background image

 

3

5.  Don’t use other unconfirmed or disapproved battery to 

replace the battery inside the meter. Only the same model or 
same electrical specification battery can be replaced. Before 
the replacement, the test lead must be removed from the 
measuring point to ensure there is no longer any signal at the 
input terminal. 

6.  When the electrical measurement is made, never let your 

body get in touch with the ground directly, and don’t touch 
uncovered metal terminal, output port, lead clamp and etc. 
where earth potential may exist. Dry clothes, rubber shoes, 
rubber cushion and other insulating material are usually used 
to keep your body insulated against the ground.   

7.  Don’t store and use it in the high-temperature, high-humidity, 

inflammable and strong magnetic field environment.   

8.  It may damage to the meter and endanger the operator’s 

safety if the voltage value beyond the permitted ultimate 
voltage value is measured. The ultimate voltage value 
permitted for measurement is marked on the instrument 
panel, and never measure the value exceeding the standard. 
Don’t input the ultimate value out of regulation in order to 
avoid electric shock and the damage to the meter.   

9.  When the test lead is inserted into the current socket, don’t 

measure any voltage for fear that the meter should be 
damaged and the operator’s safety be endangered. 

10.  Don’t try calibrating or repairing the meter. When necessary, 

only the qualified professional personnel who have had 
special training or gained approval can make it. 

11.  During measurement, the requirement of measurement 

function must be in accordance with LCD display. Please be 
sure to disconnect the line of the test lead with the measured 
object first and ensure there is no any input signal. It is 
forbidden to switch the function/range selection switch during 
measurement  

Содержание MT-1217

Страница 1: ...MT 1217 3 3 4 Autorange Digital Multimeter User s Manual 1 st Edition 2013 2013 Copyright by Prokit s Industries Co Ltd ...

Страница 2: ...s of clear reading stable performance and high reliability It can be used to measure DC voltage AC voltage DC current AC current resistance capacity frequency duty cycle diode and make on and off test Meanwhile it is available for unit symbol display automatic manual range switching automatic power off and alarm function The multimeter has high resolution and precision due to its complete function...

Страница 3: ...ve 10mA AC power line with inductive load or power line during electric fluctuation is measured please beware of electric shock 2 Prior to measurement check if the measurement function switch is at the correct position Check if the test lead is contacted reliably connected correctly and grounded well and etc in order to avoid electric shock 3 Only if the meter is used with the matched test lead wi...

Страница 4: ...d endanger the operator s safety if the voltage value beyond the permitted ultimate voltage value is measured The ultimate voltage value permitted for measurement is marked on the instrument panel and never measure the value exceeding the standard Don t input the ultimate value out of regulation in order to avoid electric shock and the damage to the meter 9 When the test lead is inserted into the ...

Страница 5: ...Symbols Warming DCV Double Insulation ACV DCA Fuse ACA Low Battery In accordance with the instruction of European Trade Union Instrument Panel Function Button Description 1 Instrument model number 2 LCD Display Display the measured data and unit 3 Function Button 3 1 Hz Frequency Duty Cycle Press this button to select the frequency or duty cycle mode The measurement mode of Voltage frequency duty ...

Страница 6: ...apacity and HFE input terminal 5 3 Voltage Diode Resistance Frequency Buzzer Input terminal 5 4 COM Current Voltage Diode Resistance Capacity Frequency Buzzer Temperature HFE Input terminal Other Functions Auto Power off During measurement the meter will automatically shut down enter sleeping mode to save power if function buttons and knob switch are not operated in 15 minutes In auto power off mo...

Страница 7: ...1 pc Technical Feature 2 1 Accuracy a reading digits at 23 5 C relative Humidity 75 One year calibration guarantee since the time dispatched from the factory 2 2 Technical Specification 2 2 1 DCV A Turn the knob switch to Range B The initiate state of the meter is in automatic range status which shows AUTO symbol C Make the test lead contacted to the testing point The voltage and polarity of the p...

Страница 8: ... which shows AUTO symbol C press Range button can select the AC measurement range D Make the test lead contacted to the testing point The voltage of the point where the red test lead is contacted will be displayed on the screen Caution 1 Don t measure voltages over 750V otherwise the meter will be damaged 2 When measuring high voltage special attention should be given to personal safety and avoid ...

Страница 9: ...the tested current value and the current polarity of the point where the red pen is contacted will be displayed on the screen simultaneously Caution 1 If OL is displayed on LCD it indicates the tested current value has exceeded the present range limit please select higher range to complete the measurement 2 The Max input value is 400mA or 10A Depending on the terminal where the red test lead is co...

Страница 10: ...y Caution 1 If OL is displayed on LCD it indicates the tested current value has exceeded the present range limit please select higher range to complete the measurement 2 The Max input value is 400mA or 10A Depending on the terminal where the red test lead is contacted The overrated current will lead to fuse melt or even damage the meter Range Accuracy Resolution 400uA 0 1uA 4000uA 1uA 40mA 10uA 40...

Страница 11: ... limit please select higher range to complete the measurement When measuring the Resistor higher than 1MΩ the instrument will take several seconds to make the reading stable It is normal when measuring the high resistor 2 When the input terminal is open circuit it will display OL 3 When measuring in line resistor be sure that the power is off and all capacitors are discharged completely Range Accu...

Страница 12: ...ment Connect the red test lead to the diode negative polarity and the black test lead to the diode positive polarity OL symbol will be displayed on the screen 5 The complete diode testing includes forward and backward measurement if the result does not meet the above it means the diode is bad 6 Press SELECT button to select the Continuity measurement mode 7 Connect the test leads to two points of ...

Страница 13: ... test leads to COM mA input terminal the screen will show capacitance parameter The relative value measurement could be conducted by pressing REL button Caution 1 Fully discharge the tested capacitor in case it damages the meter 2 When measuring in line capacitor the power should be turned off and all capacitors should be discharged completely 3 It takes about 30 seconds to input stable reading at...

Страница 14: ...cy of high voltage Then press Hz button to enter frequency measurement status 4 Don t input voltage of over 250V DC or AC peak value in case it damages the meter Range Accuracy Resolution 400Hz 0 1Hz 4kHz 1Hz 20kHz 0 5 4d 10Hz 0 1 99 9 For your reference 0 1V Input Sensitivity 0 7V RMS Overload Protection 250V DC or AC Peak Value 2 2 9 Temperature C A Rotate function switch to C gear B Insert the ...

Страница 15: ...ermocouple Nickel chromium nickel silicon banana plug WARNING DO NOT input any voltage at this range for safety 2 2 10 Triode hFE test A Turn the knob switch to HFE Range B Insert the test accessory into COM and mA terminal C Verify the type of the transistor is NPN or PNP insert the emitter basic and collector to the proper jack on test accessory Range Displaying value Test condition hFE NPN or P...

Страница 16: ...e battery shall be replaced Battery changes steps as below 5 1 Loosen the screw on the back cover that secures the battery case and remove the battery case 5 2 Remove the 9V battery and replace them with new one Although a 9V battery of any standard can be used but in order to lengthen the operation life alkaline battery should be used 5 3 Mount the battery case back and tighten the screw Precauti...

Страница 17: ...No current input Replace fuse Error value Replace battery This Instruction is subjected to change without any further notice The content of this Instruction is considered correct and in case readers find any errors and missing parts please contact the manufacturer The Company shall not be held liable for any accidents and hazards resulted from the mal operations by the user The function elaborated...

Страница 18: ...查 打開包裝箱取出儀錶 仔細檢查以下附件是否缺少或損壞 如有缺少或損壞請立即與經銷商聯繫 數字多用錶 一台 使用說明書 一本 錶棒 一付 溫度探頭 K 型熱電偶 一支 測試座 電容 晶體管 一個 三 安全注意事項 該儀錶在設計上符合 IEC1010 條款 國際電工委員會頒佈的安全標準 在 使用之前 請先閱讀安全注意事項 1 在測量直流 36V 交流 25V 以上電壓 測量 10mA 以上電流 測量帶電感 負載的交流電力線 測量電力波動期間的交流電力線時 謹防電擊 2 測量前 檢查測量功能開關是否置於正確的檔位 要檢查錶筆是否可靠 接觸 是否正確連接 是否絕緣良好等 以避免電擊 3 儀錶只有和所配備的錶棒一起使用才符合安全標準要求 如錶棒線破 損時 必須更換上同樣型號或者相同電氣規格的錶棒線 4 不要使用其他未經確認或未認可的保險管來更換儀錶內部的保險 只 能換上同樣型號或相同規格的保險管 ...

Страница 19: ...電流插座時切勿測量任何電壓以免損壞儀錶和危及操 作人員的安全 10 不要嘗試校準或維修儀錶 的確有需要時必須有專門培訓或認可的有 資格專業人員才能進行 11 在測量時功能 量程選擇開關必需置於正確的量程檔位 在轉換功能 量 程選擇開關時 請一定要先將錶棒線與被測物件斷開 確保輸入端沒任 何信號輸入 嚴禁在測量進行中轉換功能 量程選擇開關 12 當 LCD 顯示 時 請及時更換電池以確保測量精度 13 不允許在電流檔去測量電壓 14 請不要隨意改變儀錶線路 以免損壞儀錶和危及安全 15 安全符號說明 警告 直流電壓 雙重絕緣 交流電壓 直流電流 保險絲 交流電流 低電壓指示 符合歐洲工 會指令 四 儀錶面板及按鍵功能說明 1 儀錶型號 2 液晶顯示器 顯示儀錶測量的數值及單位 3 功能按鍵說明 3 1 Hz 頻率 占空比 交流電壓位 觸發此鍵 可進行頻率 占 空比測量 3 2 Range 量...

Страница 20: ...他功能 自動關機 在測量過程中 功能按鍵和撥盤開關在 15 分鐘內均無動作時 儀錶會 自 動關機 休眠狀態 以節約電能 在自動關機狀態下 按動功能鍵或是 轉動撥盤開關 儀錶會 自動開機 工作模式 六 特性 1 一般特性 1 1 顯示方式 液晶顯示 1 2 最大顯示 3999 3 3 4 位元 自動極性和單位顯示 1 3 測量方式 雙積分式 A D 轉換 1 4 轉換速率 約每秒 3 次 1 5 過量程顯示 顯示 OL 1 6 低電壓顯示 符號出現 1 7 工作環境 0 40 相對濕度 80 1 8 相對溫度 0 50 相對濕度 80 1 9 電源 一隻 9V 電池 NEDA1604 6F22 或同等型號 1 10 體積 尺寸 182 90 46mm 長 寬 高 1 11 重量 約 320 g 不包括 9V 電池 1 12 附件 說明書一本 10A 錶棒一付 K 型熱電偶一支 測試座一個 2...

Страница 21: ...在螢幕 上 注意 1 測量電壓切勿超過 1000V 超過則有損壞儀錶電路的危險 2 當測量高電壓電路時 千萬注意避免人體觸及高壓電路 注意人身安全 20 量程 準確度 分辨力 400mV 100uV 4V 1mV 40V 10mV 400V 0 5 4d 100mV 1000V 1 0 6d 1V 輸入阻抗 10MΩ 超載保護 1000V 直流或交流峰值 2 3 2 交流電壓 ACV 1 將黑錶棒插入 COM 插孔 紅錶棒插入 插孔 2 將旋鈕開關轉至 檔 初始為自動量程狀態 顯示 AUTO 符號 3 按動 SELECT 鍵選擇可手動選擇測量量程 4 將測試錶棒接觸測試點 紅錶棒接的該點電壓顯示在螢幕上 注意 1 測量電壓切勿超過 750V 如超過 有損壞儀錶電路的危險 2 當測量高電壓電路時 千萬注意避免人體觸及高壓電路 注意人身安全 ...

Страница 22: ...流值及紅色錶棒點的 電流極性將同時顯示在螢幕上 注意 1 如 LCD 顯示 OL 表明已超過量程範圍 需將量程開關轉至較高 一檔 2 最大輸入電流為 400mA 或者 10A 視紅錶棒插入位置而定 超過額 定的電流會將保險絲熔斷 甚至損壞儀錶 量程 準確度 分辨力 400uA 0 1uA 4000uA 1uA 40mA 10uA 400mA 1 0 10d 100uA 4A 1 2 10d 10mA 10A 1 2 10d 10mA 最大測量壓降 滿量程 mA 為 0 4V A 為 100mV 最大輸入電流 10A 不超過 15 秒 超載保護 0 4A 250V 自恢復保險絲 10A 250V 保險管 2 3 4 交流電流 ACA 1 將黑錶棒插入 COM 插孔 紅錶棒插入 mA 插孔 最大為 400mA 或插入 10A 插孔中 最大為 10A 2 將旋鈕開關轉至電流檔 按動 SELECT...

Страница 23: ...mV 最大輸入電流 10A 不超過 15 秒 超載保護 0 4A 250V 自恢復保險絲 10A 250V 保險管 頻率回應 10A 量程為 50 200 Hz 2 3 5 電阻 Ω 1 將黑錶棒插入 COM 插孔 紅錶棒插入 插孔 A 將旋鈕開關轉至 Ω 檔 兩錶棒跨接在被測電阻上 B 如果測量阻值小的電阻 應先將錶棒短路 測得引線電阻 然後在 實測中減去 注意 1 如 LCD 顯示 OL 表明已超過量程範圍 需將旋鈕開關轉至較高 一檔 當測量電阻超過 1MΩ 以上時 讀數幾秒之後才能穩定 這在 測量高阻時是正常的 2 當輸入端開路時 則顯示 OL 3 測量線上電阻時 要確認被測電路所有電源已關閉及所有電容都已完 全放電 才可進行 量程 準確度 分辨力 400Ω 0 8 5d 0 1Ω 4kΩ 1Ω 40kΩ 10Ω 400kΩ 100Ω 4MΩ 0 8 4d 1kΩ 40MΩ 1 2 ...

Страница 24: ...測試包括正反向測量 如果測試結果與上述不符 說明 二極體是壞的 F 按動 SELECT 鍵選擇通斷測量方式 G 將錶棒連接到待測線路的兩點 如果內置蜂鳴器發聲 則兩點之間電 阻值低於約 50Ω 則內置蜂鳴器發聲 量程 顯示值 測試條件 二極體正向壓降 正向直流電流 0 5mA 反向電壓約 1 5V 蜂鳴器發聲長響 測 試兩點阻值約 50Ω 開路電壓約 0 5V 超載保護 250V 直流或交流峰值 警告 為了安全在此量程禁止輸入電壓值 2 3 7 電容 F 1 將旋鈕開關轉至 檔 2 或將檔位設置在 Ω 檔 按動 SELECT 鍵選擇電容測量方式 3 將黑錶棒插入 COM 插孔 紅錶棒插入 mA 插孔 4 用測試錶棒 注意紅錶棒極性為正極 將被測電容接入 COM 和 mA 輸入端 螢幕將顯示電容容量 按動 REL 鍵可進行相對 值測量 注意 1 對被測電容應完全放電 以防止損壞儀錶 2 測量...

Страница 25: ...Hz 按鍵進入頻率測量 狀態 4 禁止輸入超過 250V 直流或交流峰值的電壓 以免損壞儀錶 程量 準確度 分辨力 400Hz 0 1Hz 4kHz 1Hz 20kHz 0 5 10d 10Hz 0 1 99 9 僅供參考 0 1V 輸入靈敏度 0 7V 有效值 超載保護 250V 直流或交流峰值 2 3 9 溫度 C 1 將旋鈕開關轉至 檔 2 將熱電偶感測器的冷端 自由端 負極 黑色插頭 插入 COM 插 孔 正極插入 mA 插孔中 熱電偶的工作端 測溫端 置於待測物 上面或內部 可直接從螢幕上讀取溫度值 讀數為攝氏度 注意 1 當輸入端開路時 則顯示常溫 2 請勿隨意更換測溫感測器 否則將不能保證測量準確度 3 嚴禁在溫度檔測量電壓 量程 準確度 分辨力 20 1000 C 400 C 1 0 5d 400 C 1 5 15d 1 C 感測器 K 型熱電偶 鎳鉻 鎳硅 香蕉插頭 警 ...

Страница 26: ...應取出電池 防止電池漏液腐蝕儀錶 5 注意 9V 電池使用情況 當螢幕顯示出 符號時 應更換電池 步驟如下 5 1 卸下固定電池盒的螺絲 取出電池盒 5 2 取出 9V 電池 換上一個新的電池 雖然任何標準 9V 電池都可使用 但為加長使用時間 最好使用鹼性電池 5 3 裝回電池盒 鎖緊螺絲 注意 1 不要將 1000V 直流或交流峰值電壓接入 2 不要在電流檔 電阻檔 二極體檔和蜂鳴器檔上 測量電壓值 3 在電池沒有裝好或後蓋沒有上緊時 請不要使用此錶 4 在更換電池或保險絲前 請將測試錶棒測試點移開 並關機 八 故障排除 如果您的儀錶不能正常工作 下面的方法可以幫助您快速解決一般問題 如果故障仍排除不了 請與維修中心或經銷商聯繫 故障現象 檢 查 部 位 及 方 法 沒顯示 電源未接通 或更換電池 符號出現 更換電池 顯示誤差大 更換電池 本說明書如有改變 恕不另行通知 本說明書的內容...

Страница 27: ...是維修性質之服務 則酌收檢修工時費 用 若有零件需更換 則零件費另計 產品保固說明 保固期限內 如有下列情況者 維修中心則得酌收材料成本或修理費 由 本公司維修人員判定 對產品表面的損傷 包括外殼裂縫或刮痕 因誤用 疏忽 不當安裝或測試 未經授權打開產品修理 修改 產品或者任何其他超出預期使用範圍的原因所造成的損害 因事故 火災 電力變化 其他危害 或自然災難所造成的損害 非服務保證內容 機件本體外之消耗品 如電池 等消耗品 機件本體之外之附配件 如耳機麥克風 電源供應器 記憶卡 CD 等附配件 超過保證期限之檢修或服務 雖未更換零件 將依公司保固維修政策酌 收服務費 服務電話 0755 83692415 83692986 83246594 83247554 服務傳真 0755 83692143 26 ...

Страница 28: ... 2013 Prokit s Industries Co LTD All rights reserved 2013001 T 27 ...