ProsKit MT-1233C Скачать руководство пользователя страница 3

Table 1. International Electrical Symbols 

 AC 

(Alternating 

Current) 

 DC 

(Direct 

Current) 

 

AC or DC 

 

Battery 

 

Safety information* Refer to the manual 

 

Earth ground 

  Fuse 

 

Conforms to European Union directive 

 

Double insulated 

 

WARNING AND PRECAUTIONS 

To avoid possible electric shock or personal injury, 
and to avoid possible damage to the meter or to the 
equipment under test, comply with the following 
practices: 

 Do not use the meter if it is damaged. Before you 

use the meter, inspect the case. Pay particular 
attention to the insulation surrounding the 
connectors. 

 

3

 Inspect the test leads for damaged insulation or 

Содержание MT-1233C

Страница 1: ...MT 1233C MT 1233D 3 1 2 Digital Multimeter User s Manual 1 st Edition 2013 2013 Copyright by Prokit s Industries Co Ltd 1...

Страница 2: ...0V overvoltage standards See specifications Use the Meter only as specified in this manual otherwise the protection provided by the Meter may be impaired In this manual a Warming identifies conditions...

Страница 3: ...e insulated WARNING AND PRECAUTIONS To avoid possible electric shock or personal injury and to avoid possible damage to the meter or to the equipment under test comply with the following practices Do...

Страница 4: ...nnecting the meter in the circuit When servicing the meter use only specified replacement parts Do not use the Meter in a manner not specified by this manual or the safety features of the meter may be...

Страница 5: ...g electric circuits or a copy machine CAT II From equipment supplied from the fixed installation e g TVs PCs portable tools and household appliances CAT III From equipment in fixed equipment installa...

Страница 6: ...DATA HOLD button 3 BACK LIGHT button 4 FUNCTION AND RANGE SWITCH This switch is used to select the function and desired range as well as to turn on the instrument To extend the life of this battery t...

Страница 7: ...0 3d OVERLOAD PROTECTION 220V rms AC for 200mV range and 500V DC or 500V rms for all ranges AC VOLTAGE Range Resolution Accuracy 200V 100mV 500V 1V 1 2 5d RESPONSE Average responding calibrated in rm...

Страница 8: ...DROP 200mV AUDIBLE CONTINUITY RANGE DESCRIPTION Built in buzzer sounds if resistance is less then 30 20 OVERLOAD PROTECTION 5 second maximum 220V rms WARNING DO NOT input any voltage at this range for...

Страница 9: ...10d MAXIMUM OPEN CIRCUIT VOLTAGE 2 3V OVERLOAD PROTECTION 5 seconds maximum 220Vrms WARNING DO NOT input any voltage at resistance range for safety TEMPERATURE MT 1233C only RANGE RESOLUTION ACCURACY...

Страница 10: ...r when measuring resistance or continuity in a circuit make sure the power to the circuit is turned off and all capacitors are discharged DC AC VOLTAGE MEASUREMENT 1 Connect red test lead to V mA jack...

Страница 11: ...n is designed for intermittent use only Maximum contact time of the test leads with the circuit is 15 seconds with a minimum intermission time of seconds between tests RESISTANCE MEASUREMENT 1 Red lea...

Страница 12: ...to V mA and COM jacks 2 RANGE switch to TEMP position 3 The display will read Temperature value AUDIBLE CONTINUITY TEST 1 Red lead to V mA Black lead to COM 2 RANGE switch to position 3 Connect test...

Страница 13: ...c Soak a new swab with isopropyl and work around the inside of each input terminal d Use a new swab to apply a light coat of fine machine oil to the inside of each terminal FUSES TEST Warning To avoi...

Страница 14: ...ed by 1 5V battery AAAx2 Snap the battery connector leads to the terminals of a new battery and reinsert the battery into the case top Dress the battery leads so that they will not be pinched between...

Страница 15: ...15 SERVICE AND PARTS If the Meter fails check the batteries and fuses first and then review this manual to make sure that you are operating the Meter correctly...

Страница 16: ...16 MT 1233C D 3 1 2 1 1 2 1 3 MT 1233C 1 MT 1233C D IEC61010 CAT I 600V CAT II 300V 2...

Страница 17: ...1 2 3 500V 4 60V 42V rms 5 6 7 8 10A 9 10 11 12 17...

Страница 18: ...13 AC DC AC DC 500Vrms 10A mA F200mA 250V 1999 3 1 H 18 l 5V AAA x2...

Страница 19: ...0 40 32 104 10 50 C 14 122 130L 72W 28 H 130 1 2 3 4 5 6 10A 7 1 HOLD 2 10 19...

Страница 20: ...1 a V mA COM b c 500V 1 10M 10K 0 1 2 a V mA l0A COM b c mA 5 20mm F200mA 250V 10A 10 15 20...

Страница 21: ...3 a V mA COM b c 200 0 5 4 a V mA COM b c d 50 PN 21...

Страница 22: ...0 6V 1 5 MT 1233C a V mA COM b c K 250 60V 30V 6 MT 1233D V mA COM 50Hz 1M 3V 10V 22...

Страница 23: ...23 a 1 23 5 75 1 MT 1233C MT 1233D 200mV 100uV 2000mV 1mV 20V 10mV 200V 100mV 0 8 3d 500V 1V 1 0 3d 10M 200mV 250V 500V 2 MT 1233C MT 1233D 200V 100mV 500V 1V 1 2 5d 5M 40Hz 400Hz 500V...

Страница 24: ...1233C MT 1233D 2000uA 1uA 20mA 10uA 200mA 100uA 1 2 5d 10A 10mA 2 5 5d F200mA 250v 10A 10 I5 4 MT 1233C MT 1233D 200 0 1 1 5 5d 2000 1 20 K 10 200K 100 1 0 3d 20M 10K 1 0 5d 200M 100K 1 0 10d 10d 2 3...

Страница 25: ...5 MT 1233C 40 150 1 0 3d 150 1000 1 1 5 15d 40 302 1 0 4d 302 1832 1 1 5 15d K 6 MT 1233D 50Hz 50K 7 50 25...

Страница 26: ...1 OFF 2 3 AAA 1 5 2 4 26...

Страница 27: ...27...

Страница 28: ...28...

Отзывы: