14
S-PARK
- rev. 1.1_06_2020
3.9
Quickstart guide
Once the installation is mechanically and electrically completed,
close the cabinet door and proceed to the following steps:
• Boom programming:
p. 17.
IMPORTANT:
the programming procedure has to be repeated
every time anything on the boom changes: weight, length,
balancing, limit switch, run.
• Adjust settings.
• Store remote controls if expected.
Refer to parameter
as START
A.2 Remote control storage as START2 pedestria
p. 16 - 17.
• Double chek the overall operational status –
safety devices
particularly.
Refer to
p. 14, to get a closer detailed
view of the boom operation logic.
Refer to
p. 15 for settings configuration.
3.10 Locking the upper top cover
After completing the whole barrier installation and regulation, close
the cabinet door without locking.
Proceed to wire the blinker integrated in the cover to the control unit.
Fit the upper cover and secure it with screws M3, refer to
Picture 28.
Lock the cabinet door by key, in this way the embedded safety
microswitch will activate.
The microswitch allows to carry out maintenance in safety conditions,
since it stops any possible commands from remote (additional
information available at
Chapter P.6 Door switch set up
p. 19.
Picture 28
SCREWS M3X20
SCREWS M3X20
CABINET
BLINKER
CONNECTOR
COVER
4. OPERATION
4.1
Working cycle
During normal operation the barrier could be in one of the following
mode:
• STILL MODE: Just when the barrier is in STILL mode it is possible
to program it or adjust settings.
The blinker is OFF and the display is in stand-by “
_ _
“.
• OPENING MODE: The blinker flashes slowly and the display
shows “/ \” opening.
If during opening the barrier detects an obstacle, the boom
reverts to closing position, remains still for 10 seconds (the
display shows count-down) and then starts to open again.
• AUTOMATIC CLOSING COUNTDOWN:
When countdown begins the blinker starts flashing briefly for
a few seconds switiching then to fixed light.
If a start command is sent during countdown, the automatic
closing is suspended.
Refer to
, p. 18.
• CLOSING MODE: If during closing the barrier detects an
obstacle or photocell’s beam is cut, the boom reverts to OPENING
position.
4.1.1
LED strip signalling mode - legenda
Barrier’s status
Signalling
Unidentified position (no full
duty cycle has been performed
yet)
Red light ON, blinker may slowly
flash.
The boom might be in low position,
Still mode, not in opening
position
Red light ON, blinker may slowly
flash.
The boom might be in low position,
During opening
Red light ON.
Opening position, NO automatic
closing or automatic closing
countdown over 5 seconds
Green ligh ON.
In opening position, automatic
closing countdown below 5
seconds
Red light ON.
During closing
Red light flashing
4.1.2
Automatic closing after power cut
Once the power supply is restored, after 15 seconds the barrier
starts closing, if all the following conditions have been fulfilled:
• Parameter
H.4 Automatic closing after power cut
p. 18 is
activated.
• Parameter
C.4 LH and RH boom configuration
p. 18 is not
set to position 2 (factory setting).
• No wired/radio command is sent, no key is pressed.
During the 15 seconds the system doubles check that all the a.m.
tips have been respected.
If this is the case, the blinker will flash shortly to confirm closing will
start soon.