background image

 

Wiring Diagrams and Steps 

Connect to Door Hardware 

 

Step 1: 

Connect the 5 wires from the Edge Reader Enclosure (outside) 
unit to the 5 wires from the Edge Relay Enclosure (inside) unit 
based on corresponding colors 

Step 2: 

Crimp the positive (red) wire from the power source to the red 
wire of the Edge Relay Enclosure (inside) unit ​

and​

 to one of the 

wires from the strike 

Step 3: 

Crimp the ground (black) wire from the power source to the 
black wire of the Edge Relay Enclosure (inside) unit ​

and​

 to the 

white wire of the Edge Relay Enclosure (inside)  

Step 4: 

Crimp the green wire from the Edge Relay Enclosure (inside) unit 
to the remaining strike wire 

 

 
 
 
 
 
 
 
 
 
 

|

  

15 

User Manual and Installation Guide: Proxy Mobile Reader Edge 

 

This document may have been updated since printing — for the latest, please visit ​https://proxy.com/s/edge-install

 

Содержание Mobile Reader Edge

Страница 1: ...User Manual and Installation Guide Proxy Mobile Reader Edge www proxy com support proxy com Last updated February 10 2020...

Страница 2: ...2 User Manual and Installation Guide Proxy Mobile Reader Edge This document may have been updated since printing for the latest please visit https proxy com s edge install...

Страница 3: ...for Edge Reader Enclosure 5 Core Grey 10 Cable colors for Edge Relay Enclosure 5 Core Grey 10 Cable colors for Edge Relay Enclosure 8 Core Black 11 Wiring Recommendations 12 Mounting the Edge Reader...

Страница 4: ...4 User Manual and Installation Guide Proxy Mobile Reader Edge This document may have been updated since printing for the latest please visit https proxy com s edge install...

Страница 5: ...unctionality Proxy Mobile Reader Edge is a standalone physical access control wireless mobile credential reader that provides contactless credentials over Bluetooth Low Energy BLE The Edge Reader inte...

Страница 6: ...r Enclosure Wall Plate Dimension in millimeters mm inches in 6 User Manual and Installation Guide Proxy Mobile Reader Edge This document may have been updated since printing for the latest please visi...

Страница 7: ...Enclosure Wall Plate Dimensions in millimeters mm inches in 7 User Manual and Installation Guide Proxy Mobile Reader Edge This document may have been updated since printing for the latest please visit...

Страница 8: ...nication Protocol BLE IEEE 802 11b g n Credential Type Proxy Mobile Credential Credential Transmission Technology BLE 2 4GHz Dimensions Edge Reader 128 3 mm x 44 7 mm x 24 6 mm H x L x W Dimensions Ed...

Страница 9: ...Screws A 6 32 x 1 Phillips x4 Security Screw B 6 32 x 3 8 Tamper Resistant x2 Nylon anchor plugs 6 x 1 x4 Recommended Tools Wire Stripper s 18 24 AWG Screwdrivers Tamper resistant torx bit TR10 Wire c...

Страница 10: ...alled at a distance greater than 30 ft 10 m from each other Wiring Harness Information Cable colors for Edge Reader Enclosure 5 Core Grey Name Colors Colors Sheath Color UART TX Green UART RX White 5V...

Страница 11: ...differ between electronic strike manufacturers and applications All wires not being used should be terminated Refer to the online documentation for operation of DPS and DPS Caution During wiring make...

Страница 12: ...ble below Type Alpha Wire P N or Equivalent AWG Shielded Max Length Power 22 AWG 1292C 22 Yes 600 ft 180 m Power 18 AWG 2422C 18 Yes 1500 ft 455 m Reader 22 AWG 1299 10C 22 Yes 250 ft 75 m Reader 20 A...

Страница 13: ...e Reader Location of mounting holes on wall 13 User Manual and Installation Guide Proxy Mobile Reader Edge This document may have been updated since printing for the latest please visit https proxy co...

Страница 14: ...gs into the wall Connect the wires as per Wiring Harness Information o Cables with the grey sheath 5 Core Grey are to be connected color to color Edge Reader and Edge Relay enclosure wall plates are t...

Страница 15: ...losure inside unit and to one of the wires from the strike Step 3 Crimp the ground black wire from the power source to the black wire of the Edge Relay Enclosure inside unit and to the white wire of t...

Страница 16: ...ontroller Step 3 Connect the black GND and red VDC wires to a power source this could be provided by the controller equivalent to what is needed to power the electrified lock Door Contacts The DPS and...

Страница 17: ...is programmed with the pre defined RF parameters Each product RF power level is measured to ensure the power level not exceeding the target power level in a fully calibrated setup The user has no pos...

Страница 18: ...e the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the...

Страница 19: ...Exposure Information This device has been tested and meets applicable limits for Radio Frequency RF exposure This equipment should be installed and operated with a minimum distance of 20 cm between th...

Страница 20: ...ease scan the barcode on the label to view the user guide Waste Electrical and Electronic Equipment WEEE This symbol means that according to local laws and regulations your product and or its battery...

Страница 21: ...ng enough voltage Either wiring at the reader or at the power supply has been disconnected Double check both connections to bring the reader back online Lack of power to the ACS system may also cause...

Страница 22: ...th is enabled If it is toggle airplane mode to disconnect all existing Bluetooth connections reconnect it for a strong connection Reader flashes red Do not have permission to access that reader Ensure...