SECTION 5
Pronar T900
5.43
5.14
TROUBLESHOOTING
TABLE 5.8
Troubleshooting
FAULT
CAUSE
REMEDY
Brake system pneumatic
conduit not connected
Connect brake conduits.
Damaged pneumatic
system connection conduits
Replace
Leaking connections
Tighten, replace washers or seal
set
Parking brake applied
Release parking brake
Problem with moving off
Damaged loosening-parking
valve or main valve
Check the valves. Repair or
replace any damaged components
Excessive bearing
slackness
Check slackness and adjust if
needed
Noise in axle hubs
Damaged bearings
Change bearing together with
sealing ring
Incorrectly adjusted main
brake
Regulate positions of expander
arms
Excessive heating of axle
hubs
Worn brake linings
Change brake shoes
Incorrectly connected
hydraulic system conduits
Check and possibly correct
The front wall can not be
shifted or raised
Damaged quick couplers of
hydraulic system conduits
Replace quick couplers
Damaged or non-adjusted
limit valve of hydraulic
system
Check, adjust or possibly replace
The front wall can not be
shifted or raised
Improper hydraulic oil
viscosity
Check oil quality, make sure that
the oil in both machines is of the
same type. If necessary change
oil in tractor or in trailer.
Содержание T900
Страница 2: ......
Страница 6: ......
Страница 11: ...SECTION 1 BASIC INFORMATION ...
Страница 25: ...SECTION 2 SAFETY ADVICE ...
Страница 40: ...Pronar T900 SECTION 2 2 16 FIGURE 2 3 Decal locations ...
Страница 41: ...SECTION 3 DESIGN AND OPERATION ...
Страница 68: ...Pronar T900 SECTION 3 3 28 ...
Страница 69: ...SECTION 4 CORRECT USE ...
Страница 96: ...Pronar T900 SECTION 4 4 28 ...
Страница 97: ...SECTION 5 MAINTENANCE ...
Страница 129: ...SECTION 5 Pronar T900 5 33 FIGURE 5 13 Lubrication points ...
Страница 130: ...Pronar T900 SECTION 5 5 34 FIGURE 5 14 Lubrication points ...
Страница 141: ...NOTES ...
Страница 142: ... ...
Страница 143: ...ANNEX A WALL EXTENSION INSTALLATION MANUAL ...
Страница 150: ...Pronar T900 WALL EXTENSION INSTALLATION MANUAL A 8 ...
Страница 153: ......