Configuration:
Connect the AC connector of the Protectli DC power adapter to the AC source.
Connect the output of the Protectli DC power adapter to the “IN” jack of the USP.
Connect the black tip plug of the DC cable into the “OUT” jack of the USP.
Connect the yellow tip plug of the DC cable into the DC input of the Vault.
Installation Options:
The UPS can be installed as a desktop unit or mounted on a wall using the enclosed mounting bracket and screws.
When using the bracket, remove the 2 corner screws at the bottom corners of the UPS, attach the bracket and reinsert
the corner screws.
LED Status:
Status
Description
LED Off
UPS not charged or both Input and Output disconnected
LED Flashing Green and Red
UPS charging and Vault connected or disconnected
LED Solid Green
UPS Fully charged
LED Solid Red
UPS powering the Vault, no input power to the UPS
LED Flashing Red Quickly
Overload, Vault pulling too much current
Storage:
When stored, the UPS will discharge over time based on the ambient temperature. The UPS should be fully charged be-
fore being put into storage. If the USP is in storage for a long time, it should be recharged every 3-5 months in order to
maintain the original capacity.
Safety:
Only use the UPS with the Protectli Vault according to the instructions in this guide.
Do not open the unit. There are no user serviceable parts.
Dispose of properly following applicable regulations.
Support:
If you have any
issues, please reach out to the Protectli support team at
http://protectli.com/support
Thanks,
Team Protectli