To Migrate an existing disk array:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array icon.
4.
From the dropdown menu the Background Activities tab, select
Start
Migration
.
5.
Highlight physical drives you want in the disk array from the Available list and
press the >> button to move them to the Selected list.
You can also double-click them to move them.
6.
When you are done, click the
Next
button.
7.
Select a new RAID Level, if desired.
8.
To expand the disk array's capacity, check the Expand Capacity box.
9.
If you checked the Expand Capacity box, enter a number into the Capacity
field and select the appropriate unit of measure (MB, GB, TB).
10. Under Capacity Usage, highlight the logical drive whose RAID level you want
to change or whose capacity you want to expand.
11. Click the
Update
button.
The logical drive changes to reflect your choices.
12. Update other logical drives using the same method.
13. When you are done making the changes, click the
Next
button.
14. Click the
Submit
button to begin Migration.
To set Migration priority, see “Making Background Activity Settings” on page 51.
Rebuilding a Disk Array
When you rebuild a disk array, you are actually rebuilding the data on a
replacement physical drive.
Rebuilding Automatically
Normally, a disk array would rebuild itself using a hot disk drive, after going
Critical. However, if the Auto Rebuild function is disabled or no spare drives are
available, you must initiate the procedure.
To enable Auto Rebuild, see “Making Background Activity Settings” on page 51.
To create a spare drive, see “Creating a Spare Drive” on page 126.
For more information, see “Hot Spare Drive(s)” on page 234.
Содержание VTRAK M210i
Страница 1: ...VTRAK M610i M310i M210i Product Manual Version 0 9 ...
Страница 14: ...VTrak M610i M310i M210i Product Manual xiv ...
Страница 22: ...VTrak M610i M310i M210i Product Manual 8 ...
Страница 53: ...Chapter 4 Management with WebPAM PROe 39 Figure 1 The WebPAM PROe log in screen ...
Страница 144: ...VTrak M610i M310i M210i Product Manual 130 ...
Страница 212: ...VTrak M610i M310i M210i Product Manual 198 ...
Страница 232: ...VTrak M610i M310i M210i Product Manual 218 ...
Страница 256: ...VTrak M610i M310i M210i Product Manual 242 ...
Страница 296: ...VTrak M610i M310i M210i Product Manual 282 ...
Страница 318: ...VTrak M610i M310i M210i Product Manual 304 ...