3 1/2 2A Mini Digital Clamp Meter
user manual
10
lead into the V/Ω Jack.
2)
Set the rotary selector toΩ/
/
range position.
3)
Press the “SEL” button to switch to
test.
4)
Connect the red test leads to the anode and the black test
lead to the cathode of the diode for testing.
5)
Take the reading on the LCD.
TESTING TEMPERATURE
1)
Plug the black test lead into the COM jack and the red test
lead into the V/Ω Jack.
2)
Set the rotary selector to
℃
/
℉
range position.
3)
Connect the red test leads to the anode and the black test
lead to the cathode of the temperature load for testing.
4)
Take the reading on the LCD.
REPLACING THE BATTERIES
1)
If the sign
appears, it means that the batteries should be
replaced.
2)
Loosen the fixing screw of the battery cover and remove it.
3)
Replace the exhausted batteries with new one.
4)
Put the battery cover back and fix it again to its origin from.
NOTE
:
Do not reverse the poles of the batteries.
WARNING
To avoid electric shock, make sure that the test leads
have been clearly move away from the circuit under
measurement before opening the battery cover of the
meter.