EN
13
to enable the lighting to function independently of the
receiver switch status
(see diagram)
.
ATTENTION
Always check that the power rating of the connected
device is less than or equal to the switching capacity.
TRANSMITTER INSTALLATION
Preparation
Mount transmitter
(2)
and magnet
(3)
on the upper
window frame and the window sash in such a way that
the distance between the two housing components is
less than 7 mm. Use the supplied washers
(U)
for adjustment.
1. Mount the transmitter housing base at the determined
position, using the supplied double-sided adhesive pad.
Alternatively, there is a blanked hole in the bottom of
the housing. Remove the circuit board from the bottom
of the housing and carefully break open the hole. Use
the hole to screw the transmitter to the window frame.
Then replace the circuit board.
2. Press the upper part of the housing onto its base.
3. Mount the magnet housing bottom in the determined-
position, using the supplied adhesive pad.
ATTENTION
The distance between the transmitter and the
magnet must not exceed 7 mm!
4. Insert magnet and close with the housing cover.
(Table 1) Calculation table to determine the minimum opening of your window
0,2
2000
199
246
294
342
389
437
485
532
0,3
3000
252
311
369
427
486
544
603
661
0,4
4000
297
365
432
500
567
635
702
770
0,5
5000
337
413
488
563
639
714
790
865
0,6
6000
373
456
538
621
704
786
869
951
0,7
7000
406
495
585
674
763
852
942
1031
0,8
8000
437
532
628
723
819
914
1009
1105
0,9
9000
466
567
668
770
871
972
1073
1174
1
10000
493
600
707
813
920
1027
1133
1240
1,1
11000
519
631
743
855
967
1079
1191
1302
1,2
12000
544
661
778
895
1012
1128
1245
1362
1,3
13000
568
690
811
933
1055
1176
1298
1419
1,4
14000
591
717
843
970
1096
1222
1348
1475
1,5
15000
613
744
874
1005
1136
1266
1397
1528
Window area in m
2
m
2
cm
2
5 cm
6 cm
7 cm
8 cm
9 cm
10 cm
11 cm
12 cm
Maximum permissible exhaust air performance in m
3
/h
Gap opening measurement in cm