background image

 

 

 

Proboil descaler guide v1-0a 

 

4.

 

If the boiler is only lightly calcified (scaled) use 1 x 200ml descaler liquid bottle, if the boiler is heavily calcified use 2 
x 200ml descaler bottles, if you are unsure we recommend you use 2 x 200ml bottles. 
 

5.

 

Shake the bottle gently then carefully cut the top of the bottle nozzle open with a pair of scissors.  
 

6.

 

Carefully and slowly empty the contents of the descaler bottle into the boiler vent (A7), if access for the bottle 
nozzle is difficult a plastic funnel can be used to help. 

⚠ 

Take care during this step as steam is expected to exit the vent (A7) as the descale solution is added. 

 

7.

 

Take note of the time and wait for 

no longer than 30 minutes

 

maximum

 for the descaler liquid to work. It is normal 

for an odour to be present during this time. 
 

8.

 

Firmly reattach the flexible connector (B9) to the boiler vent (A7). 

Wear suitable gloves to ensure your safety.

 

 

9.

 

Switch on the PROBOIL at the front control panel (see user guide for more details). 
 

10.

 

Dispense the entire contents of the boiler using the key fob, before immediately switching off the PROBOIL at the 
front control panel (see 

using the product

 for more details). 

 

11.

 

Drain the remaining water from the tank (see 

draining section

 of the user guide for more details). 

 

12.

 

Close the drain (A12). 

 

13.

 

Switch on the PROBOIL at the front control panel (see 

using the product

 in user guide for more details). 

 

14.

 

Allow the PROBOIL to fully fill and heat to back to a maximum temperature of 80°C this process will take a minimum 
of 20

 

minutes, again it is normal for an odour to be present during this time. 

 

15.

 

Repeat steps 10-12 draining the boiler entirely. 

 

16.

 

Disconnect and stow the drain pipe (A14) & connector (A13) securely replace the drain cover (A11) and screw (A10). 
 

17.

 

If required, adjust the temperature to your previous preference (see 

user guide

 for more details). 

 

 

Should any taste or odour persist in normal use after flushing the unit twice, repeat the flushing procedure as 

described in steps 10 to 14 until it subsides. 

 

 

In the event that the boiler is heavily scaled and following the above steps did not remove all the scale, repeat 

the complete descaling procedure. If further descaling does not clear any descale warning on the PROBOIL, please 
contact the service agent using the labelled contact details on top of the boiler.  

 

 

If misplaced you can download a copy of the full user guide at 

www.proboil.co.uk

 

Отзывы: