ProSoft RadioLinx RLXIB-IHW Скачать руководство пользователя страница 4

 

 

IMPORTANT: 

This device is a 2.4-GHz, low-power RF device intended for office and home use in all EU and EFTA 

member states, except in France where restrictive use applies. 

EU Requirements 

1. For outdoor use, France has a frequency restriction of 2.4GHz - 2.454GHz for an output power greater than 10mW 
and below 100mW. 
2. For outdoor use in France, the output power is restricted to 10mW in the frequency range of 2.454GHz – 
2.4835GHz. 
3. 5.15GHz – 5.35GHz is restricted to 200mW EIRP throughout the European Union.  

RLXIB: Power over Ethernet Injector and Accessories "Warning" 

The PoE Injector was not a part of the hazardous location or ATEX certification. Therefore, if an injector is used to 
power any of the radios, the PoE injector must be installed/located outside of any area that could be known to be 
hazardous. The AC power adaptor was not a part of the haz loc certification. 

The RLXIB series were tested and certified to hazardous location and ATEX without any accessories included in this 
certification. Therefore, any accessory added to the RLXIB series radios must be used in an area known to be non-
hazardous as they have not been subjected to hazardous location and ATEX certifications.  

The preferred method of powering the radios is using the supplied power adaptor but If the PoE injector is used in an 
ordinary location "only", the PoE injector must be Listed. If the PoE injector is used instead of the supplied power 
adaptor, all of the wiring to and from the injector must be routed/installed inside building/plant  and never 
routed/installed outside of the building/plant.  

Your Feedback Please 

We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, 
compliments or complaints about the product, documentation, or support, please write or call us.  

ProSoft Technology

 

5201 Truxtun Ave., 3rd Floor 
Bakersfield, CA 93309 
+1 (661) 716-5100 
+1 (661) 716-5101 (Fax) 
www.prosoft-technology.com 
[email protected] 

Copyright © ProSoft Technology, Inc. 2009. All Rights Reserved. 

RLXIB-IHW Setup Guide 
September 16, 2009 

ProSoft Technology 

®

, ProLinx 

®

, inRAx 

®

, ProTalk

®

, and RadioLinx 

®

 are Registered Trademarks of ProSoft 

Technology, Inc. All other brand or product names are or may be trademarks of, and are used to identify products 
and services of, their respective owners.  

ProSoft Technology

®

 Product Documentation 

In an effort to conserve paper, ProSoft Technology no longer includes printed manuals with our product shipments. 
User Manuals, Datasheets, Sample Ladder Files, and Configuration Files are provided on the enclosed CD-ROM, 
and are available at no charge from our web site: www.prosoft-technology.com 

Printed documentation is available for purchase. Contact ProSoft Technology for pricing and availability. 

North America: +1.661.716.5100 
Asia Pacific: +603.7724.2080 
Europe, Middle East, Africa: +33 (0) 5.3436.87.20 
Latin America: +1.281.298.9109 

 

Содержание RadioLinx RLXIB-IHW

Страница 1: ...RLXIB IHW 802 11a b g RadioLinx 802 11abg Industrial Hotspot with POE and Serial Server September 16 2009 SETUP GUIDE...

Страница 2: ...a minimum distance of 1 mW cm2 power density from the user or 20 cm whichever is greater If a specific application requires proximity of less than 20 cm the application must be approved through the FC...

Страница 3: ...aving jurisdiction A Warning Explosion Hazard Do not make or break connections in an explosive atmosphere B Caution Use only approved recommended power supply C Warning Power supply should be installe...

Страница 4: ...jector must be Listed If the PoE injector is used instead of the supplied power adaptor all of the wiring to and from the injector must be routed installed inside building plant and never routed insta...

Страница 5: ...RLXIB Power over Ethernet Injector and Accessories Warning 4 Your Feedback Please 4 ProSoft Technology Product Documentation 4 1 Before You Begin 7 1 1 Install the IH Browser Configuration Tool 8 1 2...

Страница 6: ...RLXIB IHW 802 11a b g Contents RadioLinx 802 11abg Industrial Hotspot with POE and Serial Server Setup Guide Page 6 of 19 ProSoft Technology Inc September 16 2009...

Страница 7: ...Radio RLXIB IHW RadioLinx 802 11abg Industrial Hotspot with POE and Serial Server 1 Cable Cable 15 RS232 6 foot RS232 null serial cable 1 Cable RL CBL025 5 foot Ethernet Straight Thru Cable 1 Antenna...

Страница 8: ...rive where you inserted the ProSoft Solutions CD d Select the file prosoft exe and then click Open e On the Run dialog box click OK 2 On the CD ROM menu select IH Browser for the RLX IHx and RLXIB x P...

Страница 9: ...number of the radio this number is also printed on the side of the radio If a radio listing does not appear in the window select Scan from the File menu If you still do not see a radio listing see Tro...

Страница 10: ...hernet LED should also be green meaning that the Ethernet connection is working The RF Transmit and RF Receive LEDs should blink For information on making connections see Radio Power Requirements and...

Страница 11: ...on Diagnostic Utility to assign a permanent IP address To assign a temporary IP Address 1 In IH Browser click to select the radio Tip If a radio listing does not appear in the window open the File men...

Страница 12: ...aster radio make the following changes to the web configuration form Radio Network Settings Radio Name Enter a unique name for the radio Select Master as the radio mode Network SSID Assign a network n...

Страница 13: ...ters The default pass phrase is passphrase lower case no quotes For more information on encryption see Security settings Because you must assign the same Network SSID and WPA phrase to the repeater ra...

Страница 14: ...nd restart the radio Note To discard your changes and start over click Cancel Changes 1 8 Adding and Configuring Additional Radios At this point you should attach and configure any additional IHW radi...

Страница 15: ...c Page 15 of 19 September 16 2009 2 Verify Communication When configured the name of each radio is preceded by an M for Master an R for Repeater or a C for Client in the IH Browser window Look at the...

Страница 16: ...RLXIB IHW 802 11a b g Verify Communication RadioLinx 802 11abg Industrial Hotspot with POE and Serial Server Setup Guide Page 16 of 19 ProSoft Technology Inc September 16 2009...

Страница 17: ...et of LEDs that indicate the radio s status LED Description Power This green LED indicates that the radio has power RF Transmit This yellow LED indicates RF transmission RF Receive This green LED indi...

Страница 18: ...adio settings You can retrieve the default password to use the software again but you will lose all the settings you programmed before To retrieve the default password and return the radio to its defa...

Страница 19: ...f 19 September 16 2009 4 What s Next Congratulations Your wireless network is up and running You now need to connect your wireless Hotspots to your network devices ProSoft Technology provides applicat...

Отзывы: