5
See operating voltage range in cl. 5.2. Avoid supply of increased voltage.
Ensure a reliable electric contact. To prevent short-circuit, insulate places of
connection.
White
– positive pole of the power supply;
Black
– negative pole of the power supply;
Reverse voltage supply does not ensure lock operability, but it does not cause its failure.
Example of the lock connection to the remote control system Promix-RDS.
7.
FEATURES OF INSTALLATION AND
OPERATION
1) The possibility of using the locks for access restriction to retail and office furniture and the
place of installation are determined by
the installation organization
on the basis of the
design features and the mounting method, furniture criticality level, the purpose of the access
restriction regime and other factors (the presence of security providers, video surveillance,
etc.).
2) To prevent door deformation, it is recommended to install the lock in the area of the handle.
3) When mounting the lock and the latch, it is necessary to ensure their coaxial alignment within
the latch free movement allowance.
4) When the door is closed, the latch must be inserted all the way into the lock. The lock may fail
to open when the door is in “tension” condition, i.e., an external force for opening is applied.
7.1 EMERGENCY OPENING
There is an emergency opening lever
next to the power supply wire output. For
mechanical unlocking of the lock, pull the
lever and then open the door.
Lock
Controller Promix-CR.RX
Promix-CR.TX
RCU
~220 V
Emergency opening lever
Pull