Temperature Calibration Set
The soldering iron should be recalibrated after changing the iron, or
replacing the heating element or tip.
1
In the function setting menu, move cursor to the “Cal. Status.” mode
then press the knob. Move cursor to the ”Real Temp” , input the real
temperature, move cursor to the “OK” (see fig 3) then press knob confirm
it. Press knob to the next menu, choose the “Save & Exit” save the
temperature and exit menu.
Fig.3 Fig.4
2. Calibrating the iron temperature
Setting the soldering iron station temperature to 350
℃
, when the
temperature stabilizes, use s
oldering iron tip thermometer measurement
and record tip real temperature
, follow the procedure
1
input real
temperature (see Fig.4), soldering iron station will calculate temperature.
3 Cal. Status description
3.1.
When Cal. status display “----“(see Fig 5)
,
it means temperature
have not calibration.
Fig.5 Fig.6
3.2.
When Cal. status display “>>>>” (see Fig 6.)
,
it means “Real Temp.”
has calibrated and increase temperature.
For example :“set.Temp”is 350
℃
, "Real Temp.”is 320
℃
, after temperature
calibration as Fig 4.,temperature will rise to 350
℃
.
3.3.
When Cal. status display “<<<<” (see Fig 7.)
,
it means “Real Temp.”
has calibrated and decrease temperature.
3.4.
When Cal. status display “
》
》
》
” (see Fig 8.)
,
it means “Real Temp.” has
calibrated to max. temperature, can not increase anymore, but it can
decrease temperature.
Fig.7 Fig.8
3.5
When Cal. status display “
《
《
《
” (see Fig 9.)
,
it means “Real Temp.” has
calibrated to minimum temperature, can not decrease anymore, but it can
increase temperature.
Fig.9
Auto sleep mode setting
1
In the function setting menu, move cursor to the “Sleep Temp.” mode,
press knob to the setting, temperature range is 30~400
℃
(86~752
℉
),
after setting, press knob to the next menu, choose the “Save & Exit”
save the temperature and exit the menu.
2
In the function setting menu, move cursor to the ”Sleep Timer” mode,
press knob to the setting, sleep timer is adjustable from 1~360 minutes
or setting “OFF” stop sleep mode activate, after setting, press knob to
the next menu, choose the “Save & Exit” save the setting and exit the
menu.
Fig. 10
Fahrenheit and Centigrade Selecti
the “Unit” mode
,
press knob to
menu, move cursor to the “Be
to the
e error code appears, it will have di-di-di alarm sound.
de, press
ob
adjustment screen brightness,
menu, move cursor to the “Contrast” mode, press
knob
adjustment screen contrast,
ing menu, move cursor to the “Passcode” mode
,
g(see Fig 11), input the old code and
he
enu, other function was locked.
e,
setting.
.1
5. Af
s
.
on
In the function setting menu, move cursor to
the setting, rotate around the
knob
, select “Fahrenheit” or “Centigrade” unit,
press knob to the next menu, choose the “Save & Exit” save the setting
and exit the menu.
Beep setting
In the function setting
ep ”, press knob
setting, rotate around the
knob
, switch “ON” or “OFF” mode, press knob to
the next menu, choose the “Save & Exit” save the setting and exit the
menu.
When beep is setting “ON” mode, press knob will have key beep.
When th
LCD screen brightness adjustment
In the function setting menu, move cursor to the “Brightness” mo
knob to the setting, rotate around the
kn
press knob to the next menu, choose the “Save & Exit” save the setting
and exit the menu.
LCD screen contrast adjustment
In the function setting
knob to the setting, rotate around the
press knob to the next menu, choose the “Save & Exit” save the setting
and exit the menu.
Temperature passcode setting
1. In the function sett
press knob into the passcode settin
new code, press knob to the next menu, choose the “Save & Exit” save t
setting and exit the menu.
2. After passcode set, only temperature memory CH1/CH2/CH3 can be
choose in the main m
3. In the main menu, press 3 seconds of shuffle knob, input the passcod
into the function setting menu, now can start to do any
4. Cancel passcode : In the main menu, press 3 seconds of shuffle knob,
input the passcode, into the function setting menu, follow the 12
procedure, set new code “000” .
ter setting, press knob to the next menu, choose the “Save & Exit”
ave the setting and exit the menu
CAUTION:
Factory initial setting is “000”, this code without lock
function.
Fig11 pass code setting Input old code error
Change pass code successful
have not input new code
Input different new code
Reset
In the function setting
eset” mode
,
initial
s “NO” (see Fig12) rotate around the
knob
, choose “YES” (see
the
menu, move cursor to the “R
setting i
,
Fig 13) and press knob confirm it, press knob to the next menu, choose
“Save & Exit” save the setting and exit the menu.
Fig. 12 Fig.13
er in the same
Passcode forgot and reset
If forgot passcode, turn off the power, press knob and pow
time, LCD screen will display “input code” (see Fig. 14), input passcode
“888” , the soldering iron station will reset passcode become”000”.
If need to reset passcode, please follow
Temperature passcode setting
renew your code.
Fig.14
rther more detailed informati
se visit Pro’skit website
For fu
on, plea
http://www.prokits.com.tw