Proview AY965 Скачать руководство пользователя страница 3

                                                  

 

 

WARNING

 

 

To prevent from fire or shock hazard,do not

 

expose monitor to  any rain or any form of water.High voltage is 

inside the monitor so please do not remove the back cover of the cabinet if you are not a qualified 
monitor engineer.Contact the local dealer or the nearest 

Proview

 branch office if you need help. 

 

 

A.

 

IMPORTANT SAFETY INSTRUCTION 

 

Prior to using this service manual,please ensure that you have carefully followed all the procedures  outlined in 
the user's manual for this product. 

1.

  Read all of  these instructions. 

2.

  Save these instructions. 

3.

  Follow all warnings and instructions a marked on the product. 

4.

  Unplug this product from the wall outlet before cleaning.Do not use liquid cleaners or aerosol 

     cleaners, use a damp cloth for cleaning. 

5.

  Do not use this product near water. 

6.

  Do not place this product on an unstable cart,stand or tablle.The product may fall,causing serious 

     damage to the product. 

7.

  Slots and openings in the cabinet and the back or bottom are provided for ventilation,to ensure 

     reliable operation of the product and to protect it from overheating,those openings must not be 
     blocked or covered.The openings should never be blocked by placing the product on a bed,sofa, rug, 
     or other similar surface.This product should not be placed in a built-in installation less proper  
     ventilation is provided.  

8.

  This products should be operated from the type of power source indicated on the marketin label. 

     If you are not sure of the type of power available, consult your dealer or local power company  

9.

  This product is equipped with a 3-wire grounding type plug,a plug having a third (grounding) 

      pin.This plug will only fit into a grounding-type power outlet.This is a safety feature,if you are 
      unable to insert the plug into the outlet,contact your electrician to replace your obsolete outlet.Do 
      not defeat the purpose of the grounding-type plug. 

10. 

Do not allow anything to rest on the power cord.Do not locate this product where persons will walk 

       on the cord. 

11.

 If an extension cord is used with this product,make sure that the total of the ampere ratings on the 

      product plugged into the extension cord to the waplugged into outlet does not exceed 15 ampere. 

12. 

Never push objects of any kind into this product through cabinet slots as they may touch dangerous 

      voltage points or short out parts that could result in a risk of fire or electric shock.Never spill liquid 
      of any kind on the product. 

13.

 Do not attempt to service this product yourself,as opening or removing covers may expose you to 

      dangerous voltage points or other risks.Refer all servicing to service personnel. 

14.

 Unplug this product from the wall outlet and refer servicing to qualified service personnel under the 

      following conditions. 

a.

 

When the power cord or plug is damaged or frayed. 

b.

 

If liquid has been spilled into the product. 

c.

 

If the product has been exposed to rain or water. 

d.

 

If the product does not operate normally,when the operating instructions are followed.Adjust 

    only those controls that are covered by the operating instructions since improper adjustment of  
    other controls may result in damage and will often require extension work by a qualified 
   technician to restore the product to normal operation. 

e.

 

If the product has been dropped or the cabinet has been damaged. 

f.

 

If the product exhibits a distinct change in performance,indicating a need for service.

 

Содержание AY965

Страница 1: ...965 Service Manual...

Страница 2: ...1 A IMPORTANT SAFETY INSTRUCTION 1 B SPECIFICATIONS 2 C TIMING CHART 3 D CONTROL LOCATION 5 E CONDUCTION VIEW 6 F ADJUSTMENT PROCEDURE 8 G TROUBLE SHOOTING HINTS 9 H REPLACEMENT PARTS LIST 13 I BLOCK...

Страница 3: ...a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature if you are unable to insert the plug into the outlet contact your electrician to...

Страница 4: ...zontal Vertical 85 85 Degrees 85 85 Degrees 13 Power Source 100 240 Vac 60 50 Hz 14 Power Consumption max 60W 15 Connection Type 15 Pin D Type 16 Input Signal Video Sync Analog R G B 0 7Vp p 75 Ohms T...

Страница 5: ...6 349 6 222 6 400 4 800 Front Porch s 0 635 0 636 0 762 0 508 0 667 1 000 1 120 H Sync width s 3 813 3 813 1 270 2 032 2 000 3 200 2 400 H Back Porch s 1 906 1 907 4 063 3 810 3 556 2 200 1 280 V Fre...

Страница 6: ...0 369 0 320 0 203 0 444 0 119 H Sync width s 1 616 2 092 1 813 1 219 1 037 1 067 H Back Porch s 3 232 2 462 1 920 2 235 2 296 1 837 V Frequency Hz 75 0 60 0 70 1 75 0 60 0 75 0 V Total ms 13 333 16 66...

Страница 7: ...1 Menu Button 4 Power Button 2 Select Button 5 LED Power Display 3 Auto Button Rear panel 1 VGA Signal Cable 2 Power jack 3 Line in jack...

Страница 8: ...E CONDUCTION VIEW MAIN BOARD Component Side...

Страница 9: ...MAIN BOARD Solid Side...

Страница 10: ...1 Hold key then turn the power switch of the monitor OFF 2 Hold key then turn the power switch of the monitor ON 3 You can into factory adjustment mode D Auto mode Check PC or Pattern generator Crossh...

Страница 11: ...ack LED ON Push the power ON OFF switch LED Color change Check main board U10 Pin141 Hi Lo under push power sw Back light ON To Step 2 Make sure the connection of Inverter is fine 12V Check the CN1 Pi...

Страница 12: ...NO YES YES NO YES NO B Hi Lo under push power sw Change the Inverter Display Nice Job To Step 2 A Check the connection of CN8 cable Display Nice Job Change the main board Change the main board...

Страница 13: ...YES YES YES NO NO YES Step 2 Check the main board 12V 5 0 V Check U13 U14 R65 H V input Signal Check the main board U10 Pin 146 Change U11 Check H V Signal Display Nice Job Change Signal Cable Check F...

Страница 14: ...YES NO NO YES No display White Check the main board 5V 3 3V H V Input Signal Check the main board U11 Pin14 Change U11 Check H V Signal Display Nice Job Change Signal Cable Check U13 U14 Check U1 U13...

Страница 15: ...Audio 1 20 002 G01 0567 A Warranty card 1 21 846 120 E0AL A Adapter 60W 12V 5A 1 22 631 003 A011 2C 3 5 Audio Cable 180cm 1 23 153 001 TCO99 All Series TCO99 Label for Panel 1 24 170 005 LCD7 LCD PE B...

Страница 16: ...62 506 0CS 5828 LVD 8bit 56pin TSSOP 2 63 506 2AI C1578 IC DC TO DC IC AIC1578 SMD 1 64 506 524 LC21 Memory IC 24LC21 SMD 1 65 506 5NM 24C16 24C16 SO8 Memory IC SMD 1 66 506 774 LCX14 74LCX SOIC14 HI...

Страница 17: ...udio 1 106121 005 AY765 A Audio Brackey 1 107123 005 AY765 Shield Cover T 0 3mm 1 108100 006 3062 Screw R3 6mm TP ISO 6 109100 008 3012 Screw R3 8mm TP1 2 110 107 008 3032 B M3xL8 4 111 107 008 3073 B...

Страница 18: ...W20mm 2 152131 030 2120 D sub screw 2 153506 1SM 89516 SYNCMOS SM89516C25J 44Pin PLCC 1 154631 006 7013C SIRE HARDNESS 6PIN 2 0 190mm Core 1 155631 006 7014 T AY865 100mm 2 0 24AWG 1 156631 008 G005 W...

Страница 19: ...470 16275 EC 47uF 16V Elec radial 5 7 3 177330 471 16205 E CAP 470UF 16V 20 105C 9 178504 000 MCP101 Reset IC MCP101 450HI TO TO92 1 179504 A00 8227 Audio AMT IC TA8227P UTC 1 180520 007 L431 Diode T...

Страница 20: ......

Страница 21: ...SDA SCL POWER ADAPTER 12V SWITCH POWER SUPPLY AND 3V 5V 12V C O N N E N T VGA IN 12PIN D D C 24C21 EEPROM ADC SCALER LVDS LVDS MCU 24C16 EEPROM INVERTER 12V C O N N E N T FUNCTION KEY 8PIN LCD PANEL L...

Страница 22: ...VCLK VCC L23 100 R70A 0 L15 0 C125 0 1u CN8 D SUB15PIN 90 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 16 RED GREEN BLUE NC GND GND GND GND VCC GND NC MID1 HSYNC VSYNC MID3 GND GND C124 0 1u R83 75 R71A 0...

Страница 23: ...9 148 147 146 145 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121 16 CAP_HREF AGNDP CAP_HSYNC AVDDP CAP_VSYNC AVDDC BLU_INB_0 RXCN BLU_INB_1 RXCP BLU_IN...

Страница 24: ...P3 5 P1 0 T2 P1 1 T2EX P1 2 P1 3 P1 4 P1 5 P1 6 P1 7 AD0 P0 0 AD1 P0 1 AD2 P0 2 AD3 P0 3 AD4 P0 4 AD5 P0 5 AD6 P0 6 AD7 P0 7 A8 P2 0 A9 P2 1 A10 P2 2 A11 P2 3 A12 P2 4 A13 P2 5 A14 P2 6 A15 P2 7 P3 7...

Страница 25: ...4 1 8 2 7 3 6 4 5 RP7 33X4 1 8 2 7 3 6 4 5 RP13 33X4 1 8 2 7 3 6 4 5 RP9 33X4 1 8 2 7 3 6 4 5 RP15 33X4 1 8 2 7 3 6 4 5 RP16 33X4 1 8 2 7 3 6 4 5 R64 33 R62 33 R37 0R C33 NP L4 BE0603 CON3 FTC W30P 1...

Страница 26: ...TC3 100uF 16V TL2 HCB4532K 800T60 C23 0 1u C91 300p TU4 UTC7809 2 1 3 G I O C15 0 1u R63 2K_1 R65 6 2K_1 TC5 10uF 25V U2 ICBE TO92 2 3 1 G O I C1 0 1u BE0805 L30 TC1 22uF 16V TC15 100uF 16V TC4 10uF 1...

Страница 27: ...u C122 220p C111 0 1u C112 0 1u TC22 470uF 16V TC30 100uF 16V R74 R1206 100 D6 ZD9 1V 2 1 CN6 BASE2 1 2 CN5 BASE2 1 2 L29 0 0805 TC10 470uF 16V TC12 470uF 16V TC23 22uF 16V D7 1N4148 1 2 R72 330 TC28...

Страница 28: ...Memu...

Отзывы: