ProTalk PT-Door01 Скачать руководство пользователя страница 4

4            

 

 TECHNICAL

 

    PARAMETERS

 

                                                                                                      

 

    32

   

4.1

Electrical parameters

 32

4.2

Mechanical parameters

 32

4.3

Video parameters

32

4

 | 

P a g e

Содержание PT-Door01

Страница 1: ...ProTalk Door Entry System PT Door01 PT Door01C PT Door02 PT Door02C PT Door01CAV 1 P a g e...

Страница 2: ...d aluminium The unit is powered by either an AC DC 12V power supply which can also power an electric door lock or via a Power over Ethernet PoE system The basic ProTalk Door Entry system includes an o...

Страница 3: ...in the building 15 2 3 1 Outbound call 15 2 3 2 Incoming call 15 3 PARAMETER PROGRAMMING 16 3 1 Basic VoIP settings 16 3 1 1 Choice of mode and sign in 16 3 1 2 Language setting 17 3 1 3 Network setti...

Страница 4: ...4 TECHNICAL PARAMETERS 32 4 1 Electrical parameters 32 4 2 Mechanical parameters 32 4 3 Video parameters 32 4 P a g e...

Страница 5: ...to connect to the door phone 12v power supplies with battery backup option Exit Relays or Bundles of above as complete door entry kits 1 2 Terminology Ethernet is a family of frame based computer net...

Страница 6: ...mages Voice over Internet Protocol VoIP is a general term for a family of transmission technologies for delivery of voice communications over IP networks such as the Internet The Internet Protocol Sui...

Страница 7: ...consist of a motherboard an IP module a PoE module and a camera see picture 1 for the setting and positioning of the modules We recommend that the system is powered by PoE technology Alternating Curre...

Страница 8: ...ystem to accommodate this please see picture 4 Picture 1 Motherboard The connection of relay contact terminals is illustrated on picture 2 The NO annotation means an idle disconnected contact COM mean...

Страница 9: ...Picture 2 Connection of the Door Entry System 9 P a g e...

Страница 10: ...mechanism max 350mA Voice Communication Setting Volume settings have been preset by the manufacturer The preset position is shown on picture 5 If changes are required these can easily be made by using...

Страница 11: ...l and automatically switches off at the end DIP relay setting of base parameters and mode with DIP relay Reserve 1 Change of mode P2P SIP server 2 Basic setting deletes all parameters and changes them...

Страница 12: ...1 5 2 Name Tag Back Lighting Disassembly 1 5 3 Wall Mounting The unit can be Wall mounted with the enclosed screws and wall plugs screw driver diameter 5mm 12 P a g e...

Страница 13: ...gs after wall mounting 1 5 5 Name Tag Change Each button has a card tag held in place with a plastic cover see picture above Paper name tags of the correct size can be produced in an Excel worksheet i...

Страница 14: ...e number dialled by the system will depend on the mode set on the system Mode Day Night if the system is in DAY mode it will always dials the number set in the first column and in NIGHT mode it will a...

Страница 15: ...e modes m 1 to m 5 Day Night mode hang up etc 10 seconds into any conversation the system will issue an end of call alert by choosing it is possible to prolong the call the call will then be ended by...

Страница 16: ...the System After restarting the System return relay 4 to the on position There are two options to restart the System either by disconnecting the power supply or by clicking on restart in the WEB inter...

Страница 17: ...The factory set user name is always admin and the password is 1234 these can be changed in the settings Picture 9 Log in to set up 3 1 2 Language Setting The language is set in the bottom part of menu...

Страница 18: ...ignment 3 IP address setting mask setting or any other network setting If you are unsure please contact your network administrator 4 Display of System in current mode Day Night 5 Return to main page w...

Страница 19: ...m restart screen will come up see page 26 Important If you are using a DHCP setting the address will be assigned automatically and your network administrator will be able to identify the actual IP add...

Страница 20: ...to session progress added for some SIP proxy servers that require this 2 Symmetric RTP added for some SIP proxy servers that require this and 3 Default values will perform basic factory reset After m...

Страница 21: ...re registration 4 Choice of signal of incoming call Ringing can be changed to Session progress added for some SIP proxy servers that require this 5 Symmetric RTP added for some SIP proxy servers that...

Страница 22: ...he streaming video can be viewed on a telephone Grandstream series GXW3000 which is equipped with a large LCD display Another interesting way to view the video is via the installed Pop Up program UDVg...

Страница 23: ...e shown in the header of Pop Up program Video parameters are explained on page 32 3 1 8 Day Intervals Only displays if the automatic Day Night relay is ticked on the basic parameters page Available on...

Страница 24: ...switch it back on for security purposes 2 Video on off relay when in VoIP call some systems cannot work with both at once 3 Opportunity to change usual TCP port 80 4 Opportunity to switch on off acces...

Страница 25: ...nhanced log and vice versa 2 Click on Download log file and you can save a file to your chosen position This file will have the ending bin which must be changed to tar To open an archived tar file use...

Страница 26: ...ts logos etc 8 Upload language uploads or rewrites language support files It is not possible to edit the two basic languages Czech and English 9 Save configuration all files 10 Restore configuration r...

Страница 27: ...ting the name use the program PSPad Only translate the terms in quotation marks and ensure that notations are kept in the HTML format 3 2 Door Entry System parameter setting 3 2 1 Basic Parameters 1 D...

Страница 28: ...changes the functions of the System 3 2 2 All about Relays 1 Relay modes 1 Switch mode switches on by either command or password for a given time set in relay closing used for electric locks gate ope...

Страница 29: ...When choosing the password it is necessary to adhere to the following rules Choose a password in such a way that it is not possible to deduct the combination from worn buttons The first character of...

Страница 30: ...ger than the set time the code will not be evaluated correctly Dialling if the button pressed is the same as first character the password for switch on the option will be delayed for this length of ti...

Страница 31: ...ephone numbers in column 2 Night Mode can be as long as 16 digits If P2P mode is in use then the IP address will need to be saved in the following format 192 168 1 231 where means If the SIP server mo...

Страница 32: ...starts running properly These browsers are preferable to Internet Explorer because the video viewing is smoother and has less impact on the network load Streaming video for IP phones H 263 formatting...

Страница 33: ...nt 1 4 pictures second is set in Video setting on the WEB The picture count of both MJPG and Stream H 263 is set by the camera type used however this is normally between 7 12 pictures second Ports Por...

Страница 34: ...arranty claims are handled through your dealer Warranty claims should be accompanied by The product in question a description of the problem proof of purchase and your full name and address The warran...