background image

Configuration:

Connect the AC connector of the Protectli DC power adapter to the AC source.
Connect the output of the Protectli DC power adapter to the “IN” jack of the USP.

Connect the black tip plug of the DC cable into the “OUT” jack of the USP.
Connect the yellow tip plug of the DC cable into the DC input of the Vault.     

Installation Options:

The UPS can be installed as a desktop unit or mounted on a wall using the enclosed mounting bracket and screws.

When using the bracket, remove the 2 corner screws at the bottom corners of the UPS, attach the bracket and reinsert 
the corner screws.

LED Status:

Status

Description

LED Off 

UPS not charged or both Input and Output disconnected

LED Flashing Green and Red

UPS charging and Vault connected or disconnected

LED Solid Green

UPS Fully charged

LED Solid Red

UPS powering the Vault, no input power to the UPS

LED Flashing Red Quickly

Overload, Vault pulling too much current

Storage:

When stored, the UPS will discharge over time based on the ambient temperature. The UPS should be fully charged be-
fore being put into storage. If the USP is in storage for a long time, it should be recharged every 3-5 months in order to 

maintain the original capacity. 

Safety:

Only use the UPS with the Protectli Vault according to the instructions in this guide.
Do not open the unit. There are no user serviceable parts.

Dispose of properly following applicable regulations.

Support:

If you have any

 issues, please reach out to  the Protectli support team at 

http://protectli.com/support

Thanks, 
Team Protectli

www.protectli.com

Отзывы: