background image

Chapter  5  BIOS  Setup 

 

 

 

 

BA-2501 SERIES USER MANUAL

 

Page: 5-30

 

 

5.4.10  Advanced – Network Stack Configuration 

Menu Path 

Advanced > Network Stack Configuration 

The 

Network  Stack  Configuration

  allows  users  to  enable/disable  UEFI  Network 

Stack,  IPv4/IPv6  PXE  (Pre-Boot  Execution)  support  and  configure  PXE  boot  wait 

time and detects the media presence. 

 

PXE  allows  a  workstation  to  boot  from  a  server  on  a  network  prior  to  booting  the 

operating  system  on  the  local  hard  drive.  A  PXE-enabled  workstation  connects  its 

NIC to the LAN via a jumper, which keeps the workstation connected to the network 

even when the power is turned off. 

 

Network Stack Configuration Screen 

 

BIOS Setting

 

Options

 

Description/Purpose

 

Network Stack 

- Disabled 

- Enabled 

Enables or Disables UEFI Network 

Stack. 

Ipv4 PXE Support 

- Disabled 

- Enabled 

Enables Ipv4 PXE Boot Support. If 

disabled, Ipv4 PXE boot option will 

not be created. 

Ipv6 PXE Support 

- Disabled 

- Enabled 

Enables Ipv6 PXE Boot Support. If 

disabled, Ipv6 PXE boot option will 

not be created. 

Содержание BA-2501

Страница 1: ...USER MANUAL BA 2501 ATX Intel 6th 7th Gen CoreTM i7 i5 i3 Pentium Celeron Processor BA 2501 M1...

Страница 2: ...produce or transmit in any form or by any means electronic or mechanical including photocopying and recording DISCLAIMER This user s manual is meant to assist users in installing and setting up the sy...

Страница 3: ...ser will be required to correct the interference at his own expense You are cautioned that any change or modifications to the equipment not expressly approve by the party responsible for compliance co...

Страница 4: ...BA 2501RA N 3 4 3 2 2 Jumper Setting of BA 2501RA N 3 6 3 2 3 I O View of BA 2501RA N 3 7 3 3 HOW TO SET JUMPERS 3 8 3 4 Setting Connectors and Jumpers 3 10 3 4 1 COM1 and COM2 PORT 3 10 3 4 2 COM3 C...

Страница 5: ...LECTION 3 29 3 4 19 CASE OPEN DETECTION SELECTION 3 30 3 4 20 MINI PCIE VOLTAGE SELECTION 3 31 3 4 21 PARALLEL PORT LPT CONNECTOR For C236 SKU only 3 32 3 4 22 I2C WAFER 3 33 3 4 23 MINI PCI EXPRESS S...

Страница 6: ...ility 4 11 4 10 Installing Intel USB 3 0 eXtensible Host Controller Utility 4 12 5 BIOS SETUP 5 1 5 1 Introduction 5 2 5 2 Accessing Setup Utility 5 3 5 3 Main 5 6 5 4 Advanced 5 8 5 4 1 Advanced CPU...

Страница 7: ...5 4 10 Advanced Network Stack Configuration 5 30 5 4 11 Advanced USB Configuration 5 31 5 5 Chipset 5 32 5 5 1 Chipset System Agent SA Configuration 5 33 System Agent SA Configuration Memory Configur...

Страница 8: ...Boot CSM Configuration 5 46 5 8 Save Exit 5 48 Appendix A Technical Summary A 1 BA 2501 Block Diagram A 2 Interrupt Map A 3 I O MAP A 8 Memory Map A 11 DMA Map A 13 Configuring WatchDog Timer A 14 Fl...

Страница 9: ...vi Revision History The revision history of BA 2501 User Manual is described below Version No Revision History Date 1 0 Initial Release 08 01 2017...

Страница 10: ...501 SERIES USER MANUAL Page 1 1 1 Introduction This chapter provides the introduction for the BA 2501 system as well as the framework of the user manual The following topics are included About This Ma...

Страница 11: ...ions Read the safety reminders carefully on how to take care of your system properly Chapter 3 Hardware Configuration This chapter outlines the locations of the motherboard components and their respec...

Страница 12: ...ormation for the BA 2501 system It describes the package contents and outlines the system specifications The following topics are included Package List System Specification Safety Precautions Experien...

Страница 13: ...e 2 2 2 1 Packing List If you discover any of the items listed above are damaged or lost please contact your local distributor immediately Item Q ty BA 2501 1 Quick Reference Guide 1 Manual Driver DVD...

Страница 14: ...on ECC C236 Q170 H110 BIOS AMI UEFI BIOS Hardware Monitor CPU System FAN smart FAN connector 2 12V 5V 5Vsb Vcore 1 x CPU Fan 4 pins 1 System Fan 1 pins 1 System Fan 3 pins Watchdog Timer 1 255 seconds...

Страница 15: ...r for C236 SKU only LAN Dual ports to support 10 100 1000Mbps RJ45 rear I O LAN1 Intel PHY I219 LM 10 100 1000 Mbps LAN2 Intel PHY I211 AT 10 100 1000 Mbps Supports Wake On LAN PXE GPIO DIO 8bits GPIO...

Страница 16: ...io 1 x Front Panel Audio Header 2 x 5 pin TPM on board option Co lay TPMI1 2 TPM2 0 chip Case Open Detection 1 x 2 pin jumper for case intrusion detection Shock 15G peak to peak 11ms duration non oper...

Страница 17: ...a hot place to a cold place and vice versa because condensation may occur inside the system Protect your BA 2501 from strong vibrations which may cause hard disk failure Do not place the system too c...

Страница 18: ...n This chapter contains helpful information about the jumper connector settings and component locations The following sections are included Jumper Connector Quick Reference Table Component Locations C...

Страница 19: ...V 12V Selection JPCOM4 Clear CMOS Data Selection JCMOS1 CONNECTOR Description NAME Power Input Connectors ATX_PWR1 ATX_PWR2 Line In Line Out and MIC In Port AUDIO1 COM Port COM1 COM2 COM Connectors CO...

Страница 20: ...501 SERIES USER MANUAL Page 3 3 CONNECTOR Description NAME SATA5 SATA6 Universal Serial Bus 3 0 Connector USB1 VGA Port VGA Parallel Port LPT Connector for C236 SKU only LPT1 Front Audio Line In Line...

Страница 21: ...sure both the system and peripheral devices are turned OFF as sudden surge of power could damage sensitive components Make sure BA 2501 is properly grounded CAUTION Observe precautions while handling...

Страница 22: ...ANUAL Page 3 5 CAUTION Always touch the motherboard components by the edges Never touch components such as a processor by its pins Take special cares while you are holding electronic circuit boards by...

Страница 23: ...BA 2501 SERIES USER MANUAL Page 3 6 3 2 2 Jumper Setting of BA 2501RA N Note C236 Q170 SKU supports SATA1 6 JUDIMM1 4 PCI_E1 2 available H110 SKU only supports SATA1 4 JUDIMM1 3 PCI_E1 2 available LPT...

Страница 24: ...Chapter 3 Hardware Configuration BA 2501 SERIES USER MANUAL Page 3 7 3 2 3 I O View of BA 2501RA N PS 2 keyboard mouse connector COM2 VGA LAN 1 LAN 2 COM 1 DVI D 4 x USB Ports Audio Connector...

Страница 25: ...iguration by open or close pins The jumper can be combined into sets that called jumper blocks When the jumpers are all in the block you have to put them together to set up the hardware configuration...

Страница 26: ...in Jumper looks like this Jumper Cap looks like this 3 pin Jumper looks like this Jumper Block looks like this Jumper Settings Looks like this 3 pin Jumper 2 3 pin close enabled Looks like this Jumper...

Страница 27: ...D 6 DSR 7 RTS 8 CTS 9 RI COM2 COM2 Connector selectable as RS 232 422 485 The pin assignments are as follows PIN Signal RS 232 RS 422 RS 485 10 DCD TX RS 485 11 RX TX RS 485 12 TX RX NC 13 DTR RX NC 1...

Страница 28: ...S 232 PIN ASSIGNMENT PIN ASSIGNMENT 1 DCD 6 DSR 2 RX 7 RTS 3 TX 8 CTS 4 DTR 9 RI 5 GND Note 1 COM3 COM4 Pin 9 is selectable for RI 5V or 12V by jumper setting Default setting is RI please see COM3 and...

Страница 29: ...OM3 and COM4 PIN9 DEFINITION SELECTION GUIDE Jumper Name JPCOM3 JPCOM4 Description COM3 and COM4 RI Voltage Selection Selection Jumper Setting Pin Closed Jumper Illustration RI 1 2 Default Setting 5 6...

Страница 30: ...PIN HEADER Connector Location JDIO1 Description General Purpose Input Output Pin Header PIN ASSIGNMENT PIN ASSIGNMENT 1 VCC5 2 VCC12 3 DIN1 4 DOUT1 5 DIN2 6 DOUT2 7 DIN3 8 DOUT3 9 DIN4 10 DOUT4 11 DI...

Страница 31: ...5 KEYBOARD MOUSE PORT Port Name KB_MS1 Description PS 2 Keyboard Mouse Port Mouse PIN ASSIGNMENT PIN ASSIGNMENT 12 NC 11 MSCLK 10 VCC5 9 GND 8 NC 7 MSDATA Keyboard PIN ASSIGNMENT PIN ASSIGNMENT 6 NC 5...

Страница 32: ...N ASSIGNMENT 1 TMDS_D2 9 TMDS_D1 17 TMDS_D0 2 TMDS_D2 10 TMDS_D1 18 TMDS_D0 3 GND 11 GND 19 GND 4 NC 12 NC 20 NC 5 NC 13 NC 21 NC 6 TMDS_CLK 14 VCC5 22 GND 7 TMDS_DATA 15 GND 23 TMDS_D3 8 NC 16 TMDS_H...

Страница 33: ...USER MANUAL Page 3 16 3 4 7 VGA PORT Port Name VGA Description VGA Video Graphics Array Connector PIN ASSIGNMENT 1 CRT_RED 2 CRT_GREEN 3 CRT_BLUE 4 NC 5 GND 6 NC 7 GND 8 GND 9 CRT_VCC 10 GND 11 NC 12...

Страница 34: ...A 2501 SERIES USER MANUAL Page 3 17 3 4 8 FRONT PANEL CONNECTOR Connector Location FP1 Description Front Panel Connector PIN ASSIGNMENT PIN ASSIGNMENT 1 HDD_LED 2 PWR_LED 3 HDD_LED 4 PWR_LED 5 GND 6 P...

Страница 35: ...T 1 MDI_P0 2 MDI_N0 3 MDI_1P 4 MDI_2P 5 MDI_2N 6 MDI_1N 7 MDI_P3 8 MDI_N3 LAN1 LED Indicator Left Side LED Green Color On7 10 100 1000Mbps LAN Speed Indicator Orange Color On8 Giga LAN Speed Indicator...

Страница 36: ...GNMENT 1 MDI_P0 2 MDI_N0 3 MDI_1P 4 MDI_2P 5 MDI_2N 6 MDI_1N 7 MDI_P3 8 MDI_N3 LAN2 LED Indicator Left Side LED Green Color On7 10 100 1000Mbps LAN Speed Indicator Orange Color On8 Giga LAN Speed Indi...

Страница 37: ...Chapter 3 Hardware Configuration BA 2501 SERIES USER MANUAL Page 3 20 PIN ASSIGNMENT PIN ASSIGNMENT B1 VCC B9 USB3_TX_P4 B2 USB_N4 B8 USB3_TX_N4 B3 USB_P4 B7 GND B4 GND B6 USB3_RX_P4 B5 USB3_RX_N4...

Страница 38: ...ription Line In Line Out Microphone The connector can also support only Microphone Line In PIN ASSIGNMENT 32 HD_LINE IN L 33 GND 34 GND 35 HD_LINE IN R Line Out PIN ASSIGNMENT 22 LINE OUT L 23 GND 24...

Страница 39: ...LCDGND 25 LCDGND 26 LCDGND 27 EDP_LVDS_HPD 28 BackLight GND 29 BackLight GND 30 GND 31 GND 32 EDP_BKLTEN 33 EDP_BKLTCTL 34 NC 35 NC 36 VCC12 37 VCC12 38 VCC12 39 VCC12 40 VCC12 eDP Embedded DisplayPor...

Страница 40: ...R MANUAL Page 3 23 3 4 12 FRONT PANEL AUDIO CONNECTOR Connector Location J1 Description Front Panel Audio Connector PIN ASSIGNMENT PIN ASSIGNMENT 1 MIC1 L 6 MIC1 R 2 GND 7 GND 3 LINE IN L 8 LINE IN R...

Страница 41: ...SERIES USER MANUAL Page 3 24 3 4 13 HARDWARE POWER FAILURE SELECTION Connector Location JP1 Description Hardware Power Failure Selection Selection Jumper Setting Pin Closed Jumper Illustration Enable...

Страница 42: ...S USER MANUAL Page 3 25 3 4 14 FLASH DESCRIPTOR OVERRIDE SELECTION Connector Location JP3 Description Flash Descriptor Override Selection Selection Jumper Setting Pin Closed Jumper Illustration Enable...

Страница 43: ...501 SERIES USER MANUAL Page 3 26 3 4 15 LAN2 ENABLE DISABLE SELECTION Connector Location JP5 Description LAN2 Enable Disable Selection Selection Jumper Setting Pin Closed Jumper Illustration Enable 1...

Страница 44: ...01 SERIES USER MANUAL Page 3 27 3 4 16 MINI PCIE and MSATA SELECTION Connector Location JP6 Description Mini PCIE and mSATA Selection Selection Jumper Setting Pin Closed Jumper Illustration mSATA 1 2...

Страница 45: ...n BA 2501 SERIES USER MANUAL Page 3 28 3 4 17 VCCIO VOLTAGE SELECTION Connector Location JP10 Description VCCIO Voltage Selection Selection Jumper Setting Pin Closed Jumper Illustration 1 0V 1 2 JP10...

Страница 46: ...UAL Page 3 29 3 4 18 PCH CONFIGURATION RECOVERY SELECTION Connector Location JP11 Description PCH Configuration Recovery Selection Selection Jumper Setting Pin Closed Jumper Illustration Normal 1 2 De...

Страница 47: ...SER MANUAL Page 3 30 3 4 19 CASE OPEN DETECTION SELECTION Connector Location JP12 Description Case Open Detection Selection Selection Jumper Setting Pin Closed Jumper Illustration Case Closed 1 2 1 JP...

Страница 48: ...2501 SERIES USER MANUAL Page 3 31 3 4 20 MINI PCIE VOLTAGE SELECTION Connector Location JP13 Description Mini PCIE Voltage Selection Selection Jumper Setting Pin Closed Jumper Illustration 3 3V 1 2 JP...

Страница 49: ...PT1 Description Parallel Port Connector PIN ASSIGNMENT PIN ASSIGNMENT 1 PRN_STRBJ_R 14 PRN_AFD 2 PRN_R_D0 15 PRN_ERRJ 3 PRN_R_D1 16 PRN_INIT 4 PRN_R_D2 17 PRN_SLIN 5 PRN_R_D3 18 GND 6 PRN_R_D4 19 GND...

Страница 50: ...Chapter 3 Hardware Configuration BA 2501 SERIES USER MANUAL Page 3 33 3 4 22 I2C WAFER Connector Location J17 Description I2C Wafer PIN ASSIGNMENT 1 PRN_STRBJ_R 2 PRN_R_D0 3 PRN_R_D1 4 PRN_R_D2 J17 1...

Страница 51: ...3 3V_SB 3 NC 4 GND 5 NC 6 1 5V 7 CLKREQ 8 NC 9 GND 10 NC 11 REFCLK 12 NC 13 REFCLK 14 NC 15 GND 16 NC 17 NC 18 GND 19 NC 20 NC 21 GND 22 PERST 23 PE_RX_N 24 3 3V_SB 25 PE_RX_P 26 GND 27 GND 28 1 5V 29...

Страница 52: ...B22 GND B23 HSOP2 A22 HSIN1 A23 GND B24 HSON2 B25 GND A24 GND A25 HSIP2 B26 GND B27 HSOP3 A26 HSIN2 A27 GND B28 HSON3 B29 GND A28 GND A29 HSIP3 B30 RSVD B31 PRSNT 2 A30 HSIN3 A31 GND B32 GND B33 HSOP...

Страница 53: ...ND B64 GND B65 GND A64 HSIP11 A65 HSIN11 B66 HSOP12 B67 HSON12 A66 GND A67 GND B68 GND B69 GND A68 HSIP12 A69 HSIN12 B70 HSOP13 B71 HSON13 A70 GND A71 GND B72 GND B73 GND A72 HSIP13 A73 HSIN13 B74 HSO...

Страница 54: ...B6 SMB_DATA B5 SMB_CLK A6 NC A5 NC B8 3 3V B7 GND A8 NC A7 NC B10 3 3V_AXU B9 NC A10 3 3V A9 3 3V B11 WAKE A11 PERST B12 RSVD B13 GND A12 GND A13 REFCLK B14 HSOP0 B15 HSON0 A14 REFCLK A15 GND B16 GND...

Страница 55: ...3 3V A20 AD31 A21 AD29 B22 AD28 B23 AD26 A22 GND A23 AD27 B24 GND B25 AD24 A24 AD25 A25 3 3V B26 GNT2 B27 3 3V A26 C BE3 A27 AD23 B28 AD22 B29 AD20 A28 GND A29 AD21 B30 GND B31 AD18 A30 AD19 A31 3 3V...

Страница 56: ...OR Connector Location CPU_FAN1 SYS_FAN1 Description CPU Fan Connector CPU_FAN1 System Fan Connector 1 SYS_FAN1 PIN ASSIGNMENT 1 GND 2 VCC12 3 CPU_FANTAC 4 CPU_FANCTRL Connector Location SYS_FAN2 Descr...

Страница 57: ...n SATA Connectors SATA1 Pin Assignment PIN ASSIGNMENT 1 GND 2 SATA_TXP0 3 SATA_TXN0 4 GND 5 SATA_RXN0 6 SATA_RXP0 7 GND SATA2 Pin Assignment PIN ASSIGNMENT 1 GND 2 SATA_TXP1 3 SATA_TXN1 4 GND 5 SATA_R...

Страница 58: ...Pin Assignment PIN ASSIGNMENT 1 GND 2 SATA_TXP4 3 SATA_TXN4 4 GND 5 SATA_RXN4 6 SATA_RXP4 7 GND Note SATA5 is not supported in PCH H110 SATA5 is available for C236 Q170 SKU SATA6 Pin Assignment PIN A...

Страница 59: ...CTOR Connector Location USB1 Description Internal USB 3 0 Connector 1 10 11 19 USB1 PIN ASSIGNMENT PIN ASSIGNMENT 1 VCC5 11 USB2_P 2 USB3_RX_N 12 USB2_N 3 USB3_RX_P 13 GND 4 GND 14 USB3_TX_P 5 USB3_TX...

Страница 60: ...USER MANUAL Page 3 43 3 4 29 INTERNAL USB 2 0 CONNECTOR Connector Location USB2 USB3 Description Internal USB 2 0 Connector PIN ASSIGNMENT PIN ASSIGNMENT 1 VCC5 2 VCC5 3 USB2_N 4 USB2_N 5 USB2_P 6 US...

Страница 61: ...30 DISPLAY PORT CONNECTOR OPTION Connector Location DP1 Description DisplayPort Connector PIN ASSIGNMENT PIN ASSIGNMENT 1 DATA0 2 GND 3 DATA0 4 DATA1 5 GND 6 DATA1 7 DATA2 8 GND 9 DATA2 10 DATA3 11 GN...

Страница 62: ...e Configuration BA 2501 SERIES USER MANUAL Page 3 45 3 4 31 SPEAKER CONNECTOR Connector Location JSPEAKER Description Speaker Connector PIN ASSIGNMENT 1 SPKR_VCC 2 SPKR_SIGNAL 3 SPKR_SIGNAL 4 SPKR_SIG...

Страница 63: ...ion ATX Connector PIN ASSIGNMENT PIN ASSIGNMENT 1 3 3V 13 3 3V 2 3 3V 14 12V 3 GND 15 GND 4 5V 16 PSON 5 GND 17 GND 6 5V 18 GND 7 GND 19 GND 8 POK 20 5V 9 5V_SB 21 5V 10 12V 22 5V 11 12V 23 5V 12 12V...

Страница 64: ...33 LPC CONNECTOR Connector Location JLPC1 Description LPC Connector PIN ASSIGNMENT PIN ASSIGNMENT 1 CLK 2 GND 3 FRAME 4 NC 5 RESET 6 VCC5 7 LAD3 8 LAD2 9 VCC3 10 LAD1 11 LAD0 12 GND 13 SMBCLK 14 SMBDA...

Страница 65: ...main power of the PC Step2 Close JCMOS1 pins 1 2 for 6 seconds by a cap Step3 Remove the cap which is just used on JCMOS1 1 2 so that JCMOS1 returns to OPEN Step4 Power on the PC and the PC will then...

Страница 66: ...ipset Software Installation Utility Installing VGA Driver Utility Installing LAN Driver Utility Installing Sound Driver Utility Installing KMDF Driver Utility Installing Intel Management Engine Compon...

Страница 67: ...D Graphics Family For VGA driver installation D BA 2501_V1 0 Platform 3_Audio Win7 32Bit D BA 2501_V1 0 Platform 3_Audio Win7 8 1 10 64Bit Realtek ALC888S VD2 GR HD Audio codec System Software D BA 25...

Страница 68: ...501_V1 0 Platform 8_Serial IO Win8 1 64Bit D BA 2501_V1 0 Platform 8_Serial IO Win7 8 1 10 64Bit Intel Serial I O Driver D BA 2501_V1 0 Platform 9_USB3 0 Win7 32Bit 64Bit Intel USB 3 0 eXtensible Host...

Страница 69: ...Intel Chipset Components in the Device Manager Intel Chipset Software Installation Utility The utility pack is to be installed only for Windows 7 32 64 bit Windows 8 1 64 bit Windows 10 64 bit and it...

Страница 70: ...ously To install the VGA driver utility follow the steps below 1 Connect the USB DVD ROM device to BA 2501 and insert the driver disk 2 Enter the Graphics folder where the driver is located depending...

Страница 71: ...ollow the steps below 1 Connect the USB DVD ROM device to BA 2501 and insert the driver disk 2 Enter the LAN folder where the driver is located depending on your OS platform 3 Click Setup exe file for...

Страница 72: ...USB DVD ROM device to BA 2501 and insert the driver disk 2 Open the Audio folder where the driver is located depending on your OS platform 3 Click the Setup exe file for driver installation 4 Follow...

Страница 73: ...o a DVD ROM device 2 For Windows 7 only Enter the KMDF folder where the installation driver file is located 3 For Windows 7 only Click the Setup kmdf 1 11 exe file for driver installation Installation...

Страница 74: ...wing Pre operating system user interface for RAID volume management Ability to create delete and reset RAID volumes RAID recovery User Interface To enter the Intel Rapid Storage Technology option ROM...

Страница 75: ...nnect the USB DVD ROM device to BA 2501 and insert the driver disk 2 Enter the RST folder where the driver is located 3 Select Windows 7 32 64 bit Windows 8 1 64 bit Windows 10 64 bit for your OS plat...

Страница 76: ...ng the OS 5 Once the installation is completed shut down the system and restart BA 2501 for the changes to take effects 4 9 Installing Intel Serial I O Driver Utility To install the Serial I O Driver...

Страница 77: ...sor or Intel Celeron Processor N J Series Intel 5th generation Intel CoreTM Processors Intel CoreTM M Processor Intel 6th generation Intel CoreTM processors Intel 100 Series Chipset Family To install...

Страница 78: ...Utilities The information of the system configuration is saved in battery backed CMOS RAM and BIOS NVRAM so that the Setup information is retained when the system is powered off The BIOS Setup Utilit...

Страница 79: ...n the operating system and platform firmware The interface consists of data tables that contain platform related information boot service calls and runtime service calls that are available to the oper...

Страница 80: ...onfiguration from the BIOS Setup Utility when any of the following conditions occurs 1 You are starting your system for the first time 2 You have changed the hardware in your system or the hardware be...

Страница 81: ...eys to highlight the individual menu items As you highlight each item a brief description of the highlighted selection will appear on the right side of the screen The language of the BIOS setup menu i...

Страница 82: ...to the left or right and Select a different item move the cursor from the selected item upwards or downwards Enter Execute the command or select the sub menu F2 Load the previous configuration values...

Страница 83: ...Setting Options Description Purpose BIOS Vendor No changeable options Displays the name of the BIOS vendor Core Version No changeable options Displays the current BIOS core version Compliancy No chan...

Страница 84: ...IOS Setting Options Description Purpose to increase decrease it The Day is automatically changed System Time Hour minute second Sets the system time The format is Hour Minute Second Users can directly...

Страница 85: ...Screen BIOS Setting Options Description Purpose CPU Configuration Sub Menu CPU Configuration Parameters SATA Configuration Sub Menu SATA Device Options Settings PCH FW Configuration Sub Menu Manageme...

Страница 86: ...iguration provides advanced CPU settings and some information about CPU CPU Configuration Screen BIOS Setting Options Description Purpose Type No changeable options Displays the CPU Type ID No changea...

Страница 87: ...en enabled VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Hyper threading Disabled Enabled When Disabled only one thread per enabled core is enabled 5 4 2 Advan...

Страница 88: ...erve No changeable options Indicates whether the connected SATA device supports Software Setting Preservation SSP Port 1 6 Port 1 4 for H110 only Disabled Enabled Enables or Disables SATA Port Device...

Страница 89: ...n Menu Path Advanced Trusted Computing The Trusted Computing allows users to enable disable BIOS support for security device The operating system will now show Security Device The TCG EFI protocol and...

Страница 90: ...start in order to change State of Security Device Device Select TPM 1 2 TPM 2 0 Auto TPM 1 2 will restrict support to TPM 1 2 devices TPM 2 0 will restrict support to TPM 2 0 devices Auto will support...

Страница 91: ...Video Repost ACPI Settings Screen BIOS Setting Options Description Purpose Enable Hibernation Disabled Enabled Enables or Disables System ability to Hibernate OS S4 Sleep State This option may be not...

Страница 92: ...ters of Serial Port 1 COMA Serial Port 2 Configuration Sub menu Configures Parameters of Serial Port 2 COMB Serial Port 3 Configuration for C236 Q170 only Sub menu Configures Parameters of Serial Port...

Страница 93: ...guration Screen BIOS Setting Options Description Purpose Use This Device Disabled Enabled Enables or Disables Serial Port 1 Device Settings No changeable options Displays the current settings of Seria...

Страница 94: ...Setting Options Description Purpose Use This Device Disabled Enabled Enables or Disables Serial Port 2 Device Settings No changeable options Displays the current settings of Serial Port 2 Change Setti...

Страница 95: ...rt 3 Configuration Screen BIOS Setting Options Description Purpose Use This Device Disabled Enabled Enables or Disables Serial Port 3 Device Settings No changeable options Displays the current setting...

Страница 96: ...4 Configuration Screen BIOS Setting Options Description Purpose Use This Device Disabled Enabled Enables or Disables Serial Port 4 Device Settings No changeable options Displays the current settings...

Страница 97: ...5 Configuration Screen BIOS Setting Options Description Purpose Use This Device Disabled Enabled Enables or Disables Serial Port 5 Device Settings No changeable options Displays the current settings o...

Страница 98: ...s Description Purpose Use This Device Disabled Enabled Enables or Disables Serial Port 6 Note When BIOS item Network is set to Legacy it ll be automatically set to Disabled Device Settings No changeab...

Страница 99: ...abled Enables or Disables Parallel Port Device Settings No changeable options Displays the current settings of Parallel Port Change Settings Auto IO 378h IRQ 5 IO 378h IRQ 5 6 7 9 10 11 12 IO 278h IRQ...

Страница 100: ...em such as CPU temperature system temperature CPU fan speed system fan speed and voltage levels in supply Hardware Monitor Screen BIOS Setting Options Description Purpose Smart Fan Mode Configuration...

Страница 101: ...el of the VSB5V in supply VCC5V No changeable options Detects and displays the voltage level of the VCC5V in supply VCC12 No changeable options Detects and displays the voltage level of the VCC12 in s...

Страница 102: ...Fan Smart Fan Control Manual Duty Mode Auto Duty Cycle Mode Smart Fan Mode select for CPU Fan Manual Duty Mode Numeric from 1 to 100 Manual mode fan control user can write expected duty cycle PWM fan...

Страница 103: ...d enable the F81866 watchdog function to trigger a system reset via the 255 level watchdog timer F81866 Watchdog Screen BIOS Setting Options Description Purpose Enable WatchDog Enabled Disabled Enable...

Страница 104: ...the system to wake up at a preset time of a day from S5 State using RTC alarm S5 RTC Wake Settings Screen Disabled BIOS Setting Options Description Purpose Wake system from S5 Disabled Fixed Time Dyn...

Страница 105: ...enabling scheduled S5 to S0 option enabled Fixed Time System will wake on the hr min sec specified Dynamic Time System will wake on the current time Increase minute s Wake up hour Multiple options ran...

Страница 106: ...ption Purpose Wake system from S5 Disabled Fixed Time Dynamic Time Allows enabling scheduled S5 to S0 option enabled Fixed Time System will wake on the hr min sec specified Dynamic Time System will wa...

Страница 107: ...prior to booting the operating system on the local hard drive A PXE enabled workstation connects its NIC to the LAN via a jumper which keeps the workstation connected to the network even when the powe...

Страница 108: ...count Numeric from 1 to 50 Number of times that the media presence will be checked 5 4 11 Advanced USB Configuration Menu Path Advanced USB Configuration The USB Configuration allows users to configu...

Страница 109: ...This menu allows users to configure advanced Chipset settings such as System Agent SA and PCH IO configuration parameters Chipset Screen BIOS Setting Options Description Purpose System Agent SA Param...

Страница 110: ...reen BIOS Setting Options Description Purpose SA PCIe Code Version No changeable options Displays the SA PCIe Code Version VT d No changeable options VT d capability Memory Configuration Sub menu Memo...

Страница 111: ...ble options Displays the Memory RC Version Memory Frequency No changeable options Displays the Frequency of Memory Memory Timings tCL tRCD tRP tRAS No changeable options Displays the Memory Timings DI...

Страница 112: ...guration Graphics Configuration Menu Path Chipset System Agent SA Configuration Graphics Configuration The Graphics Configuration allows users to configure the display settings for the LCD panel Graph...

Страница 113: ...guration Graphics Configuration LCD Control The LCD Control allows users to select the primary and secondary display device LCD Control Screen BIOS Setting Options Description Purpose Primary IGFX Boo...

Страница 114: ...the PEG status enable Root Port configure PCI E1 maximum speed etc PEG Port Configuration Screen BIOS Setting Options Description Purpose PCI E1 No changeable options PCI E1 Link and Speed informatio...

Страница 115: ...AN function and determine the power on off state that the system will go to following a power failure G3 state PCH IO Configuration Screen BIOS Setting Options Description Purpose Name No changeable o...

Страница 116: ...tem will go to when the power is re applied following a power failure G3 state PCH IO Configuration PCI Express Configuration Menu Path Chipset PCH IO Configuration PCI Express Configuration PCI Expre...

Страница 117: ...iption Purpose Mini PCI Express Port Disabled Enabled Controls the PCI Express Root Port ASPM Disabled L0s L1 L0sL1 Auto Sets the ASPM Active State Power Management Level The option allows users to se...

Страница 118: ...ess Configuration Mini PCI Express Port Configuration Menu Path Chipset PCH IO Configuration PCI Express Configuration Mini PCI Express Port Configuration Mini PCI Express Port Configuration Screen BI...

Страница 119: ...es Disabled L1 1 L1 2 L1 1 L1 2 PCI Express L1 Substates settings Hot Plug Disabled Enabled Enables or Disables PCI Express Hot Plug PCIe Speed Auto Gen1 Gen2 Gen3 Selects PCI Express port speed Detec...

Страница 120: ...strator password you will prevent other users from changing your BIOS settings You can configure an Administrator password and then configure a user password An administrator has much more privileges...

Страница 121: ...ministrator or User Password 1 Select the Administrator Password User Password option from the Security menu and press Enter and the password dialog entry box appears 2 Select the Administrator Passwo...

Страница 122: ...g the boot order from the available bootable device s and CSM configuration Boot Screen BIOS Setting Options Description Purpose Setup Prompt Timeout Numeric from 1 to 65535 Number of seconds to wait...

Страница 123: ...Boot CSM Configuration The CSM Configuration provides advanced CSM Compatibility Support Module configurations such as Enable Disable CSM Support configure Option ROM execution boot option filter etc...

Страница 124: ...XE OpROM Note In Legacy PXE OpROM it ll automatically set Serial Port 6 to Disabled Storage Do not launch UEFI Legacy Controls the execution of UEFI and Legacy Storage OpROM Video Do not launch UEFI L...

Страница 125: ...changes and then exit the system Select Save Changes and Reset to validate the changed BIOS settings and then restart the system Discard Changed BIOS Settings To cancel the BIOS settings you have pre...

Страница 126: ...o changeable options Resets without saving any changes made in BIOS settings Save Changes No changeable options Saves Changes done so far to any of the setup options Discard Changes No changeable opti...

Страница 127: ...hnical Summary This appendix will give you a brief introduction of the allocation maps for BA 2501 resources The following topics are included BA 2501 Block Diagram Interrupt Map I O Map Memory Map DM...

Страница 128: ...V GIGA LAN1 INTEL MAGJACK PCI E 1X BUS INTEL I211 GIGA LAN2 PCI E 1X BUS XDP UDIMM DRAM Modules DDR4 1866 2133 MHz UDIMM DRAM Modules DDR4 1866 2133 MHz UDIMM DRAM Modules DDR4 1866 2133 MHz Digital D...

Страница 129: ...ice IRQ 13 Numeric data processor IRQ 14 Motherboard resources IRQ 16 Intel R Serial IO I2C Host Controller A160 IRQ 16 High Definition Audio Controller IRQ 16 Standard AHCI 1 0 Serial ATA Controller...

Страница 130: ...99 Microsoft ACPI Compliant System IRQ 100 Microsoft ACPI Compliant System IRQ 101 Microsoft ACPI Compliant System IRQ 102 Microsoft ACPI Compliant System IRQ 103 Microsoft ACPI Compliant System IRQ 1...

Страница 131: ...IRQ 125 Microsoft ACPI Compliant System IRQ 126 Microsoft ACPI Compliant System IRQ 127 Microsoft ACPI Compliant System IRQ 128 Microsoft ACPI Compliant System IRQ 129 Microsoft ACPI Compliant System...

Страница 132: ...IRQ 151 Microsoft ACPI Compliant System IRQ 152 Microsoft ACPI Compliant System IRQ 153 Microsoft ACPI Compliant System IRQ 154 Microsoft ACPI Compliant System IRQ 155 Microsoft ACPI Compliant System...

Страница 133: ...mpliant System IRQ 178 Microsoft ACPI Compliant System IRQ 179 Microsoft ACPI Compliant System IRQ 180 Microsoft ACPI Compliant System IRQ 181 Microsoft ACPI Compliant System IRQ 182 Microsoft ACPI Co...

Страница 134: ...ssignment 0x00000000 0x00000CF7 PCI bus 0x00000020 0x00000021 Programmable interrupt controller 0x00000024 0x00000025 Programmable interrupt controller 0x00000028 0x00000029 Programmable interrupt con...

Страница 135: ...pt controller 0x000000AC 0x000000AD Programmable interrupt controller 0x000000B0 0x000000B1 Programmable interrupt controller 0x000000B2 0x000000B3 Motherboard resources 0x000000B4 0x000000B5 Programm...

Страница 136: ...54 0x00001857 Motherboard resources 0x0000E000 0x0000EFFF Intel R 100 Series C230 Series Chipset Family PCI Express Root Port 9 A118 0x0000F000 0x0000F03F Intel R HD Graphics 530 0x0000F040 0x0000F05F...

Страница 137: ...Motherboard resources 0xDFFE0000 0xDFFFFFFF Motherboard resources 0xFDAF0000 0xFDAFFFFF Motherboard resources 0xFDAE0000 0xFDAEFFFF Motherboard resources 0xFDAC0000 0xFDACFFFF Motherboard resources 0...

Страница 138: ...E40EFFF Intel R Serial IO I2C Host Controller A160 0xFED40000 0xFED44FFF Trusted Platform Module 1 2 0xDF14D000 0xDF14DFFF Intel R Active Management Technology SOL COM7 0xDF020000 0xDF023FFF Intel R I...

Страница 139: ...2501 SERIES USER MANUAL Page A 13 Memory Map Assignment 0xDF120000 0xDF12FFFF High Definition Audio Controller 0xA0000 0xBFFFF PCI bus 0xA0000 0xBFFFF Intel R HD Graphics 530 DMA Map DMA Map Assignme...

Страница 140: ...re the configuration registers The chip selects the Logical Device and activates the desired Logical Devices through Extended Function Index Register EFIR and Extended Function Data Register EFDR The...

Страница 141: ...al 07h out dx al inc dx mov al 07h out dx al Enable Watch dog feature mov al 030h out dx al inc dx mov al 01h out dx al Set timeout interval as 30 seconds dec dx mov al 0F6h out dx al inc dx mov al 1...

Страница 142: ...exe v5 09 01 into the storage device The utility and BIOS file should be saved to the same path 4 Make sure the target system can first boot to the EFI shell environment 1 Connect the USB storage devi...

Страница 143: ...R MANUAL Page A 17 6 Press ESC or DEL to enter into BIOS setup menu again 7 Select Boot menu and set UEFI Built in EFI Shell as the 1st boot device 8 Press F4 key to save the configuration and restart...

Страница 144: ...I firmware update utility the command line is shown as below AFUEFIx64 ROM File Name option1 option2 Users can type AFUEFIx64 to view the definition of each control option The recommended options for...

Страница 145: ...e g W2 3 During the update procedure you will see the BIOS update process status and its execution percentage Beware Do not turn off the system power or reset your computer if the whole procedure are...

Страница 146: ...Appendix A Technical Summary BA 2501 SERIES USER MANUAL Page A 20 7 Reboot the system and verify if the BIOS version shown on the initialization screen has been updated...

Отзывы: