INTRODUCTION TO OZONE

  

 

Ozone (O

3

) is generated by irradiating air or oxygen (O

2

) with ultraviolet radiation. Ozone is a molecule of oxygen that is formed 

when three atoms of oxygen are bound together instead of the normal two atoms. The extra oxygen atom makes ozone the most 
powerful oxidizer and sanitizer readily available.  

Since ozone is unstable and quickly decomposes to normal oxygen under normal conditions, it cannot be shipped or stored. 
Therefore, it must be manufactured on site for immediate use. In normal air it lasts about an hour. In normal pool water it lasts just 
long enough to purify the water - less than 1 second. 

Although ozone is mainly thought of as a sanitizer, it acts primarily as an oxidizer in the pool environment. In a typical pool run on 
chlorine only, up to 90 percent of the chlorine may be used up in reactions unrelated to disinfection. The byproducts of these 
reactions are combined chlorines. Combined chlorines are the cause of eye irritation, odor, and the other unpleasant side effects of 
chlorination. 

When ozone is used, it oxidizes a large portion of the contaminants (usually referred to as bather load) which result in the formation 
of combined chlorines. The result is that more chlorine is available for disinfection and less chlorine is required to maintain the pool. 
Ozone also provides some disinfection, but an ozone residual cannot be established, so the use of chlorine or bromine is always 
recommended. 

PREPARING FOR INSTALLATION 

 

1.  Locate Model PZ2-1 or PZ2-2 Ozonators or the compressor unit for PZ2-4 and higher models so that dust, sand, debris, 

chemicals, or other foreign objects are not sucked into the compressor's intake fan or hose (if equipped with Noise 
Attenuator).  

2.  Check electrical system: 240VAC double switched per N.E.C. standards; 120VAC single switched.  
3.  Check for and correct all plumbing for leaks.  
4.  Check for Suction Line Check Valve. Equipment may draw if no check valve is present.  
5.  Balance the pH.  
6.  Backwash the filter.  
7.  Shock the pool with a non-lithium-based material. The use of Calcium Hypochlorite or Sodium Hypochlorite is 

recommended.  

NOTE: If the pool has a Diatomaceous Earth (DE) filter, a 3/4" ball valve must be installed between the pump and the input side of 
the Venturi Injector. 

INSTALLATION 

 

NOTE: 

The instructions in this document provide general installation guides. Consult your dealer for specific installation instructions. 

Additional information is available at www.prozoneint.com. Check system for any visible shipping damage. If damage has occurred, 
contact the delivery company and your dealer immediately. Before beginning installation, please turn to the Installation Kit Inventory 
Section and verify that all listed parts are on hand.  
 

Tools Needed

: Cordless Power Drill, Screw Driver, Adjustable Wrench, Pliers, Wall Mount Screw Anchors, Knife  

 

 

 

 

 

 

 

 

Содержание PZ2 Series

Страница 1: ...level to prevent water from contacting electrical equipment Install to provide drainage of compartment for electrical components 9 A pressure wire connector is provided in the control box inside the u...

Страница 2: ...e also provides some disinfection but an ozone residual cannot be established so the use of chlorine or bromine is always recommended PREPARING FOR INSTALLATION 1 Locate Model PZ2 1 or PZ2 2 Ozonators...

Страница 3: ...solenoid control valve may be necessary 13 Attach one end of the remaining length of 1 4 inch hose to the ozone generator and the other end to the inlet side of the check valve Making sure flow is awa...

Страница 4: ...lamp 4 Insert venturi injector into the other end of the 6 inch length of 1 inch hose making sure flow is away from the saddle and secure with a clamp Flow is marked on side of injector with an arrow...

Страница 5: ...cal Installation System is 120 or 240 VAC 50 60 HZ Wire Prozone ozone generator system to circulation pump switch or timer Prozone system and circulation pump should be started simultaneously Use N E...

Страница 6: ...re Verify check valve in venturi is operating properly Cloudy water foamy water scum Water chemistry out of balance Total Dissolved Solids TDS level too high Filter not working Check readings and bala...

Страница 7: ...itting 1 inch FPT x 1 inch HB 2 each Hose Polybraid 3 8 inch 20 feet 6m Hose Clear Vinyl 1 inch 10 feet 3 05m Compressor 1 each Valve Check inch 1 each Clamp Hose Metal 1 5 inch 4 each Clamp Plastic B...