
VTrak M610i, M310i, M210i Product Manual
234
capacity or larger. However, the Capacity Coercion feature permits the
installation of a replacement drive that is slightly smaller (within 1 gigabyte) than
the remaining working drive. For example, the remaining working drives can be
80.5 GB and the replacement drive can be 80.3, since all are rounded down to
80 GB. This permits the smaller drive to be used.
Without Capacity Coercion, the controller will not permit the use of a replacement
physical drive that is slightly smaller than the remaining working drive(s).
Initialization
Initialization is done to logical drives after they are created from a disk array.
Initialization sets all data bits in the logical drive to zero. The action is useful
because there may be residual data on the logical drives left behind from earlier
configurations. For this reason, Initialization is recommended for all new logical
drives. See “Initializing a Logical Drive” on page 121 (WebPAM PROe) or
page 160 (CLU).
Hot Spare Drive(s)
A hot spare is a disk drive that is connected to the disk array system but is not
assigned as a member of the disk array. In the event of the failure of a drive
within a functioning fault tolerant disk array, the hot spare is activated as a
member of the disk array to replace a drive that has failed.
VTrak will replace a failing disk drive in a disk array with an unassigned drive, if
one is available. The unassigned drive is not part of any disk array. Such a drive
is called a
hot spare
drive. There are two types:
•
Global
– An unassigned disk drive available to any disk array on the VTrak.
•
Dedicated
– An unassigned disk drive that can only be used by a specified
disk array.
The hot spare policy function lets you select whether a disk array will access any
unassigned disk drive or a designated drive in the event of disk drive failure. See
“Managing Spare Drives” on page 125 (WebPAM PROe) or page 176 (CLU) for
information on how to make this setting.
The spare drive effectively takes the place of the failed drive and the RAID
system immediately begins to rebuild data onto the drive. When the rebuild is
complete, the disk array is returned to fault tolerant status.
Caution
When you initialize a logical drive, all the data on the logical drive
will be lost. Backup any important data before you initialize a
logical drive.
Содержание VTRAK M210i
Страница 1: ...VTRAK M610i M310i M210i Product Manual Version 0 9 ...
Страница 14: ...VTrak M610i M310i M210i Product Manual xiv ...
Страница 22: ...VTrak M610i M310i M210i Product Manual 8 ...
Страница 53: ...Chapter 4 Management with WebPAM PROe 39 Figure 1 The WebPAM PROe log in screen ...
Страница 144: ...VTrak M610i M310i M210i Product Manual 130 ...
Страница 212: ...VTrak M610i M310i M210i Product Manual 198 ...
Страница 232: ...VTrak M610i M310i M210i Product Manual 218 ...
Страница 256: ...VTrak M610i M310i M210i Product Manual 242 ...
Страница 296: ...VTrak M610i M310i M210i Product Manual 282 ...
Страница 318: ...VTrak M610i M310i M210i Product Manual 304 ...