SECTION 5
Pronar PT510
5.17
Visual inspection of the system
•
Conduct inspection of system at the same time as when checking tightness.
ATTENTION
Repair, exchange or regeneration of pneumatic system components may only be
performed in a specialised workshop.
5.3.3 CLEANING THE AIR FILTERS
Depending on trailer working conditions, but not less than once in three months, take out and
clean air filter elements, which are located in pneumatic system connection conduits. Filter
elements are used many times and are not subject to change unless they are mechanically
damaged.
FIGURE 5.7
Air filter
(1) securing slide lock, (2) air filter cover