ProtoNode RER and ProtoNode LER 

Startup Guide  

For Interfacing Customer Product: Harsco Industrial Patterson-Kelley 

ENVI Control Systems and Love Controller 

To Building Automation Systems: BACnet MS/TP, BACnet IP, Metasys 

N2, Modbus TCP, and LonWorks 

APPLICABILITY & EFFECTIVITY

 

Explains the ProtoNode RER and LER hardware and how to install it.   

The instructions are effective for the above 

as of March 2013 

Содержание ProtoNode LER

Страница 1: ...ustrial Patterson Kelley ENVI Control Systems and Love Controller To Building Automation Systems BACnet MS TP BACnet IP Metasys N2 Modbus TCP and LonWorks APPLICABILITY EFFECTIVITY Explains the ProtoN...

Страница 2: ...toNode Startup Guide Page 2 of 38 ProtoCessor 1991 Tarob Court Milpitas California 95035 USA Web www protocessor com Tel 408 964 4444 Fax 408 964 4425 Toll Free 800 317 8319 email support protocessor...

Страница 3: ...d Protocol 14 3 4 Wiring the ProtoNode LER Field Port to a LonWorks network 15 3 5 Power Up the ProtoNode RER or LER 15 4 Commissioning the ProtoNode LER on a LonWorks network 16 4 1 Commissioning the...

Страница 4: ...5 bottom 10 Figure 5 Pin outs for the ENVI s Modbus RS 485 port and power to the ProtoNode 11 Figure 6 Pin outs for the Love s Modbus RS 485 port and power to the ProtoNode 11 Figure 7 Wiring diagram...

Страница 5: ...AE 2 Metasys is a registered trademark of Johnson Controls Inc 3 4 LonWorks is a registered trademark of Echelon Corporation The BTL Mark on the ProtoNode RER is a symbol that indicates to everyone th...

Страница 6: ...85 interface located on the ProtoNode s 6 pin connector See Section 3 6 Power up the ProtoNode RER and LER See Section 3 6 7 Commission the ProtoNode on the LonWorks Network This needs to be done by t...

Страница 7: ...s B0 B3 can be used to set the serial baud rate to match the baud rate provided by the Building Management System for BACnet MS TP Metasys N2 is always defaulted to 9600 baud and the B bank is disable...

Страница 8: ...BACnet IP BACnet MS TP 2 ENVI On Off Off Off BACnet IP BACnet MS TP 3 ENVI Off On Off Off BACnet IP BACnet MS TP 4 ENVI On On Off Off BACnet IP BACnet MS TP 5 ENVI Off Off On Off BACnet IP BACnet MS...

Страница 9: ...es Profile S0 S1 S2 S3 LonWorks 1 ENVI Off Off Off Off LonWorks 2 ENVI On Off Off Off LonWorks 3 ENVI Off On Off Off LonWorks 4 ENVI On On Off Off LonWorks 5 ENVI Off Off On Off LonWorks 6 ENVI On Off...

Страница 10: ...ornia 95035 USA Web www protocessor com Tel 408 964 4444 Fax 408 964 4425 Toll Free 800 317 8319 email support protocessor com 3 INTERFACING THE PROTONODE TO ENVI AND LOVE CONTROLLER 3 1 ProtoNode RER...

Страница 11: ...4 4425 Toll Free 800 317 8319 email support protocessor com 3 2 Wiring Connections to ProtoNode RER and LER for the ENVI and Love Controller ProtoNode 6 Pin Phoenix connector Pin outs to ENVI s and Lo...

Страница 12: ...o not connect Ground between ENVI and the ProtoNode s RS485 Ground Figure 7 Wiring diagram for the EVNI s Modbus RTU RS 485 to the ProtoNode s RS 485 port 3 2 2 Biasing the Modbus RS 485 Network An RS...

Страница 13: ...the RS 485 trunk must be properly terminated at each end If the ProtoNode is placed at one of the ends of the trunk you turn the Blue RS 485 End of Line Terminating switch to ON position On short cab...

Страница 14: ...2 networks Connect BACnet MS TP or N2 RS485 to the 3 pin RS485 connector on ProtoNode RER as shown below Figure 10 Connection from ProtoNode to RS 485 BMS Field Protocol BACnet MS TP or Metasys N2 See...

Страница 15: ...otoNode to the field network with the LonWorks terminal using a twisted pair non shielded cable LonWorks has no polarity Figure 12 ProtoNode LER LonWorks FFT 10 2 wire screw terminal 3 5 Power Up the...

Страница 16: ...enclosure to access the Service Pin See the illustration on the ProtoNode LER as to which way to toggle the screw driver during commissioning If an XIF file is required see steps Section 4 4 1 to gene...

Страница 17: ...4444 Fax 408 964 4425 Toll Free 800 317 8319 email support protocessor com For Windows XP and Windows 7 select Use the following IP address Click twice Open a web browser and go to the following addr...

Страница 18: ...Connect the PC to the ProtoNode via the Ethernet port Figure 15 Ethernet port location of ProtoNode Connect a standard CAT5 Ethernet cable straight through or cross between the PC and ProtoNode The D...

Страница 19: ...s TCP via GUI Open a PC web browser enter the default IP address of the ProtoNode 192 168 1 24 and connect to the ProtoNode From the GUI main home page click on setup and then Network Settings to ente...

Страница 20: ...tartup Guide Page 20 of 38 ProtoCessor 1991 Tarob Court Milpitas California 95035 USA Web www protocessor com Tel 408 964 4444 Fax 408 964 4425 Toll Free 800 317 8319 email support protocessor com Fig...

Страница 21: ...ve the BMS Integrator on site A Serial or USB to RS 485 converter is needed to test BACnet MS TP 6 1 Downloading Chipkin Automation s CAS Explorer and Requesting an Activation Key To request a 2 week...

Страница 22: ...P and BACnet Ethernet boxes o Set the BACnet MSTP MAC address to 0 o Set the BACnet MSTP Baud Rate to 38400 o Click Ok o On the bottom right hand corner make sure that the BACnet MSTP box is green o C...

Страница 23: ...correct baud rate and device instance o Verify IP address setting o Verify wiring If the problem still exists a log needs to be taken and sent to FieldServer See Appendix A 2 Appendix A 2 Take Log Wi...

Страница 24: ...Go to Right click on Local Area Connection Properties Highlight For Windows XP and Windows 7 select Use the following IP address Click twice Double click on the FST Diag Utility Step 1 Select a Field...

Страница 25: ...n to these DOS prompts This step may take a few minutes depending on the chosen Log Type and computer speed When the Utility is finished you will be presented with a log of events that have occurred S...

Страница 26: ...R and LER RTC Unused RUN The RUN LED will start flashing 20 seconds after power indicating normal operation ERR The SYS ERR LED will go on solid 15 seconds after power up It will turn off after 5 seco...

Страница 27: ...SNVT_count_inc_f Outside Temp AI 9 AI 9 nvoXXOutsideTmp SNVT_count_inc_f Flame Signal AI 10 AI 10 nvoXXFlameSignal SNVT_count_inc_f CH Setpoint AV 11 AO 11 nvi nvoXXCHSP SNVT_count_inc_f DHW Setpoint...

Страница 28: ...on BI 43 DI 43 nvoXXFrstPrtctn SNVT_switch DHW Mode BI 44 DI 44 nvoXXDHWMode SNVT_switch CH Mode BI 45 DI 45 nvoXXCHMode SNVT_switch ET Month AI 46 AI 46 nvoXXETMonth SNVT_count_inc_f ET Day AI 47 AI...

Страница 29: ...nk of DIP switches below ProtoCessor A3 A8 DIP switches are disabled ProtoNode RER ProtoCarrier DIP Switches ProtoCessor DIP Switches Remove Cover Profile FPC N34 103 126 0710 S0 S1 S2 S3 A1 A2 A3 A4...

Страница 30: ...bus RTU 5 ENVI Off Off On Off Off On Off Off Off Off Off Off Modbus TCP Modbus RTU 6 ENVI On Off On Off Off On Off Off Off Off Off Off Modbus TCP Modbus RTU 7 ENVI Off On On Off Off On Off Off Off Off...

Страница 31: ...Off On On Off On 13 Off Off Off Off On On On Off 14 Off Off Off Off On On On On 15 Off Off Off On Off Off Off Off 16 Off Off Off On Off Off Off On 17 Off Off Off On Off Off On Off 18 Off Off Off On Of...

Страница 32: ...Off Off On On On Off On Off 58 Off Off On On On Off On On 59 Off Off On On On On Off Off 60 Off Off On On On On Off On 61 Off Off On On On On On Off 62 Off Off On On On On On On 63 Off On Off Off Off...

Страница 33: ...f On On Off Off On On On 103 Off On On Off On Off Off Off 104 Off On On Off On Off Off On 105 Off On On Off On Off On Off 106 Off On On Off On Off On On 107 Off On On Off On On Off Off 108 Off On On O...

Страница 34: ...147 On Off Off On Off On Off Off 148 On Off Off On Off On Off On 149 On Off Off On Off On On Off 150 On Off Off On Off On On On 151 On Off Off On On Off Off Off 152 On Off Off On On Off Off On 153 On...

Страница 35: ...On Off Off Off Off Off On 193 On On Off Off Off Off On Off 194 On On Off Off Off Off On On 195 On On Off Off Off On Off Off 196 On On Off Off Off On Off On 197 On On Off Off Off On On Off 198 On On O...

Страница 36: ...ff On On On 231 On On On Off On Off Off Off 232 On On On Off On Off Off On 233 On On On Off On Off On Off 234 On On On Off On Off On On 235 On On On Off On On Off Off 236 On On On Off On On Off On 237...

Страница 37: ...5 cm L x 8 3 cm W x 4 1 cm H 4 5 x 3 2 x 1 6 in Weight 0 2 kg 0 4 lbs Operating Temperature 40 C to 75 C 40 F to167 F Surge Suppression EN61000 4 2 ESD EN61000 4 3 EMC EN61000 4 4 EFT Humidity 5 90 R...

Страница 38: ...s approval or which have been subjected to accident improper maintenance installation or application or on which original identification marks have been removed or altered This Limited Warranty also w...

Отзывы: