background image

 

10

is pressed. If the “BATTERY GOOD” LED 
does not light, replace the battery. 

6.2 Low Battery Indicator:   

When the “BATTERY LOW” LED light on, 
replace the battery.   

6.3 No connection LED/Single Beep 

If the Remote is not connected to the main 
unit with a cable, or the cable has no intake 
conductors, the “NO CONNECTION” LED 
with light and the beeper will sound once.   

6.4 Connected LED/Lo-Hi Beep /Numbered 

LEDs  

If the “CONNECTED” LED lights and the beeper 
emit a Lo-Hi beep, examine the numbered LEDs 
(i.e. LEDs numbered to 8 and the S LED). 
Corresponding to the type of cable being tested 
must light .Examine the table below the Numbered 
LEDs, noting what LEDs should light .If all of the 
LEDs do not light; the cable has an OPEN fault. If 
all of the appropriate numbered LEDs light, the 
cable is OK.   
Note:  
When testing an RJ-45 UTP cable, the S LED must 
not light. The CABLE SNIFFER-REMOTE is 
intended to test complete cables. It may not find 
faults in cables that are intentionally incomplete. 
For example, the standard EIA/TIA 568 RJ-45 
terminated Ethernet cables is expected to contain 8 
conductors. If only 4 conductors are used between 
the RJ-45 connectors. The CABLE 
SNIFFER-REMOTE may not properly identify the 
faults.  
RJ-11 cables may have 2 connections, 4 

Содержание MT-7057N

Страница 1: ...ABLE SNIFFER REMOTE MT 7057N User s Manual 1 st Edition 2016 2016 Copy Right by Prokit s Industries Co Ltd Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot co...

Страница 2: ...1 Contents INTRODUCTION 2 SAFETY and WARNING 2 PRODUCT FEATURES 5 SPECIFICATIONS 6 FRONT PANEL 6 ACCESSORIES 7 OPERATION 8 CABLE REPAIRE 12 MAINTENANCE 16...

Страница 3: ...s or reverse wired telephone cables SAFETY WARNINGS 1 Read instructions carefully before using this tester Failure operation may result in damage to the tester or injury to the users 2 Do not use this...

Страница 4: ...echnicians who know the dangers of and the safety rules applicable to this type of equipment Failure to observe this precaution may result in damage to the tester or injury to the user 7 Do not touch...

Страница 5: ...ent Condensation of water inside and outside of the tester may produce dangerous conditions Allow the tester to warm to room temperature before using 14 Do not modify this tester Changing the design m...

Страница 6: ...rom the battery could damage the tester PRODUCT FEATURES 1 Test 4 types of cables 2 Simple one button test 3 Ergonomic portable handheld design 4 Tests installed wiring or patch cables 5 Remote unit s...

Страница 7: ...lug on other end BNC cables with male connectors 2 Faults Indicated No Connection Short connected crossover 3 Low Battery Indicator LED light up to indicate low battery 4 Case Dimensions 6 3x3 4x1 0 i...

Страница 8: ...7 ACCESSORIES 1 RJ45 to BNC female connector 2 Instruction manual 3 Pouch bag...

Страница 9: ...able cannot be tested simultaneously 2 The MAIN and REMOTE unit The CABLE SNIFFER REMOTE consists of a Main unit and a Remote unit The Remote unit stores conveniently on the bottom of the Main unit It...

Страница 10: ...nit Once detached the Remote can be attached to one end a cable and the Main unit attached to the other to the other end of the cable These ends are often in different rooms and on different floors of...

Страница 11: ...LED Corresponding to the type of cable being tested must light Examine the table below the Numbered LEDs noting what LEDs should light If all of the LEDs do not light the cable has an OPEN fault If a...

Страница 12: ...Note In the SHORT mode the Numbered LEDs only indicate the location of the shorts The other Numbered LEDs are dark If more than 3 numbered LEDs light there may be multiple shorts in the cable 6 6 Cro...

Страница 13: ...sharply around a corner punctured by a nail or staple over loaded hit by lighting etc Similar abuses will damage the connectors on the ends of the cable The connectors can also be damaged by excessive...

Страница 14: ...y seldom occur as the result of a badly crimped RJ connector so the user should suspect a problem with the wire possibly a staple or mail through the wire or a crushed or pinched wire if the 4 in 1 in...

Страница 15: ...ired straight through Crossover cables used on LANs are purposely mis wired with their Receive and Transmit wires cross over The CABLE SNIFFER REMOTE will test this as a bad cable but it may work just...

Страница 16: ...cross talk A short cable 10ft or less that is improperly paired may work just fine However longer cables paired in exactly the same way may not work This explains why an installer can make short jump...

Страница 17: ...and the answering machine may not answer when the line rings MAINTENANCE Your CABLE SNIFFER REMOTE is a precision test instrument and when used as described in this manual should not require maintenan...