OPERATION

TROUBLESHOOTING GUIDE

 

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

 

Loose wiring 

Check all wiring connections 

No power to unit 

Check voltage compatibility 

Check power source 

No light from Prozone unit(s)

 

Defective lamp or other internal component 

Return unit to dealer 

Excessive back pressure 

Check for kinks or clogs in hose or plumbing 

Leak in fitting 

Replace fitting 

No bubbles from injector or 

no evidence of ozone in pool 

Filter not working 

Check filter 

Water in Ozone Generator 

Check Valve failure 

Verify Check Valve is operating properly

 

Water chemistry out of balance 

Check readings and balance accordingly 

Total Dissolved Solids (TDS) level too high 

Refer to dealer for proper water testing 

Cloudy water; foamy water; scum 

Filter not working 

Clean or replace filter 

NOTE: Cloudy water may occur when the ozone generator is started. Filter and backwash as necessary. 

Turn on PZ2-12 Boost Pump, (top breaker), and allow water to fill the PZ2-12 plumbing and begin to flow completely through the system.

Close the Ball Valve, in between the Venturi Injector(s), by rotating it clockwise fully and allow the system fo run for a minute or two

to stabilize.

Turn on PZ2-12 Ozone Generator, (bottom breaker).

Verify compressor and compressor fan are both running.

Open Ball Valve half-way by rotating it counter-clockwise until it points to approximately the one O’clock position.

1.

2.

3.

4.

5.