User Manual
Page 9
Version 05
•
Clean panels and frame parts regularly with lukewarm water and a microfibre cloth. Use no solvents,
chloride, polish, chemical cleaning products or wax polishes. Use only disinfectants approved by the
manufacturer for the disinfection of the padding.
•
As far as are present, the locking pins and set screws should also be greased.
•
In order for the machine to remain technically sound any parts damaged due to wear and tear should be
immediately replaced with original parts and the machine should not be used until it is repaired.
•
A technical safety inspection should be performed every 12 months.
•
If the machine is equipped with the isometric power option a technical measurement inspection should be
performed every 24 months.
Note:
If you do however fine some unexpected damage stop the training immediately. If there is a
problem, which you cannot easily solve then contact the proxomed
®
Service. The authorised
Service will provide you with quick and competent help or give you instructions on how to
do this. At the end of the Medical Product Book, you will find the form "Repair Order / Fault
Reporting". This template is to copy, fill out, and fax. Please fill out this form with the
information you have and describe the fault as accurately as you can.
10
Prepare the product for use
10.1
Transport
The machines are normally delivered completely assembled by our employees or by a freight company.
10.2
Storage
The storage location of the machine should be dry, free from seawater and dust-proof, with a storage temperature
b5 °C to 45C. Protect the machine from bumps, scratches, and moisture. Remove any transport safety
devices only after the machine is positioned in its final location. Incorrect storage, also at the operating location
leads to the loss of the machine warranty.
10.3
Installation
The machine must be horizontal, on a flat, stable, and impact-resistant surface that can withstand the weight of the
machine as well as the maximum allowable weight of a person, altogether 180 kg. If the surface is uneven then
even-out using suitable material (e.g. high-strength plastic) to achieve a level surface. In this case, it is important to
make sure that the material used to even-out the surface cannot rust.
Avoid harsh, abrupt putting down of the machine. An important prerequisite for the proper functioning of the
machine is the orientation with a spirit level. The machine is usable when free-standing.
Avoid positioning the machine in busy areas such as near doors and passageways.
10.3.1
Protective Cover
The covers of the tergumed
®
machines consists of high-quality frosted glass, designed as safety glass. The training
machine only meets the legal requirements for use in training with the protective cover on.
The protective covers affixed by the manufacturer must not be removed or altered; as otherwise, the standards for
training are not met.
10.4
Before use check
Check prior to using, the proper condition of the following components:
-
Flat belts for visible damage, particularly the respective end mount.
-
Locking pins for correct functioning, the detent knob must engage on its own.
-
Stability of the machine at the place of use.
-
Undamaged protective cover.
-
Fixed screw connections.
-
Smooth movement guiding.
-
Firm hold of the insertion pin.
-
Secure locking of the pneumatic compression spring to the position settings.