PAGE 34
PROGRAMMING EXAMPLES
B1290:
Dial Format is 0
YOU:
Next
B1290:
Squelch is 0
YOU:
Enter busy when high
B1290:
Squelch is 1
YOU:
Next
B1290:
Relay Voice is On
At this point you are finished programming and may hang up the telephone. The directory is programmed with the
voice message repeated three times on the radio and then once on the phone line. Another method of programming
the radio announcement would be to have an alert tone followed by the message repeated twice. In this case the
entry for each of the radio related commands would be:
B1290:
Directory A, Line One is...
YOU:
[RADIO][ALERT] [VOICE][VOICE]
B1290:
Directory A, Line One is RADIO ALERT VOICE VOICE
Over the telephone, the message will be repeated only once.
If this programming is used, when the B1290 registers an alarm, the reporting cycle will be as follows:
Over radio:
Alert tone
Ajax Compressor Station; Power Failure
Ajax Compressor Station; Power Failure
Enter Acknowledge Code
pause for 2 minutes
Alert tone
Ajax Compressor Station; Power Failure
Ajax Compressor Station; Power Failure
Enter Acknowledge Code
pause for 2 minutes
Alert tone
Ajax Compressor Station; Power Failure
Ajax Compressor Station; Power Failure
Enter Acknowledge Code
pause for 2 minutes
Over telephone: Dial 4032559544
Ajax Compressor Station; Power Failure
Enter Acknowledge Code
pause for 5 seconds -waiting for acknowledge code
Ajax Compressor Station; Power Failure
Enter Acknowledge Code
pause for 5 seconds -waiting for acknowledge code
This sequence repeats for 60 seconds.
If the Acknowledge Code is not received over the telephone, the B1290 will wait ten minutes and try the complete
sequence again, starting with the radio cycle. If no Acknowledge Code is received after six tries at ten minute
intervals, the B1290 will switch to reporting every hour until the alarm is acknowledged.
Example 2: Dialing from Two Different Telephone Directories
In this example, the B1290 is programmed to telephone whoever is on call if there is an alarm. The company has
two groups of employees who take turns being on call. Instead of reprogramming the B1290 directory every week,
Содержание Plus B1290
Страница 1: ...Installation Operation Manual January 2022 Rev 2 04 ...
Страница 4: ......
Страница 19: ...OPERATION PAGE 15 ...
Страница 49: ...PROGRAMMING EXAMPLES PAGE 45 etc ...
Страница 60: ...PAGE 56 APPENDIX C PROGRAMMMING TREE Next ...
Страница 61: ...APPENDIX D MOUNTING PAGE 57 15 APPENDIX D MOUNTING Figure 9 Mounting Detail ...