background image

4

WARNING: Always wear safety glasses and other

necessary protective devices or apparel when installing
or working with anchor bolts.

CAUTION: Not recommended for use in lightweight

masonry such as block or brick.

CAUTION: Use of carbide drill bits manufactured within

ANSI B94.12-77 drill bit diameter requirements is
recommended for installation  of this anchor bolt. Use of
core drills is not recommended to drill holes for use with
this anchor.

CAUTION: Not recommended for use in new concrete which has not had sufficient time to cure.

WARNING: User must read and follow the supplied instructions (or instructions supplied with non-supplied equipment) for

the associated equipment used in this kit (i.e. full body harness, shock absorbing lanyard with attached rope grab, and
rope lifeline). Failure to read and follow all instructions could result in serious or fatal injury.

IMPORTANT: For special (custom) versions of this product, follow the instructions herein (i.e. Compliance in a Can). If

enclosed, see attached supplement for additional instructions to be followed when using a customized product. If instructions
for any component of the system are missing or unusable, contact PROTECTA for a replacement set before use.

3.14 MAKING CONNECTIONS: When using a hook to make a connection, be certain accidental disengagement (rollout)

cannot occur.  Rollout occurs when interference between a hook and the mating connector causes the hook’s gate
or keeper to accidentally open and release.  Self-locking snap hooks and self-closing and locking carabiners must
be used to reduce the possibility of rollout when making connections.  Do not use hooks or connectors that will not
completely close over the attachment object.  Never use non-locking snap hooks.  Follow supplied instructions for
each system component.

3.15 CONNECTING TO THE CONCRETE ANCHOR: Connection to the installed concrete anchor may be made using a

self locking snap hook or self closing carabiner ONLY.  Do not use a knot to connect a lifeline to the concrete
anchor.  Do not pass lanyard or lifeline through the anchor ring and hook back into lanyard or line.  When
connecting, make sure connections are fully closed and locked.  When using a shock absorbing lanyard (SAL),
ensure that the shock absorber end of the lanyard is connected closest to the dorsal D-ring of the harness (does
not apply to “Compliance in a Can” kit as the SAL is permanently attached to rope grab).  If using a self retracting
lifeline, make sure device is properly positioned so that retraction is not hindered.  Always protect lifeline/lanyard
from contact against sharp edges or abrasive surfaces.  Make sure all connections are compatible in size, shape,
and strength.  Never connect more than one personal fall arrest system to any single concrete anchor at a time.

WARNING: User must read and follow the supplied instructions (or instructions supplied with non-supplied equipment) for

the associated equipment used in this kit (i.e. full body harness, shock absorbing lanyard with attached rope grab, and
rope lifeline).  Failure to read and follow all instructions could result in serious or fatal injury.

IMPORTANT: For special (custom) versions of this product, follow the instructions herein (i.e. Compliance in a Can).  If

enclosed, see attached supplement for additional instructions to be followed when using a customized product.  If
instructions for any component of the system are missing or unusable, contact PROTECTA for a replacement set before use.

1. Drill and clean
hole.

2. Drive assembled
bolt into hole.

3. Tighten  to
appropriate torque.

Figure 3 - Installing Anchor Bolts

Содержание AJ720A

Страница 1: ... or more anchors i e horizontal lifeline system and do not hang lift or support tools or equipment from the attached anchor 1 2 FALL ARREST APPLICATION For this application as part of the Compliance in a Can personal fall arrest system the AJ720A Concrete Anchor is to be used as part of a complete fall arrest system This system includes a full body harness rope lifeline and rope grab with attached...

Страница 2: ...given in A or B above must be met at each anchor installation point independently EXAMPLE If two anchors are installed on to a roof structure each anchor must be independently capable of supporting 5 000 lbs or 3 600 lbs with certification 3 0 USE AND OPERATION WARNINGS Do not alter or intentionally misuse this equipment Consult PROTECTA when using this equipment in combination with components or ...

Страница 3: ...nst unprotected sharp edges Do not loop lanyard around small diameter structural members If working with this equipment near sharp edges is unavoidable protection against cutting must be provided by using a heavy pad or other means over the exposed sharp edge 3 10 RESCUE Should a fall occur the employer must have a rescue plan and the means to implement it in place 3 11 AFTER A FALL Any equipment ...

Страница 4: ...attachment object Never use non locking snap hooks Follow supplied instructions for each system component 3 15 CONNECTINGTOTHE CONCRETE ANCHOR Connection to the installed concrete anchor may be made using a self locking snap hook or self closing carabiner ONLY Do not use a knot to connect a lifeline to the concrete anchor Do not pass lanyard or lifeline through the anchor ring and hook back into l...

Страница 5: ...s securely attached at all times STEP 5 Inspect each system component or subsystem per written instructions from manufacturer inspection procedures for other elements of the Compliance in a Can kit are included in this manual STEP 6 Record the inspection date and results in the inspection log included in the back of this manual NOTE If inspection reveals a defective condition remove the unit from ...

Страница 6: ...6 Anchor Plate Anchor Bolt 7 3 DIMENSIONS ...

Страница 7: ... e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A 8 0 INSPECTION AND MAINTENANCE LOG DATE OF MANUFACTURE _______________________________________________________________________ MODEL NUMBER ______________________________________________________________________________ DATE PURCHASED _______________________________...

Страница 8: ... Wing MN 55066 1837 Mississauga Ontario L5S 1Y9 Toll Free 800 328 6146 Toll Free 800 387 7484 Phone 651 388 8282 Phone 905 795 9333 Fax 651 388 5065 Fax 905 795 8777 www protecta com www protecta com Form 5902241 Rev A I S O 9 0 0 1 Certificate No FM 39709 ...

Отзывы: