User’s Guide • 3–3
Chapter 3 • Using the Desktop Projector
• Check the filter element. Clean or replace it if necessary. For
more information, please refer to
Chapter 4, Maintenance
.
• Check the rear exhaust vent. If the projector has reached an
overtemperature condition and the fan is working, you
should feel a strong rush of hot air from the vent. If the fan
is not working, the projector needs service.
After the projector returns to its normal operating temperature,
the TEMP indicator will go out. To turn the lamp back on, first
turn the power switch off and on again, then press the
STANDBY/ON key on the Control panel.
Note:
The remote’s STANDBY/ON key won’t work after an
overtemperature condition until the power ON/OFF switch is
cycled and the lamp is turned on from the Control panel.
LAMP Indicator
The LAMP indicator is a two-function display.
• The LAMP indicator blinks red if the air filter is detached.
• The LAMP indicator blinks red if the lamp is defective.
ON Indicator
The ON indicator is a four-function display.
• It glows orange in Standby Mode.
• It blinks green during lamp start-up.
• It glows green during projector operation.
• It blinks orange during lamp cool-down.