VTrak J830s, J630s Product Manual
36
Setting Thermal Management
Thermal Management monitors enclosure and I/O module temperature and
adjusts fan speeds for proper cooling. Promise recommends that you set
Thermal Management to enabled.
To enable Thermal Management:
At the cli> prompt, type enclosure -a mod -s "thermalmanager=1" and press
Enter.
For this command, 1 enables and 0 disables.
Setting Shutdown
When enabled, Shutdown automatically shuts down the VTrak 30 seconds after
the enclosure or I/O module reaches critical temperature to avoid damage from
overheating. Promise recommends that you set Shutdown to enabled.
To enable Shutdown:
At the cli> prompt, type enclosure -a mod -s "allowshutdown=1" and press
Enter.
For this command, 1 enables and 0 disables.
Setting Minimum Fan Speed
Minimum Fan Speed specifies the minimum fan speed when the enclosure or I/O
module reaches warning temperature.
To set the minimum fan speed to medium high:
At the cli> prompt, type enclosure -a mod -s "minfanspeed=3" and press Enter.
For this command:
•
1 means low
•
2 means medium-low
•
3 means medium-high
•
4 means high
The actual speed depends on the fan manufacturer.