![Pro'sKit MT-7029 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/proskit/mt-7029/mt-7029_user-manual_1604812016.webp)
15
Figure 9 Coaxial Cable & Continuity Test
Validating Telephone Service and Polarity
:
Please follow the following steps to check the polarity of telephone
lines:
1. Connect the red and black alligator clip of the Transmitter to the
telephone line jack or socket or punch-down block.
2. Press
button to turn on the power, “POWER/ BAT LOW”
indicator will light up. Then press
to operate the polarity
indication feature and the LED indicator will light up. According
to the function of the phone positive/negative polarity test start.
3.
「
POL
-
/G
,
POL
+
/R
」
LED indicator is dual color (Red/ Green).
The LED indicator of the Transmitter indicates the status as
below:
• Red
light
:
Red alligator clip at positive (+) polarity
;
Black
alligator clip at negative (-) polarity.
• Green
light
:
Red alligator clip at negative (-) polarity
;
Black alligator clip at positive (+) polarity.