Protimeter BaleMaster GRN6165 Скачать руководство пользователя страница 1

Protimeter BaleMaster

®  

GRN6165

 User Instructions

AAS-INS6165, Rev. A

August 2017

Amphenol

Advanced Sensors

PROTIMETER

BaleMaster (GRN6165)

Protimeter Moisture Meter

Содержание BaleMaster GRN6165

Страница 1: ...Protimeter BaleMaster GRN6165 User Instructions AAS INS6165 Rev A August 2017 Amphenol Advanced Sensors PROTIMETER BaleMaster GRN6165 Protimeter Moisture Meter...

Страница 2: ...d Only operate the measuring instrument properly for its intended purpose and within the parameters specified in the technical data Readings from moisture meters are not definitive but are used to hel...

Страница 3: ...mc bales are in a safe condition for storage Greater than 15 mc bales are not in a safe condition for storage Additional drying is recommended d After use switch the instrument OFF by pressing and hol...

Страница 4: ...en thereafter will be displayed as normal and below you will see a second reading that shows if the material is measured above or below the original reading Reference mode can be useful when trying to...

Страница 5: ...GRN6165 Page 5 Measurements The numeric measurement and color LED will be shown as well as DRY green or AT RISK yellow or WET red based on the measurement shown 8 5 15 DRY Green 15 1 19 5 AT RISK Yel...

Страница 6: ...to enter the Reference Mode The display will be similar to the one shown on the next page To return to the normal measurement mode press again Settings Press and hold the button and switch on the uni...

Страница 7: ...be switched ON or OFF When it is ON the moisture condition will be displayed on the screen When it is OFF no indication is displayed on screen Use the button to turn ON OFF thesettings If the unit det...

Страница 8: ...the next setting turns the Buzzer ON or OFF To change the settings press the button If the unit detects no key press for 2 seconds in the Settings screen it moves to the next setting Pressing the but...

Страница 9: ...etting turns the Backlight ON or OFF To change the settings press the button If the unit detects no key press for 2 seconds in the Settings screen it moves to the next setting Pressing the button afte...

Страница 10: ...s 1 then the unit will automatically shut down after one minute when no key is pressed The duration will change based on the set time of 1 6 minutes If the Auto Off time is set to be 0 then the unit w...

Страница 11: ...ing While measuring if the reading needs to be frozen for any observation press during measurement A text HOLD will be displayed on the screen 8 BatteryReplacement A 550mAh battery will last continuou...

Страница 12: ...consists of BaleMaster instrument Part 6165 and Bale probe GRN6148 The Balemaster instrument is calibrated for Wheat Straw Measurement Range 8 5 36 8 mc 10PhysicalSpecifications Power 9V Alkaline 550m...

Страница 13: ...Protimeter BaleMaster GRN6165 Page 13 MODEL GRN6165 Meter POL6148 Bale Probe...

Страница 14: ...aster is a registered trademark of Amphenol Thermometrics Inc U S A Amphenol Thermometrics Inc 967 Windfall Road St Marys Pennsylvania 15857 USA T 1 814 834 9140 U K Amphenol Thermometrics U K Limited...