Supplied By www.heating spares.co Tel. 0161 620 6677
28
100EC
PROTHERM 100EC – CONVERSION TO LPG
Note:
Conversion must only be carried out by a competent person
•
Isolate boiler from the gas and electrical supplies.
•
Remove boiler casing, sealed chamber and combustion chamber cover as described in Installation/Servicing
Instructions.
•
Disconnect flame sense electrode.
•
Disconnect ignition lead at gas valve module.
•
Disconnect ignition earth lead.
•
Undo nuts securing gas supply pipe between burner and gas valve and remove pipe.
•
Undo two locking nuts securing burner to base of sealed chamber.
•
Pull main burner up and forward out of boiler.
Note:
The washer between the burner and burner gas supply must be kept to use in reassembly.
•
Fit new burner with marked diameter of injector
∅
0,73
mm to the boiler in reverse order to removal.
•
Readjust the gas valve.
GAS VALVE ADJUSTMENT
To adjust the minimum and maximum settings, proceed as follows:
•
Gain access to the rear of the controls housing.
•
Connect a manometer to the burner pressure test point
(2)
on the
gas valve.
Minimum setting
•
Start boiler in Central Heating mode, boiler is working in minimum
output for 100 seconds.
•
Adjust the gas valve minimum pressure using screw
(C)
on gas valve.
Turn clockwise to increase, anti-clockwise to decrease.
Maximum setting
•
Start boiler in Domestic Hot Water mode.
•
Adjust gas valve maximum pressure using screw
(B).
Turn clockwise
to increase, anti-clockwise to decrease.
Note:
It is first necessary to remove cover
(A)
to gain access to screw
(B).
Finaly
•
Disconnect manometer and check for gas soundness.
•
Check for gas soundness.
•
Replace the PCB box and all covers.
•
Stick the self-adhesive label (delivered with LPG conversion kit) bearing the information about the gas type and
the gas supply pressure on the visible place inside the boiler.
Inj. diam.
Pmin
Pmax
G20 (20 mbar)
1.20 mm
2.1 mbar
15.0 mbar
G30 (29 mbar)
0.73 mm
3.8 mbar
28.8 mbar
G31 (37 mbar)
0.73 mm
4.1 mbar
36.7 mbar
Содержание 100EC
Страница 2: ...Supplied By www heating spares co Tel 0161 620 6677...
Страница 19: ...Supplied By www heating spares co Tel 0161 620 6677 17 100EC FLUE CONFIGURATIONS Diagram 1 1...
Страница 27: ...Supplied By www heating spares co Tel 0161 620 6677 25 100EC SCHEMATIC WIRING DIAGRAM Diagram 25...
Страница 31: ...Supplied By www heating spares co Tel 0161 620 6677 29 100EC...
Страница 32: ...Supplied By www heating spares co Tel 0161 620 6677 26 January 2001...