same time make sure they consume 150 watts or less AC power together Picture 5 7 Turn off the Power Inverter prior to disconnect the power source Picture 1 Picture 2 Picture 3 Picture 4 Picture 5 ...

Страница 6: ...ke sure to connect to the right terminals with red to red and black to black Tighten the screws on the DC input terminals Picture 3 above 4 Fasten the red positive clip to the positive battery post and then fasten the black negative clip to the negative battery post Please wear protective eyewear and clothing when you use the Power Inverter or work with the batteries Do not contact the battery ter...

Страница 7: ... Be sure to disconnect the Power Inverter prior to use a battery charger to charge your battery Failure to disconnect the Power Inverter first will lead to an input surge which will damage the Power Inverter 3 Use only the cable included to connect the Power Inverter and the battery Any source of extension such as adding extension cord will result in a reduction of efficiency and output and may hu...

Страница 8: ...eriod of time Simply reduce your load and allow the Power Inverter to cool down 7 Alarm is beeping Ö Alarm will be on when battery is low or the Power Inverter is over heat over temperature Please recharge battery or turn off the Power Inverter to cool down Always keep the Power Inverter away from heated sources and keep the ventilation openings in good condition 8 Red light is on Ö Red light indi...

Страница 9: ...ciency or suitability of any technical or other information provided in the user manual or other documentation provided with the product Prudent Way assumes no responsibility or liability for losses damages costs or expenses whether special direct indirect consequential or incidental which might arise out of or related to the use of such information The use of any such information will be entirely...

Страница 10: ...Prudent Way 400 Watt DC AC Power Inverter User s Manual Model PWI IV400 9 For support or general inquiry please contact Prudent Way Inc Toll Free 866 384 3873 Email Support prudentway com ...

Отзывы: