background image

________________________________________________________________________________ 

15 

 Stationary lifter (90/125/130/175/225P) 

DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY

 

Manufacturer 

Pronomic AB  
Box 5504 
192 05 Sollentuna 
Sweden 

Model 

Parts for stationary lifter  

 90P    

 125P    

 130P    

 175P    

 225P

 

Serial number 

 

Static load test 

 

 
Applied EC directives: 

2006/42/EC 

Machinery Directive 

2004/108/EC 

EMC Directive 

 
Applied standards: 

EN ISO 12100-1:2010 

Safety of machinery 

 General principles for design. Risk assessment and risk 

reduction 

SS-EN 349+A1:2008 

Safety of machinery - Minimum gaps to avoid crushing of parts of the human body 

 
We hereby declare that the above-referenced partly completed machine, installed and maintained after 
instructions provided in this manual, is in conformity with stated directives and standards. 

The partly completed machinery must not be put into service until the final machinery into which it is to 
be incorporated has been declared in conformity with the provisions of this Directive. 

Sollentuna, 2015-01-20 

 

…………………………………………………………

 

Joakim Stannow, PRONOMIC AB

 

______________________________________________________________________________ 
The partly completed machine has been modified and/or equipped with attachments as follows: 

……………………………………………………………………………………………………………………………………………………………………….…….

 

 

……………………………………………………………………………………………………………………………………………………………………….…….

 

After modification a supplementary risk analysis has been performed and the partly completed machine is 
certified to be in conformity with the directives and standards above. 
 

…………………………………………………………………………………………

 

Place, date

 

 

…………………………………………………………………………………………

 

Name

 

…………………………………………………………………………

 

Company

 

Содержание 125P

Страница 1: ...Parts for Stationary lifter 90P 125P130P 175P 225P Original instructions ...

Страница 2: ... have any questions Please contact the distributor or the manufacturer Pronomic AB Visiting address Domherrevägen 15 192 55 Sollentuna Sweden Postal address Box 5504 192 05 Sollentuna Sweden Phone 46 8 544 706 60 Fax 46 8 544 706 70 E mail info pronomic se www pronomic se R150415 ...

Страница 3: ... Loading and unloading 6 5 Maintenance 7 5 1 Every day 7 5 1 1 General 7 5 2 Every year or when needed 7 5 2 1 Cleaning 7 5 2 2 Electrical connections 7 5 2 3 Wear of machine parts 7 5 2 4 Nuts and bolts 7 5 2 5 Lift column 7 5 3 Trouble shooting 9 6 Technical specifications 9 7 Load diagram 10 7 1 90P Setup 10 7 2 125P Setup 11 7 3 130P Setup 12 7 4 175P Setup 13 7 5 225P Setup 14 DECLARATION OF ...

Страница 4: ...is only to be used indoors in well lit environments on level surfaces Additional technical documentation can be ordered from Pronomic 1 1 Warranty The warranty is valid for one 1 year from the date of delivery for defects in material and manufacturing For the warranty to be valid maintenance must have been carried out in accordance with this manual The warranty does not cover normal maintenance se...

Страница 5: ...________________________________________________________________________________ 2 Stationary lifter 90 125 130 175 225P 1 2 4 3 5 ...

Страница 6: ... At least 30mm of thread is needed inside of the cross member Do not tighten to hard use 15 Nm 2 In position B in the picture above Screw bars should be positioned with the lowest screw at least 245mm from the bottom end of the column For 90 125 130P the distance should be at least 145mm from bottom end of the column The screw bars should be fastened with 4 M8 nyloc nuts against the structure 2 nu...

Страница 7: ...erform a static load test with 1 25 x the maximum load Move the load carrier to the middle of the column and apply the load 8 The stationary lifter is now read for use 2 1 Disassembly and scrapping To disassemble the stationary lifter follow the instructions in section Assembly but in reverse order When the stationary lifter is due for scrapping the machine should be handed in to a recycling centr...

Страница 8: ...s dangerous It should not be exposed to splashed or running water Turn of the power pack when not in use 4 Safety and Limitations Use the protective equipment e g protective footwear required to handle the goods The stated maximum load may not be exceeded The stationary lifter must not be used for lifting people Note the crush hazard between the load carrier and fixed objects or floor when raising...

Страница 9: ...transport to avoid the risk of damage 4 3 Loading and unloading The user is responsible for ensuring that the stationary lifter is loaded correctly The centre of gravity of the goods should always be centred on the load carrier and as close to the column as possible for maximum stability The load carrier should be positioned at the correct height before loading unloading To allow a good working po...

Страница 10: ...r a load test should be performed see section Assembly 5 1 Every day 5 1 1 General Keep the lifter clean and avoid dirt or fluids from reaching past brushes to lift screw and slide 5 2 Every year or when needed 5 2 1 Cleaning Clean the lifter using detergent suitable for painted surfaces aluminium and stainless steel Follow the instructions on the detergent Wipe the lifter dry after cleaning Do no...

Страница 11: ...onary lifter 90 125 130 175 225P Put the lift screw back and tighten the screws Check the coupling by making sure the sleeve and the hub located inside the column and inside the cross member are intact and in working order Put the lift column back and perform load test see section Assembly ...

Страница 12: ... taken Please contact service technician or Pronomic If the load carrier does not move at all or very slowly Verify that the maximum load is not exceeded Check the AC DC converter If the lift trolley sounds strange Make sure the stationary lifter is correctly assembled see section Assembly See section Maintenance 6 Technical specifications Model 90P 125P 130P 175P 225P Max load 90kg 125kg 130kg 17...

Страница 13: ...________________________________________________________________________________ 10 Stationary lifter 90 125 130 175 225P 7 Load diagram 7 1 90P Setup ...

Страница 14: ...________________________________________________________________________________ 11 Stationary lifter 90 125 130 175 225P 7 2 125P Setup ...

Страница 15: ...________________________________________________________________________________ 12 Stationary lifter 90 125 130 175 225P 7 3 130P Setup ...

Страница 16: ...________________________________________________________________________________ 13 Stationary lifter 90 125 130 175 225P 7 4 175P Setup ...

Страница 17: ...________________________________________________________________________________ 14 Stationary lifter 90 125 130 175 225P 7 5 225P Setup ...

Страница 18: ...the human body We hereby declare that the above referenced partly completed machine installed and maintained after instructions provided in this manual is in conformity with stated directives and standards The partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of this Directive So...

Страница 19: ...nary lifter 90 125 130 175 225P INSTALLATION PRONOMIC AB is not responsible for installation of the partly completed machine The partly completed machine has been installed according to the instructions in this manual and the safety and limitations has been considered Place date Name Company ...

Страница 20: ...________________________________________________________________________________ 17 Stationary lifter 90 125 130 175 225P ...

Отзывы: