USB and eSATA to SATA II RAID Subsystem
Installation and Configuration Manual
70
3.10.3 Hardware Monitor
To view the RAID subsystem’s controller hardware information, click the
Hardware Monitor
link from
the
Information
menu. The Hardware Monitor Information screen appears.
NOTE: When no disk drive is installed in the disk slot, the disk
temperature will show “--”. The disk temperature will also show “--
” when “HDD SMART Status Polling” is disabled in System
Configuration.
The Hardware Monitor Information provides the temperature and voltage levels of the RAID subsystem.
All items are also unchangeable. When the threshold values are exceeded, warning messages will be
indicated through the LCD, LED and alarm buzzer.
Item
Warning Condition
Controller Board Temperature
> 60 Celsius
HDD Temperature
> 60 Celsius
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR Supply V2.5V
< 2.25V or > 2.75V
CPU Core V1.3V
< 1.17V or > 1.43V
DDR Termination Power +1.25V
< 1.125V or > 1.375V