RLX2-IFHxE ♦ Industrial Wireless
Diagnostics and Troubleshooting
Industrial Frequency Hopping Ethernet Radios
User Manual
ProSoft Technology, Inc.
Page 53 of 81
January 27, 2014
Select Radio
: Opens the
Radio Discovery Tool
dialog box . Choose a radio
from the list, and then click
OK
to select the radio.
Open
: Click to begin testing the radio.
Close
: Click to quit testing the radio and close the dialog box.
Noise Level graphs
: The green plot represents the current spectrum
values. The red plot represents the maximum value of the green plot over
time. The yellow line represents the lowest current value or the current noise
floor. Each point represents one of the available frequencies on which the
radio could hop.
Hold
: Click to freeze the peak value graph.
Clear
: Click to reset the peak value graph.
Show Mean Value
: Displays the average value of the multiple
measurements taken on each channel during a scan period.
Show Max Value
: Displays the maximum value of the multiple
measurements taken on each channel during a scan period.
3.4
Troubleshooting ControlScape FH Error Messages
ControlScape FH displays informative error messages for many types of
communication problems. The following topics describe how to interpret these
messages.
3.4.1 Radio Configuration Status Dialog Box
The
Radio Configuration Status
dialog box opens when you attempt to
communicate with a radio network in
Diagnostic
mode, and ControlScape FH is
not able to connect with any radios on the network.
Click
Retry
to attempt an automatic baud rate detection sequence.
Click
Cancel
to stop attempting to connect to a radio.
3.4.2 Invalid Password Dialog Box
The Invalid Password dialog box opens when you enter the network password
incorrectly. Check the status of the
Caps Lock
key on your keyboard, and then
try entering the password again.
OK:
Click
OK
to save your selection and close the dialog box.
Help:
Click
Help
to read the online help for ControlScape FH.
3.4.3 Check the Ethernet cable
If you connect a radio to a PC or network using an Ethernet cable and the
Ethernet LED does not light on the radio, you may have used the wrong cable
type. In other words, you may have used a crossover cable when you should
have used a straight-through cable, or vice versa.
Use a straight-through cable when connecting the radio to an Ethernet hub or
a 10/100 Base-T Ethernet switch. Straight-through cables are used in most
cases.
Содержание RLX2-IFH24E